Liquid Analysis
Endress+Hauser Liquid Analysis is one of the world’s leading providers of measuring instruments and complete systems for liquid analysis.
Products List
4-channel transmitter Liquiline CM444
Expandable multiparameter field device for all industries
Predecessor: CCM360, Sludge level CUM750
Input:1 to 4x Memosens digital input, 2x 0/4 to 20mA Input optional, 2 to 4x Digital input optional
Output / communication: 2 to 8x 0/4 to 20 mA current outputs, alarmrelay, 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Ingress protection: IP66 / IP 67
Digital pH sensor Memosens CPS11E
Memosens 2.0 pH electrode for standard applications in process and water & wastewater industries
Predecessor: Orbisint CPS11D
Measurement range: Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
Application F
• pH: 0 to 10Process temperature: Application A: –15 to 80 °C (5 to 176 °F), Application B: 0 to 135 °C (32 to 275 °F), Application F: 0 to 70 °C (32 to 158 °F)
Process pressure: Applications A and B: 0.8 to 17 bar (11.6 to 246.5 psi) absolute, Application F:0.8 to 7 bar (11.6 to 101.5 psi) absolute
Ammonium analyzer Liquiline System CA80AM
Colorimetric system for online monitoring of water and wastewater treatment
Predecessor: Stamolys CA71AM
Measurement range: 0.05 to 20 mg/l NH4-N
0.5 to 50 mg/l NH4-N
1 to 100 mg/l NH4-N
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l NH4-NProcess temperature: 4 to 40 °C (39 to 104 °F)
Process pressure: Unpressurized
Measuring method: Comply with standard colorimetric measuring principle – indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87
COD analyzer Liquiline System CA80COD
Analyzer for chemical oxygen demand in environmental monitoring, industrial and municipal wastewater
Predecessor: Stamolys CA71COD
Measurement range; 0 to 500 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method + dilution module (1:4)Process temperature: 4 to 40 °C (39 to 104 °F)
Process pressure: Atmospheric
Orthophosphate analyzer Liquiline System CA80PH
Colorimetric system for wastewater monitoring and optimization of process control
Predecessor: Stamolys CA71PH
Measurement range: 0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)Process temperature: 4 to 40 °C (39.2 to 104 °F)
Process pressure: At atmospheric pressure, < 0.2 bar
Digital chlorine dioxide sensor Memosens CCS50D
Memosens sensor for water, process water and utilities in all industries
Measurement range: Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2Process temperature: 0 to 55 °C , non-freezing(32 to 130 °F)
Process pressure: Max. 2 bar abs (Max. 29 psi abs)
Digital free chlorine sensor Memosens CCS51D
Memosens sensor for drinking water, pool and process water as well as utilities in all industries
Predecessor: Chloromax CCS142D
Measurement range: Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOClProcess temperature: 0 to 55 °C (32 to 130 °F), non-freezing
Process pressure: Max. 1 bar (max. 14.5 psi)
Measuring method: Closed, membrane covered measuring cell. Reduction of free chlorine at the cathode
Cleaning and calibration system Liquiline Control CDC90
Fully automatic system for pH and ORP measuring points in all industries
Predecessor: Topcal S CPC310
PAH sensor Memosens CFS51
Memosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)
Measurement range: 0.000 to 5000 PAHphe
Process temperature: -5 to 55 °C (20 to 130 °F)
Process pressure: 10 bar abs. (just the sensor), 6 bar abs. (combination sensor and assembly)
Process spectrometer Memosens Wave CKI50
Memosens Wave spectrometer for color measurement in the Food & Beverage, Chemical and Life Sciences industries
Measurement range: L: 0 to 100
a: -150 to 100
b: -100 to 150Process temperature: -20 to 60 °C (-4 to 140 °F)
60 to 140 °C (140 to 284 °F) with water coolingProcess pressure: 0.5 to 10 bar (7.3 to 145 psi) (absolute
