Solid State Relays

G3NA

The reliable choice for Hockey-puck-style Solid State Relays. Available in a Wide Range of Currents.

Model Number Structure
Model Number Legend
Ordering Information
List of Models
Isolation
Zero cross
function
Indicator
Applicable output load
(See note 1.)
Rated input
voltage
Model
Phototriac
Yes
Yes
5 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-205B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-205B-UTU AC100-240
Phototriac
10 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-210B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-210B-UTU AC100-240
Phototriac
20 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-220B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-220B-UTU AC100-240
Phototriac
25 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-225B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-225B-UTU AC100-240
Phototriac
40 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-240B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-240B-UTU AC100-240
Phototriac
50 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-250B-UTU DC5-24
Photocoupler
100 to 240 VAC
G3NA-250B-UTU AC100-240
Phototriac
75 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-275B-UTU-2 DC5-24
Photocoupler
100 to 240 VAC
G3NA-275B-UTU-2 AC100-240
Phototriac
90 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC
G3NA-290B-UTU-2 DC5-24
Photocoupler
100 to 240 VAC
G3NA-290B-UTU-2 AC100-240
10 A at 200 to 480 VAC
5 to 24 VDC
G3NA-410B-UTU DC5-24
100 to 240 VAC
G3NA-410B-UTU AC100-240
20 A at 200 to 480 VAC
5 to 24 VDC
G3NA-420B-UTU DC5-24
100 to 240 VAC
G3NA-420B-UTU AC100-240
25 A at 200 to 480 VAC
5 to 24 VDC
G3NA-425B-UTU-2 DC5-24
100 to 240 VAC
G3NA-425B-UTU-2 AC100-240
40 A at 200 to 480 VAC
5 to 24 VDC
G3NA-440B-UTU-2 DC5-24
100 to 240 VAC
G3NA-440B-UTU-2 AC100-240
50 A at 200 to 480 VAC
5 to 24 VDC
G3NA-450B-UTU-2 DC5-24
100 to 240 VAC
G3NA-450B-UTU-2 AC100-240
75 A at 200 to 480 VAC
5 to 24 VDC
G3NA-475B-UTU-2 DC5-24
100 to 240 VAC
G3NA-475B-UTU-2 AC100-240
90 A at 200 to 480 VAC
5 to 24 VDC
G3NA-490B-UTU-2 DC5-24
100 to 240 VAC
G3NA-490B-UTU-2 AC100-240
---
10 A at 5 to 200 VDC
5 to 24 VDC
G3NA-D210B-UTU DC5-24
100 to 240 VAC
G3NA-D210B-UTU AC100-240
*All models are certified by UL, CSA, and TÜV.
Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in Engineering Data on Data Sheet.

         2. Loss time increases under 75 VAC. (Refer to Data Sheet.) Confirm operation with the actual load.
Accessories (Order Separately)
One-touch Mounting Plates
Model
R99-12 FOR G3NA
Heat Sinks
DIN-track Mounting
Model
Applicable SSR
Y92B-N50
G3NA-205B-UTU, G3NA-210B-UTU, G3NA-D210B-UTU, G3NA-410B-UTU, G3NE-210T(L)-US
Y92B-N100
G3NA-220B-UTU, G3NA-420B-UTU, G3NE-220T(L)-US
Y92B-N150
G3NA-225B-UTU, G3NA-240B-UTU, G3NA-425B-UTU-2, G3NA-440B-UTU-2
Y92B-P250
G3NA-250B-UTU, G3NA-450B-UTU-2
Y92B-P250NF
G3NA-275B-UTU-2, G3NA-290B-UTU-2, G3NA-475B-UTU-2, G3NA-490B-UTU-2
Screw Mounting
Model
Applicable SSR
Y92B-A100
G3NA-205B-UTU, G3NA-210B-UTU, G3NA-D210B-UTU, G3NA-220B-UTU,
G3NA-410B-UTU, G3NA-420B-UTU
Y92B-A150N
G3NA-225B-UTU, G3NA-240B-UTU, G3NA-425B-UTU-2, G3NA-440B-UTU-2
Y92B-A250
G3NA-440B-UTU-2