Product Category

Liquid Analysis

Products List

Assembly for process photometers OUA260

Flow assembly for a variety of optical inline measurements

  • Process temperature: 0 to 130 °C (32 to 194 °F)
  • Process pressure: up to 20 bar (300 psi) depending on material, mean diameter and process connection

 

Glass-free absorption sensor OUSAF11

NIR/VIS absorption sensor for phase detection and suspended solids

  • Measurement range: 0 to 3 AU, 0 to 6 OD (depending on optical path length)
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 10 bar abs at 20 °C, (Max. 150 psi at 68 °F)

 

Suspended solids and color sensor OUSAF12

NIR/VIS absorption sensor for suspended solids and phase detection

  • Measurement range: 0 to 2.5 AU, 0 to 50 OD (depending on optical pathlength)
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 100 bar abs (1450 psi) (depending on flow through assembly)

 

Color sensor OUSAF22

NIR/VIS absorption sensor for color and purity monitoring

  • Measurement range: 0 to 2.5 AU
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 100 bar (1450 psi) (depending on flow through assembly)

 

UV absorption sensor OUSAF44

Sensor for inline product quantification

  • Measurement range: 0 to 2.5 AU, 0 to 50 OD (depending on optical pathlength)
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly

 

UV absorption sensor OUSAF46

Sensor for inline product quantification at two specific UV wavelengths

  • Measurement range: 0 to 2.5 AU, 0 to 50 OD (depending on optical pathlength)
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly

 

Cell growth and biomass sensor OUSBT66

Hygienic NIR absorption measurement in fermentation and crystallization applications

  • Measurement range: 0 to 4 AU, 0 to 8 OD (depending on optical path length)
  • Process temperature: 0 to 90 °C (32 to 194 °F), Max. 135 °C for max. 2 hours
  • Process pressure: Max. 10 bar abs at 90 °C, (Max. 150 psi at 194 °F)

 

Inline turbidity sensor OUSTF10

Turbidity and suspended solids measurement by light scattering and absorbance

  • Measurement range: 0 to 200 FTU, 0 to 200 ppm DE
  • Process temperature: 0 to 90 °C (32 to 194 °F) continuous, Max. 130 °C (266 °F) for 2 hours
  • Process pressure: Max. 100 bar (1450 psi), (depending on flow through assembly)

 

pH measuring point including sensor with polymer housing

Ready to use pH measuring point with digital Memosens 2.0 sensor with polymer housing to manage your process in the harsh environment of wastewater

Digital Memosens 2.0 technology Simple operation thanks to true plug and play system and helpful overview of the last eight calibrations and adjustments.

Ready for predictive maintenance State of the art technologies as the pH load matrix and Heartbeat Technology allow full predictive maintenance. A PLC is not needed with the Liquiline transmitter, providing maximum flexibility for operators.

Flexibile adaptation The modular fitting system allows almost any type of fixing, in open basins or channels. A modification or expansion of the assembly is possible at any time.

Buffer solution from accredited production NIST traceable buffer solutions offer precision in measurement and adjustments, ensuring best performance.

Complete ultrasonic bed level measuring point

Proven solution for standard applications in mining, minerals and metals

Smooth and robust measurements Thanks to the integrated wiper, the ultrasonic Turbimax CUS71D bed level sensor delivers reliable, continuous measurements in thickener applications.

Simple commissioning Predefined calibration models and the calibration- and sensor-related data saved in the sensor make commissioning fast and easy.

Comfortable operation The versatile Liquiline CM442 transmitter offers a user-friendly operating menu and advanced diagnostic functionalities with Hearbeat Technology. The weather protection cover CYY101 ensures easy readability of the Liquiline CM442 display at the measuring point.

Optimal adaptation to your process requirements The Flexdip CYH112 immersion assembly offers flexible adaptation options perfectly fitting to the thickener design and the measuring task.

Complete measuring loop for SAC in the wastewater outlet

Save time with this pre-configured package for optical SAC measurement that ensures reliable process monitoring

Continuous measurement directly in the drain Thanks to an optical measurement of organic pollution in the wastewater treatment plant outlet with the Viomax CAS51D SAC sensor, you always have the critical values in view. The sensor ensures on-line measurement of SAC254, COD, BOD, TOC or DOC equivalents directly in the outlet.

