Power Relays

G7Z

Multi-pole Power Relay for Contactor Current Range Capable of Carrying and Switching 40 A at 440 VAC

Ratings
Coil
Item
Rated
current

(mA)
Coil
resistance

(Ω)
Must operate
voltage
Must release
voltage
Maximum
voltage
Power
consumption

(W)
Rated voltage
Percentage of rated voltage
12 VDC
308
39
75% max.
10% min.
110%
Approx. 3.7
24 VDC
154
156
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with coil resistance of ±15%.
         2. Operating characteristics were measured at a coil temperature of 23°C.

         3. The maximum allowable voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C. There is, however, no continuous allowance.
Contacts
Relay, Relay with Auxiliary Contact Block
Model
G7Z-4A-[]Z-R, G7Z-3A1B-[]Z-R, G7Z-2A2B-[]Z-R
Load
Resistive load
Inductive load cosφ = 0.3
Resistive load L/R = 1 ms
Contact structure
Double break
Contact material
Ag alloy
Rated load
NO
40 A at 440 VAC
22 A at 440 VAC
5 A at 110 VDC
NC
25 A at 440 VAC
10 A at 440 VAC
5 A at 110 VDC
Rated carry current
NO
40 A *
NC
25 A
Maximum contact voltage
480 VAC
125 VDC
Maximum contact current
NO
40 A
22 A
5 A
NC
25 A
10 A
5 A
Maximum switching capacity
NO
17,600 VA
9,680 VA
550 W
NC
11,000 VA
4,400 VA
550 W
Failure rate P value (reference value)
2 A at 24 VDC
Note: The ratings for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.
* Set of Relay and Auxiliary Contact Block: 45 to 60°C; for the continuous carry current, reduce 40 A by 0.7 A/°C.

   (See Fig. 1.)
Auxiliary Contact Block
Item
G73Z-20Z-R, G73Z-11Z-R, G73Z-02Z-R
Resistive load
Inductive load cosφ = 0.3
Resistive load L/R = 1 ms
Contact structure
Single break
Contact material
Au clad + AgNi
Rated load
1 A at 440 VAC
0.5 A at 440 VAC
0.5 A at 110 VDC
Rated carry current
1A
Maximum contact voltage
480 VAC
125 VDC
Maximum contact current
1A
0.5 A
Maximum switching capacity
440 VA
220 VA
55 W
Failure rate P value
(reference value)
1 mA at 1 VDC
Characteristics
Classification
Relay with auxiliary contact block *5
Auxiliary contact block
Model
G7Z-4A-[]Z-R,
G7Z-3A1B-[]Z-R,

G7Z-2A2B-[]Z-R
G73Z-20Z-R,
G73Z-11Z-R,

G73Z-02Z-R
Contact resistance *1
400 mΩ max.
100 mΩ max.
Operating time *2
50 ms max.
Release time *2
50 ms max.
Maximum
operating

frequency
Mechanical
1,800 operations/h
Rated load
1,200 operations/h
Insulation resistance *3
1,000 MΩ min.
Dielectric
strength
Between coil and contacts
4,000 VAC, 50/60 Hz for 1 min
---
Between contacts of
different polarity
4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
2,000 VAC, 50/60 Hz for 1 min
Impulse
withstand

voltage
Between coil and contacts
10 kV, 1.2 × 50 μs
---
Between contacts of
different polarity
10 kV, 1.2 × 50 μs
Between contacts of the
same polarity
4.5 kV, 1.2 × 50 μs
3.0 kV, 1.2 × 50 μs
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction
NO: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
NC: 10 to 32 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction
Screw mounting: 700 m/s2, DIN Track mounting: 500 m/s2
Malfunction
NO: 100 m/s2
NC: 25 m/s
2
Durability
Mechanical
1,000,000 operations min. (at 1,800 operations/h, contact no load)
Electrical *4
AC resistive load: 80,000 operations
AC inductive load: 80,000 operations

DC resistive load: 100,000 operations

(at 1,200 operations/h, rated load)
Failure rate (P level)
(reference value) *6
2 A at 24 VDC
1 mA at 1 VDC
Ambient operating temperature
-25 to 60°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 330 g
Approx. 18 g
Note: The above values are initial values.
*1. The contact resistance for the Relay (G7Z) was measured with 1 A at 5 VDC using the voltage drop method. The contact resistance for the auxiliary contact block (G73Z) was measured with 0.1 A at 5 VDC using the voltage drop method.

*2. The operate time was measured with the rated voltage imposed with any contact bounce ignored at the ambient
temperature of 23.
*3. The insulation resistance was measured with a 1,000-VDC megohmmeter applied to the same places as those used for checking the dielectric strength.

*4. The electrical endurance was measured at an ambient temperature of 23
.
*5. The specifications for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.