Digital 4-electrode conductivity sensor Memosens CLS82D
Memosens conductive conductivity sensor for hygienic applications in Life Sciences, Pharma and Food
Predecessor: Condumax CLS30
Successor: Memosens CLS82E
- Measurement range: 1 µS/cm to 500 mS/cm
- Process temperature: -5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min (Max. 284 °F at 87 psi for max. 45 min)
Process pressure: 17 bar abs at 20 °C (247 psi at 68 °F), 9 bar abs at 120 °C (131 psi at 248 °F)
Digital oxygen sensor Memosens COS81D
Memosens optical oxygen sensor for hygienic applications in Life Sciences, Pharma and Food
Successor: Memosens COS81E
- Measurement range:0.004 to 30 mg/l
0.05 to 330 %SAT
0.1 to 700 hPa
- Process temperature: 0 to 140 °C (32 to 284 °F)
- Process pressure: 0.02 to 13 bar abs (0 to 190 psi)
Digital pH sensor Memosens CPF81E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Predecessor: Orbipac CPF81D
Measurement range: pH 0 to 14
Process temperature: Version LH: 0 to 110 °C (32 to 230 °F), Version NN: 0 to 80 °C (32 to 170 °F)
Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi at 176 °F)
Digital ORP sensor Memosens CPF82E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Predecessor: Orbipac CPF82D
Measurement range: -1500mV to +1500mV
Process temperature: 0 to 80 °C (32 to 170 °F)
Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi abs at 176 °F)
Digital pH sensor Memosens CPS171D
Memosens glass electrode for bioreactors in the biotech industry and for the food industry
Successor: Memosens CPS61E
Measurement range: pH 0 to 14
Process temperature: 0 to 135 °C (32 to 275 °F)
Process pressure: 1 to 7 bar abs (14.5 to 101.5 psi)
Digital pH sensor Memosens CPS61E
Memosens 2.0 glass sensor for the food & beverage industry and for bioreactors in biotech industry
Predecessor: Ceragel CPS71D, Memosens CPS171D
Measurement range: pH: 0 to 14
Process temperature: Application N: 0 to 100 °C (32 to 212 °F) Up to 140 °C (284 °F) for sterilization
Process pressure: 0.8 to 7 bar (11.6 to 101.5 psi) absolute
Digital ORP sensor Memosens CPS62E
Memosens 2.0 ORP electrode for the chemical and life sciences industries
Measurement range: –1 500 to 1 500 mV
Process temperature: 0 to 100 °C (32 to 212 °F) 0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)
Process pressure: 0.8 to 7 bar (11.6 to 101.5 psi) absolute
Combined pH/ORP sensor Memosens CPS76E
Memosens 2.0 pH electrode for chemical processes and poisoning media
Predecessor: Ceragel CPS71D
- Measurement range: ORP: –1 500 to 1 500 mV
Application B
• pH: 0 to 14
Application H
• pH: 0 to 12
Process temperature: Application B and H: 0 to 140 ° C (32 to 284 ° F)
Version TB: 0 to 140 ° C (32 to 284 ° F)
Version TU, TP (pressurized reference): 0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
maximum 100 ° C (212 ° F) in continuous operation due to increasing pressure drop at T> 100 ° C (212 ° F)Process pressure: Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute
Digital pH sensor Memosens CPS71E
Memosens 2.0 combined electrode for chemical processes and poisoning media
Predecessor: Memosens CPS76D
Measurement range: Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12Process temperature: 1 to 140 °C (32 to 284 °F)
Process pressure: 0,8 to 14 bar (11,6 to 203 psi) (absolute)
Digital combined pH/ORP sensor Memosens CPS96E
Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production
Predecessor: Memosens CPS96D
Measurement range: ORP: –1 500 to 1 500 mV
pH: 0 to 14Process temperature: 0 to 110 °C (32 to 230 °F)
Process pressure: 0.8 to 14 bar (11.6 to 203 psi) absolute
Turbidity sensor Turbimax CUS52D
Hygienic Memosens sensor for turbidity measurement in drinking water, process water and utilities
Predecessor: Turbimax CUE21, Turbimax CUS31, Turbimax CUS65
Measurement range: 0.000 to 4000 FNU
