Relay Terminal (Vertical Type)

G70D-VSOC16 / VFOM16

Easy-to-use, Space-saving 16-point Output Block

Ratings
Relay Specifications
The following specifications apply to G6D Relays mounted in a G70D Relay Terminal and not the G6D Relay itself.
Coil Ratings (per G6D Relay)
Rated voltage
24 V DC
Rated current
10.5 mA
Coil resistance
2,880 Ω
Must-operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
130% of rated voltage
Power consumption
Approx. 200 mW
Note: 1. The must-operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
         2. Rated current and coil resistance were measured at a coil temperature of 23° C with a tolerance of ±10%.

         3. Operating characteristics were measured at a coil temperature of 23° C.

         4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating

             power supply. There is no continuous allowance.

         5. The rated current includes the terminal’s LED current.
Contact Ratings (per G6D Relay)
Load
Resistive load (cosφ = 1)
Rated load
3 A at 250 V AC, 3 A at 30 V DC
Rated carry current
5 A *1
Max. switching voltage
250 V AC, 30 V DC
Max. switching current
5 A
Max. switching capacity
(reference value)
1,250 VA, 150 W
Min. permissible load
(reference value) *1
5 V DC, 1 mA
Endurance
Electrical
100,000 operations min. (under and at the rated load at 1,800 operations/h)
Mechanical
20,000,000 operations min. (at 18,000 operations/h)
*1. Up to 5 A can be carried when 8 or fewer outputs are ON.
*2. This value is for a switching frequency of 120 times per minute.
Power MOSFET Relay Specifications
The following values apply to G3DZ Relays mounted in a G70D Output Block and not the G3DZ Relay itself.
Input (per G3DZ Power MOSFET Relay)
Rated voltage
24 V DC
Operating voltage
19.2 to 28.8 V DC
Voltage level
Must-operate
19.2 V DC max.
Must release
1 V DC min.
Input impedance
4 kΩ±20%
Rated current
8.2 mA±20%
Note: The rated current includes the current consumption of the operation indicator.
Output (per G3DZ Power MOSFET Relay)
Load voltage
3 to 264 V AC, 3 to 125 V DC
Load current
100 μA to 0.3 A
Inrush current
6 A (10 ms)
Characteristics
Item
G70D-VSOC16
G70D-VFOM16
Relay outputs
Power MOSFET Relay outputs
Contact configuration
16 points (SPST-NO × 16)
Contact structure
Single
---
Contact resistance
100 mΩ max. *1
---
Isolation method
---
Photocoupler
Must-operate time
10 ms max. *2
10 ms max.
Release time
10 ms max. *2
15 ms max.
Output ON-resistance
---
2.4 Ω max.
Open-circuit leakage current
---
10 μA max. (at 125 V DC)
Max. switching frequency
Mechanical: 18,000 operations/h
Rated load: 1,800 operations/h
---
Insulation resistance
100 MΩ min. (at 500 V DC)
Dielectric strength
2,000 V AC for 1 min between coil and
contact
2,000 V AC for 1 min between input and
output terminals
Noise immunity
Power input (normal mode): 600 V for 10 min with a pulse width of 100 ns to 1 μs
Power input (common mode): 1.5 kV for 10 min with a pulse width of 100 ns to 1 μs

Input cable (coiling): 1.5 kV for 10 min with a pulse width of 100 ns to 1 μs

Unit body (coiling): 600 V for 10 min with a pulse width of 100 ns to 1 μs
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.5-mm amplitude (1.0-mm double)
Malfunction: 10 to 55 to 10 Hz, 0.375-mm amplitude (0.75-mm double)
Shock resistance
Destruction: 300 m/s2, Malfunction: 100 m/s2
Operating voltage range
24 V DC +10%/-15%
Current consumption
Approx. 170 mA at 24 V DC *3
Approx. 125 mA at 24 V DC *4
Cable length
Between block and controller: 5 m max. (reference value for AWG28)
Between block and external device: Dependent on load
LED color
Operation indicator: orange
Coil surge absorber
Diode (600 V, 1 A)
Ambient temperature
Operating: -25 to 55°C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Mounting strength
No damage when 49 N pull load was applied for 1 s in all directions (except for 9.8 N in
direction of rail)
Terminal strength
Tightening torque: 0.78 to 118 N·m
Pull strength: 49 N for 1 min
Weight *5
Approx. 280 g
Note: These values are initial values.
*1. Measurement: 1 A at 5 V DC

*2. Ambient temperature: 23°C

*3. Current consumption is when all points are ON and includes G6D Relay coil current bu
t does not include any external load current.
*4. Current consumption is when all points are ON and includes G3DZ input current but does not include any external load current.

*5. The Unit weighs approximately 315 g with the Expansion Terminal Block mounted.