*6. The failure rate is based on an operating frequency of 1,800 operations/h.
Approved Standards
UL Standard: (File No. E41643)
Classifi-cation
Con-tact
Mecha-nism

of

Auxi-liary

Con-tacts
Model
Num-ber
of

poles
Contact ratings
Number
of

test

opera-tions
Coil
ratings
Category
Listed/
Recog-nized
Relay
with

Auxiliary

Contact

Block
Single-break
models
G7Z-4A-20Z-R
G7Z-4A-11Z-R

G7Z-4A-02Z-R

G7Z-3A1B-20Z-R

G7Z-3A1B-11Z-R

G7Z-3A1B-02Z-R

G7Z-2A2B-20Z-R

G7Z-2A2B-11Z-R

G7Z-2A2B-02Z-R
4 poles
+

2 poles

(Relay

unit +

auxi-liary

con-tact)
NO
contact
Relay
40 A,
480 VAC,

60 Hz

(Resistive)
80,000
12, 24
VDC
NLDX2,
NLDX8
Recog-nized
5 A,
120 VDC (Resistive)
100,000
22 A,
480 VAC,

60 Hz

(General

Use)
100,000
Auxiliary
Contact
D300
(1-A

current

applied)
---
NC
contact
Relay
25 A,
480 VAC,

60 Hz

(Resistive)

5 A,

120 VDC

(Resistive)

10 A,

480 VAC,

60 Hz

(General Use)
100,000
Auxiliary
Contact
D300
(1-A

current

applied)
---
Relay
---
G7Z-4A
G7Z-3A1B

G7Z-2A2B
4 poles
(Relay)
NO
contact
(Relay)
40 A,
480 VAC,

60 Hz

(Resistive)
80,000
12, 24
VDC
NLDX2,
NLDX8
Recog-nized
5 A,
120 VDC

(Resistive)
100,000
22 A,
480 VAC,
60 Hz

(General Use)
100,000
NC
contact
25 A,
480 VAC,

60 Hz

(General Use)
100,000
5 A,
120 VDC

(Resistive)
10 A,
480 VAC,

60 Hz

(General

Use)
Auxiliary
Contact

Block
Single-break
models
G73Z-20Z-R
G73Z-11Z-R

G73Z-02Z-R
2 poles
(Auxi-liary

Con-tact

Block)
NO
contact
(Auxiliary
Contact)
D300
(1-A

current

applied)
---
---
NLDX2,
NLDX8
Recog-nized
NC
contact
D300
(1-A

current

applied)
CSA Standard: CSA Certification by cUL
EN Standard/TÜV Certification: EN 60947-4-1 (Certification No. R50079155)
Category
Contact
Mechanism

of Auxiliary

Contacts
Model
Number of
poles
Contact ratings
Relay with
Auxiliary

Contact

Block
Single-break
models
G7Z-4A-20Z-R
G7Z-4A-11Z-R

G7Z-4A-02Z-R

G7Z-3A1B-20Z-R

G7Z-3A1B-11Z-R

G7Z-3A1B-02Z-R

G7Z-2A2B-20Z-R

G7Z-2A2B-11Z-R

G7Z-2A2B-02Z-R
4 poles + 2 poles
(Relay unit +

auxiliary contact)
NO contact
Relay
AC-1: 40 A 440 V 50/60 Hz
AC-3: 16 A 440 V 50/60 Hz

DC-1: 5 A 110 V
Auxiliary
Contact
AC-15: 0.3 A 440 V 50/60 Hz
DC-13: 0.3 A 110 V
NC contact
Relay
AC-1: 25 A 440 V 50/60 Hz
DC-1: 5 A 110 V
Auxiliary
Contact
AC-15: 0.3 A 440 V 50/60 Hz
DC-13: 0.3 A 110 V
Relay
---
G7Z-4A
G7Z-3A1B

G7Z-2A2B
4 poles
(Relay)
NO contact
(Relay)
AC-1: 40 A 440 V 50/60 Hz
AC-3: 16 A 440 V 50/60 Hz

DC-1: 5 A 110 V
NC contact
AC-1: 25 A 440 V 50/60 Hz
DC-1: 5 A 110 V
Auxiliary
Contact

Block
Single-break
models
G73Z-20Z-R
G73Z-11Z-R

G73Z-02Z-R
2 poles
(Auxiliary Contact

Block)
NO contact
(Auxiliary
Contact)
AC-15: 0.3 A 440 V 50/60 Hz
DC-13: 0.3 A 110 V
NC contact
AC-15: 0.3 A 440 V 50/60 Hz
DC-13: 0.3 A 110 V
CCC Certification
Classification
Contact Mechanism
of Auxiliary Contacts
Model
Standard No.
Certification No.
Relay with Auxiliary
Contact Block
Single-break models
G7Z-4A-20Z-R
G7Z-4A-11Z-R

G7Z-4A-02Z-R
G7Z-3A1B-20Z-R

G7Z-3A1B-11Z-R

G7Z-3A1B-02Z-R

G7Z-2A2B-20Z-R

G7Z-2A2B-11Z-R

G7Z-2A2B-02Z-R
GB/T 14048.4
2009010304361493
Relay
---
G7Z-4A
G7Z-3A1B

G7Z-2A2B
GB/T 14048.4