Radar sensors
NivoRadar® - NR 3100









Application area
The free-radiating radar sensor NivoRadar® 3100 is mainly used in storage silos for level measurement of bulk solids. The 4 ° narrow beam and a measuring range of up to 100 meters make the sensor a compatible solution for a wide range of applications in the field of non-contact measuring technology. The easy to operate display, the Quick Start Wizard and displayed diagnostic data allow simple installation on site.
Technical Data
Measurement principle | Radar (non-contact) |
---|---|
Measuring task | Continuous level measurement |
Version |
|
Medium | Solids |
Mounting position |
|
Ambient temperature | -40°C … +80°C (-40°F … +176°F) |
Process temperature | -40°C … +200°C (-40°F … +392°F) |
Process pressure | -1 bar … +3 bar (-14.5 psi … +43 psi) |
Minimum sensitivity | DK ≥ 1.6 |
Housing type | standard |
Housing material | Stainless steel 1.4404 (316L) |
Housing protection rating | IP68, NEMA Type 4X, NEMA Type 6 |
Threaded connection | — |
Flange connection |
|
Hygienic fittings | — |
Wetted materials |
|
Mechanical load | — |
Accuracy | ± 5 mm (± 0.2″) |
Min. immersion length | 0 mm (0″) |
Max. immersion length | 0 mm (0″) |
Power supply | 16,5…30V DC |
Signal output | 4…20 mA/ HART (2-wire) |
Approvals |
|
Explosion protection |
|
Hygienic / Pharma |
|
Ship approval | — |
Overfill protection | — |
SIL qualification | — |
Further approvals | — |
User Interface |
|
Optical indicator | Display |
Adjustment possibility |
|