I/O Relay Terminal

G70V

Our Value Design Products Increase the Value of Your Control Panels. I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor.

Specifications
Coil Ratings (Common to Input/Output per Relay)
Rated voltage
(V)
Rated
current

(mA)
Coil
resistance

(Ω)
Must
operate of

rated voltage
Must
release of rated

voltage
Maximum
voltage of rated

voltage
Power
consumption

(mW)
24 VDC
13.3
1575
80% max.
10% min.
110%
Approx. 280
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±15% for coil resistance.

2. The operating characteristics are measured at a coil temperature of 23°C.

3. The value for maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’s operating power supply. Continuous operation at this voltage is not within product specifications.

4. The rated current includes the current for the indicators on the I/O Relay Terminal.
Contact Ratings (G2RV-1-S-G I/O Relay)
Item
For input
For output
Resistive load
(cosφ=1)
Resistive load
(cosφ=1)
Inductive load
(cosφ=0.4 L/R=7 ms)
Rated load
50 mA at 30 VAC
50 mA at 36 VDC
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
Rated carry current
50 mA
6 A/point, 10 A/common
Max. switching voltage
30 VAC, 36 VDC
250 VAC, 125 VDC
Max. switching current
50 mA
6 A/point, 10 A/common
Maximum switching capacity
---
1,500 VA
180 W
500 VA
60 W
Error rate
(reference value) *
1 mA at 100 mVDC
10 mA at 5 VDC
 
Electrical endurance
5,000,000 operations min.
NO contacts: 70,000 operations min.
NC contacts: 50,000 operations min.
Mechanical endurance
5,000,000 operations min.
5,000,000 operations min.
* The above values are for a switching frequency of 120 operations/min.
Characteristics
Item
G70V-SID16P(-1)(-C16)
(Input, DC coil)
G70V-SOC16P(-1)(-C4)
(output, DC coil)
Contact form
SPST-NO × 16
SPDT × 16
Contact material
Ag alloy + Au plating
Ag alloy
Contact resistance *1
150 mΩ max.
Must Operate time *2
20 ms max.
Release time *2
40 ms max.
Max.
switching

frequency
Mechanical limit
18,000 operations/h
At rated load
1,800 operations/h (under rated load)
Insulation resistance
100 MΩ min.
Dielectric strength
Between coil and contacts: 2,500 VAC for 1 min
Vibration resistance
100 m/s2
Shock resistance
100 m/s2, 3 times each in 6 directions along 3 axes
Noise immunity
Noise level: 1.5 kV; pulse width: 100 ns to 1 μs
Ambient operating
temperature
-40 to 55°C (with no icing or condensation)
Ambient operating humidity
35% to 85%
LED color
Power supply
Green
I/O
Yellow
Weight
Approx. 350 g
Approx. 370 g
Note: The above values are initial values.
*1. Measurement: 1 A at 5 VDC.

*2. Ambient temperature: 23°C.
Approved Standards
The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use.
UL standard certification (File No. E95399)
Type
Model
Ratings
Standard
number
Category
Listed/
Recognized
Contact ratings
I/O
Relay

Terminal
G70V-SID16P(-1)
24V DC
USL: UL 61010-1-12
CNL: UL 61010-2-201
NRAQ,
NRAQ7
Listed
24V DC
G70V-SID16P(-1)-C16
G70V-SOC16P(-1)
250V AC / 30V DC
Resistive 4A at 40°C
G70V-SOC16P(-1)-C4
I/O
Terminal

Sockets
G70V-ZID16P(-1)
Recognized
24V DC
G70V-ZID16P(-1)-C16
G70V-ZOM16P(-1)
250V AC / 30V DC
Resistive 4A at 40°C
G70V-ZOM16P(-1)-C4
G70V-ZOM16P(-1)-C4-D
Note:
1. USL refers to certification in the US, and CNL refers to certification in Canada.

2. cULus certification has been obtained in Canada. (CAN/CSA-C22.2 No. 61010-2-201)
G70V-SOC16P(-1): UL certification specifications
TÜV Rheinland certification (Certification No. R50327604)
Type
Model
Ratings
Standard
number
Operating
coil
Contact ratings
I/O
Relay

Terminal
G70V-SID16P(-1)
24V DC
EN 61810-1
24V DC
24V DC 0.05A L/R=0ms
G70V-SID16P(-1)-C16
G70V-SOC16P(-1)
single load: 250V AC 6A cos(phi)=1
16 loads: 250V AC 3A cos(phi)=1

16 loads: 30V DC 3A L/R=0ms

16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C)

16 loads: 30V DC 5A L/R=0ms (Ta=+25°C)
G70V-SOC16P(-1)-C4
250V AC / 30V DC
16 loads: 5A (Ta=+25°C)

16 loads: 3A (Ta=+55°C)

1 load: 6A

Resistive load

total max. 10A common line
I/O
Terminal

Sockets
G70V-ZID16P(-1)
24V DC
EN 61810-1
24V DC
24V DC 0.05A L/R=0ms
G70V-ZID16P(-1)-C16
G70V-ZOM16P(-1)
single load: 250V AC 6A cos(phi)=1
16 loads: 250V AC 3A cos(phi)=1

16 loads: 30V DC 3A L/R=0ms

16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C)

16 loads: 30V DC 5A L/R=0ms (Ta=+25°C)
G70V-ZOM16P(-1)-C4
250V AC / 30V DC
16 loads: 5A (Ta=+25°C)

16 loads: 3A (Ta=+55°C)

1 load: 6A

Resistive load

total max. 10A common line
G70V-ZOM16P(-1)-C4-D
CE Marking Compliance
Model
EMC Directive
Low Voltage Directive
Machinery Directive
G70V
Not applicable
Not applicable
Note:
1. The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components.

2. Details and other information on conformity levels are issued as part of the "EU Declaration of Conformity." Please contact your OMRON representative for more information.