Pressure measurement
Endress+Hauser Pressure measurement is one of the world’s leading providers of measuring instruments and complete systems for Pressure measurement.
Products List

Deltabar PMD55B - differential pressure transmitter
Smart transmitter with metal membrane for differential pressure monitoring in liquids and gases
- Accuracy: Standard:
up to 0.075 %
Platinum:
up to 0.055 % - Process temperature: -40°C…+110°C (-40°F…+230°F)
- Pressure measuring range: 30 mbar…. 40 bar (0.45 psi… 600 psi)
- Main wetted parts: 316L, AlloyC
- Material process membrane: 316L, AlloyC
- Measuring cell: 30 mbar…40 bar, (0.45 psi…600 psi)

Deltabar PMD75B - differential pressure transmitter
Smart pressure transmitter which detects process anomalies like plugged impulse lines
- Accuracy: Standard:
up to 0.05 %
Platinum:
up to 0.035 % - Process temperature: -40°C…+110°C
(-40°F…+230°F) - Pressure measuring range: 10 mbar…250 bar
(0.15 psi…3750 psi) - Main wetted parts: 316L, AlloyC,
Tantal, Monel,
Gold - Material process membrane: 316L, AlloyC,
Tantal,
Monel,
Gold - Measuring cell: 10 mbar…250 bar, (0.15 psi…3750 psi)

Cerabar PMP51B - pressure transmitter
Smart pressure transmitter with metal membrane for highly accurate measurement of liquids and gases
- Accuracy: Standard:
up to 0.075 %
Platinum
up to 0.055 % - Process temperature: Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C…+400°C
(-40°F…+752°F) - Pressure measuring range: 400 mbar… 400 bar
(6psi…6,000psi) - Main wetted parts: 316L, AlloyC,
Tantal, Monel,
PTFE - Material process membrane: 316L, AlloyC,
Tantal, Monel,
PTFE
Measuring cell: 400 mbar…400 bar, (6psi…6,000psi)

Cerabar PMP71B - pressure transmitter
Smart pressure transmitter – its health can be verified without process interruption
- Accuracy: Standard:up to 0.05 %
Platinum: up to 0.025 % - Process temperature: Standard:-40°C…+125°C, (-40°F…+257°F)
Diaphragm seal: -40°C…+400°C, (-40°F…+752°F) - Pressure measuring range: 400 mbar…700 bar, (1.5 psi…10,500 psi)
- Main wetted parts: 316L, AlloyC, Tantal, Monel, PTFE, Gold
- Material process membrane: 316L, AlloyC, Tantal, Monel, PTFE, Gold
Measuring cell: 400 mbar…700 bar, (6 psi…10,500 psi)

Electronic differential pressure Deltabar FMD71
Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter
- Accuracy: 0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor - Process temperature: –25…+150°C
(–13…+302°F) - Pressure measuring range: 100mbar…40bar
(1.5psi…600psi) - Process pressure / max. overpressure limit: 60 bar (900 psi)
- Material process membrane: Ceramic, 316L, AlloyC
- Measuring cell: 100 mbar…40 bar, (1.5 psi…600 psi)

Electronic differential pressure Deltabar FMD72
Electronic differential pressure system utilizing two metal sensor modules and one transmitter
- Accuracy: 0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor - Process temperature: –40…+125°C
(–40 … +257°F) - Pressure measuring range: 400 mbar…10 bar
(6 psi…150 psi) - Process pressure / max. overpressure limit: 160 bar (2400 psi)
- Main wetted parts: 316L, Alloy C
- Material process membrane: 316L, AlloyC,
- Measuring cell: 400 mbar…10 bar, (6 psi…150psi)

Absolute and gauge pressure Cerabar PMC21
Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids
Predecessor: Cerabar T PMC131
- Accuracy: 0.3 %
- Process temperature: -25 °C…+100 °C
(-13 °F….+185 °F) - Pressure measuring range: +100 mbar…+40 bar
(+1.5 psi…+600 psi) - Measuring cell: +100 mbar…+40 bar, (+1.5 psi…+600 psi)

Absolute and gauge pressure Cerabar PMC51
Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids
Predecessor: Cerabar M PMC41, Cerabar M PMC45
- Accuracy: Standard 0.1%, Platinum 0.075%
- Process temperature: -20°C…130°C, (-4°F…266°F)
- Pressure measuring range: 100 mbar…40 bar, (1.5psi…600psi)
- Process pressure / max. overpressure limit: 60 bar (900 psi)
- Main wetted parts: Ceraphire
Sealing
Alloy C276
316L - Max. measurement distance: 400 m (1312 ft) H2O
- Material process membrane: Ceramic
- Measuring cell: 100 mbar…40 bar, (1.5 psi…600 psi), relative/ absolute