Fast response time and efficient process control The Viomax CAS51D SAC sensor provides reliable real-time process information thanks to its extremely fast response time and measured value processing in the sensor.

Save time and costs and protect the environment The great advantage of measuring with the optical sensor is that no chemicals or consumables are required; sample preparation is also not necessary. The standardized Memosens technology also enables very simple, time-saving operation and maintenance. The sensor and process-specific data stored in the sensor increase process reliability. An optionally available automatic compressed air cleaning system additionally ensures long maintenance intervals.

Ready for automation The Liquiline CM442 transmitter offers numerous possibilities for automatic measuring operation. For example, cleaning or dosing is possible without a PLC and thanks to the logbook function of the Liquiline transmitter, no separate register is necessary.

Modular holder system for open basins and channels Flexdip CYH112 offers high flexibility for measurements directly where they are needed. It allows almost any sensor mounting such as floor mounting, chain type installation, fixed or free swinging mounting. As the system installs quickly it saves time and costs and it can be expanded or modified at any time.

pH measuring point in flotation processes

Reliable pH measurement for optimal beneficiation processes in Mining, Minerals and Metals industry

Benefits at a glance

  • Fast response time for precise process control
  • Minimized risk of blocking in contaminated solutions thanks to the open junction of Memosens CPS91E
  • Built-in ion trap ensures longer lifetime
  • Advanced diagnostic options thanks to Heartbeat Technology and intuitive operation
  • Modular immersion assembly which can be upgraded with a cleaning nozzle to automate cleaning in the process

pH measurement in abrasive media and cyanide leaching

Complete measuring point for reliable pH measurement in Mining, Minerals and Metals industry

Benefits at a glance

  • Memosens CPF81E pH sensor with flat membrane suitable for abrasive media
  • pH sensor with patented electrolyte bridge for improved protection against electrode poisoning
  • Easy sensor installation thanks to threaded connections on both ends
  • Robust polymer housing
  • Versatile Liquiline CM442 transmitter offers advanced diagnostic functionalities with Heartbeat Technology
  • Immersion assembly Flexdip CYA112 can be optionally upgraded with a cleaning nozzle to automate cleaning operation

pH glass sensor measuring point for wastewater applications

Pre-configured pH measuring station with Memosens 2.0 glass sensor for time-saving process monitoring and management

Digital Memosens 2.0 technology True plug and play system for easy handling and overview of the last eight calibrations and adjustments.

Ready for predictive maintenance Thanks to the pH load matrix and Heartbeat Technology the measuring point can provide full predictive maintenance. With the transmitter, the measuring point does not need a PLC for remote control, offering maximum flexibility.

Flexibility The modular fitting system allows almost any type of fixing, in open basins or channels. A modification or expansion of the assembly is possible at any time.

Certified buffer solutions NIST traceable buffer solutions ensure best performance and precision of the measurement and adjustment.

Automatic cleaning system Liquiline Control CDC30 (230 VAC)

Basic solution for the realization of a fully automatic cleaning system for retractable assemblies

High process reliability and low maintenance Minimal downtime with Liquiline Control CDC30. With the system, you no longer have to worry about almost anything during measurements, as the system takes care of sensor cleaning completely. You save time and have less work, especially if the sensors in your application need to be cleaned frequently.

Pre-configured and preassembled basic solution Simple and fast commissioning: Everything ready to go, all you have to do is quickly mount the panel on the wall and/or in the control cabinet. And since everything is already wired, the connection to your measuring point ist also done in no time at all.

Adjustable, pre-configured cleaning programs Parameterizable rinsing and/or cleaning programs, either time-controlled or cycle-controlled – just as it suits your application.

Rinsing and cleaning cycles without additional dosing pump The Chemoclean CYR10B cleaning injector for dosing cleaning concentrate is a spray cleaning system for pH/ORP sensors as well as for oxygen and turbidity sensors.