Process temperature: Stainless steel version: -20 to 85 °C (0 to 185 °F)
Plastic version: -20 to 60°C (-4 to 140 °F)Process pressure: Stainles steel version: 0.5 to 10 bar abs
(7.3 to 145 psi abs)
Plastic version: 0.5 to 6 bar abs
(7.3 to 87 psi abs)
Liquid Analysis Physical Medium Properties Liquitrend QMW43
Compact device for continuous buildup thickness and conductivity measurement
Measurement range: Conductivity: 0 µS/ cm…100 mS/ cm
Build-up thickness: 0 mm…10 mmProcess temperature: -20°C…+100°C (-4°F…+212°F) +150°C (+302°F) for 1h
Process pressure: Vacuum…25 bar, (Vacuum…362.5 psi)
Measuring method: Capacitive- conductive
Digital nitrate or SAC sensor Viomax CAS51D
Memosens sensor for optical measurement of nitrate, SAC, CODeq, TOCeq, BODeq or DOCeq
Predecessor: Stamosens CSS70, Stamosens CNS70
Measurement range: 0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N
0.04 to 80 mg/l / 0.4 to 200 mg/l NO3
0 to 50 1/m / 0 to 250 1/m / 0 to 1000 1/m SAC
0 to 75 mg/l / 0 to 375 mg/l / 0 to 1500 mg/l COD/BOD (254nm)
0 to 30 mg/l / 0 to 150 mg/l / 0 to 600 mg/l TOC/DOC (254nm)Process temperature: 5 to 50°C (41 to 120 °F)
Digital total chlorine sensor Memosens CCS120D
Memosens disinfection sensor for wastewater and process water
Measurement range: 0.1 to 10 mg/l total chlorine
Process temperature: 5 to 45 °C (41 to 113 °F)
Process pressure: 1 to 4 bar (14.5 to 58 psi)
Measuring method: Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent
Digital free bromine sensor Memosens CCS55D
Memosens sensor for seawater and process water
Measurement range: Trace: 0 … 5 mg/l HOBr
Standard: 0 … 20 mg/l HOBr
High: 0 … 200 mg/l HOBrProcess temperature: +0…55 °C (32 … 130°F), non-freezing
Process pressure: Max. 1 bar (max. 14.5 psi)
Compact conductivity device Smartec CLD18
Toroidal conductivity measuring system for hygienic applications
Predecessor: CLD133, CLD633
Measurement range: 200 µS/cm to 1000 mS/cm, Cell constant k: 11.0 1/cm
Process temperature: -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min (Max. 266 °F at 87 psi up to 60 min)Process pressure: 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
Digital conductivity sensor Memosens CLS15E
Memosens 2.0 contacting conductivity sensor for standard applications in pure and ultrapure water
Predecessor: Condumax CLS15D
Measurement range: k=0,01: 0.04 to 20 µS/cm, k=0,1: 0.10 to 200 µS/cm
Process temperature: Threaded with fixed cable: -20 to 100 °C (-4 to 212 °F)
Threaded with plug-in head: -20 to 120 °C (-4 to 248 °F)
Sterilization: max. 140 °C (284 °F) for 30 minutesProcess pressure: 13 bar at 20 °C (188 psi at 68 °F) absolute
1 bar at 120 °C (14 psi at 248 °F) absolute
Digital conductivity sensor Condumax CLS16D
Memosens conductive conductivity sensor for hygienic applications in pure and ultrapure water
Successor: Memosens CLS16E
Measurement range: k=0,1: 0,04 to 500 µS/cm
Process temperature: -5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar (Max. 302 °F at 73 psi)Process pressure: 13 bar at 20 °C (188 psi at 68 °F), 9 bar at 120 °C (130 psi at 248 °F)
Digital conductivity sensor Memosens CLS16E
Memosens 2.0 contacting conductivity sensor for hygienic applications in life sciences and food
Predecessor: Condumax CLS16D
Measurement range: k=0,1: 0,04 to 500 µS/cm
Process temperature: -5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar (Max. 302 °F at 73 psi)Process pressure: 13 bar at 20 °C (188 psi at 68 °F), 9 bar at 120 °C (130 psi at 248 °F)
Digital conductivity sensor Memosens CLS21E
Memosens 2.0 contacting conductivity sensor for surface and drinking water monitoring
Predecessor: Condumax CLS21D
Measurement range: k=1: 10 µS/cm to 20 mS/cm
Process temperature: -20 to 135 °C at 3.5 bar abs (-4 to 275 °F at 50 psi)
Process pressure: 17 bar abs at 20 °C (246 psi at 68 °F)