Automatic cleaning system Liquiline Control CDC30 (24 VDC)

Basic solution for the realization of a fully automatic cleaning system for retractable assemblies

High process reliability and low maintenance Minimal downtime with Liquiline Control CDC30. With the system, you no longer have to worry about almost anything during measurements, as the system takes care of sensor cleaning completely. You save time and have less work, especially if the sensors in your application need to be cleaned frequently.

Pre-configured and preassembled basic solution Simple and fast commissioning: Everything ready to go, all you have to do is quickly mount the panel on the wall and/or in the control cabinet. And since everything is already wired, the connection to your measuring point ist also done in no time at all.

Adjustable, pre-configured cleaning programs Parameterizable rinsing and/or cleaning programs, either time-controlled or cycle-controlled – just as it suits your application.

Rinsing and cleaning cycles without additional dosing pump The Chemoclean CYR10B cleaning injector for dosing cleaning concentrate is a spray cleaning system for pH/ORP sensors as well as for oxygen and turbidity sensors.

ERP integration software IMS Middleware SXS70

Integration of data from inventory management software packages into ERP

Dissolved oxygen measuring point for wastewater

Preconfigured dissolved oxygen measuring loop for reliable and accurate process monitoring and control in wastewater applications

Digital Memosens Technology Thanks to Memosens digital technology you can benefit from maximum process and data integrity and simple lab calibration.

Ready for automation This measuring point can be used as a stand-alone system to control your aeration or can be integrated in your PLC with its extended communication protocols.

Flexibility The modular fitting system allows various types of fixing, in open basins or channels. It gives easy access to the sensor for commissioning and maintenance.

Multiparameter drinking water panel

Ready-to-use panel bundle for measurement of the most important drinking water parameters pH, conductivity, turbidity and free chlorine

Easy planning: The bundle comprises all necessary components for comprehensive monitoring your drinking water. You can be sure to select the right measuring technology for your plant.

Fast commissioning: The Memosens sensors for pH, conductivity, turbidity and free chlorine are factory-calibrated. Simply connect them to the Liquiline transmitter via true plug and play and start measuring.

Reliable measurement at low water consumption: The design of the integrated assembly minimizes the amount of water consumed while the intergrated flow monitoring ensures that your measurement is always operational.

Perfectly suited to all disinfection steps: With the Memosens CCS51D free chlorine sensor included, the bundle is perfectly suited to all water treatment steps that involve disinfection such as pretreatment, conditioning and disinfection or distribution.

Free bromine process water panel

Ready-to-use bundle for disinfection monitoring in seawater and process water

Fast commissioning: The panel comes fully wired and piped. You only need to mount it, connect it to power and water, and you are ready for operation.

Memosens for simple and safe operation: The Memosens sensors for free bromine and pH are pre-calibrated. Just plug them in and benefit from reliable measurement, not affected by moisture or corrosion.

Consistent medium flow: The Flowfit CYA27 assembly with integrated flow monitoring makes sure that your measurement is always operational. The status indication light indicates the NAMUR NE107 status, allowing for direct reaction to errors.

Perfect adaption to process requirements: Thanks to the modular design of the assembly, the bundle can easily be extended to more parameters such as ORP, conductivity or dissolved oxygen. This offers you the necessary flexibility to adapt the panel to your process requirements at any time.

Multiparameter drinking water panel with oxygen measurement

Turnkey panel for measuring the main drinking water parameters: dissolved oxygen, turbidity, pH and conductivity

Everything from a single source: Easy ordering of all components for drinking water monitoring, fully assembled and everything from a single provider.

Always ready for the measurements: Thanks to factory-calibrated sensors, the drinking water panel is ready for immediate use. An assembly with integrated flow monitoring ensures an interruption-free measuring operation.

Maximum flexibility: The modular design of the solution enables perfect adaptation to process requirements and offers maximum flexibility for future expansions of a measuring point.

Easy installation and commissioning: With the Endress+Hauser water quality monitoring panel, installing and commissioning measuring points is simple: just screw the ready-made solution to the wall, connect it to power and water, and you’re ready to go.