Absolute and gauge pressure Cerabar PMC71
Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids
Predecessor: Cerabar S PMC731
- Accuracy: Standard: 0.05%, Platinum: up to 0.025%
- Process temperature: -40°C…150°C, (-40°F…302°F)
- Pressure measuring range: 100mbar…40bar, (1.5psi…600psi)
- Process pressure / max. overpressure limit: 60bar (900psi)
- Main wetted parts: Ceraphire ceramic
Alloy C
316L
Monel
PVDF - Max. measurement distance: 400m (1312ft) H2O
- Material process membrane: Ceramic
- Measuring cell: 100 mbar…40 bar, (1.5 psi…600 psi), relative/ absolute

Differential pressure Deltabar PMD55
Differential pressure transmitter with metal sensor for measurement of pressure differences
- Accuracy: 0,1%, “PLATINUM” 0,075%
- Max. measurement error: 0,1%
“PLATINUM” 0,075% - Process temperature: -40 °C…85 °C
(-40 °F…185 °F) - Medium temperature range: Temperature gradient from pressure piping
- Pressure measuring range: 10mbar…40bar
(0.15…580psi) - Process pressure / max. overpressure limit: 160 bar
- Main wetted parts: 316L
- Max. process pressure: 10 mbar…40 bar
(0.15…580 psi) - Material process membrane: 316L, AlloyC,
- Measuring cell: 10 mbar…40 bar, (0.15…580 psi)

Differential pressure Deltabar PMD75
Differential pressure transmitter with metal sensor for measurement of pressure differences
Predecessor: Deltabar S PMD70, Deltabar S PMD235
- Accuracy: Standard: 0.05%
Platinum: up to 0.035% - Max. measurement error: 0,075%
“PLATINUM” 0,05% - Process temperature: -40 °C…85 °C
(-40 °F…185 °F) - Medium temperature range: Temperature gradient from pressure piping
- Pressure measuring range: 10 mbar…250 bar (0.15 psi…3750 psi)
- Process pressure / max. overpressure limit: 420 bar (6300 psi)
- Main wetted parts: Alloy C276
316L
Monel
Tantalum - Max. measurement distance: 400 m (1.312 ft) H2O
- Max. process pressure: max. 420 bar (max. 6091 psi)
- Material process membrane: 316L, AlloyC, Tantal, Gold-Rhodium
- Measuring cell: 10 mbar…250 bar, (0.15 psi…3750 psi)

Absolute and gauge pressure Cerabar PMP21
Cost-effective pressure transducer with metal sensor for measurement in gases or liquids
Predecessor: Cerabar T PMP131
- Accuracy: 0.3%
- Process temperature: -40…+100°C, (-40…+212°F)
- Pressure measuring range: 400 mbar…+400 bar, (6…+6000psi)
- Measuring cell: +400 mbar…+400 bar, (+6 psi…+6000 psi)

Absolute and gauge pressure Cerabar PMP23
Cost-effective pressure transducer with fully welded design for the food & beverage industry
Predecessor: Cerabar T PMP135
- Accuracy: 0.3%
- Process temperature: -10…+100°C (+14…+212°F)
135°C for 1h (275°F for 1h) - Pressure measuring range: 400 mbar…+40 bar (6…+600psi)
- Measuring cell: +400 mbar…+40 bar (+6 psi…+600 psi)

Absolute and gauge pressure Cerabar PMP51
Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids
Predecessor: Cerabar M PMP41, Cerabar M PMP45
- Accuracy: Standard 0.1%
Platinum 0.075% - Process temperature: -40°C…130°C (-40°F…266°F)
- Pressure measuring range: 1 bar…400 bar (15 psi…6000 psi)
- Process pressure / max. overpressure limit: 600 bar (9000 psi)
- Main wetted parts: 316L
- Max. measurement distance: 4000 m (13.123 ft) H2O
- Material process membrane: 316L, AlloyC, Rhodium>Gold
- Measuring cell: 400mbar…400bar (15psi…6000psi), relative/ absolute

Absolute and gauge pressure Cerabar PMP55
Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids
Predecessor: Cerabar M PMP46, Cerabar M PMP48, Cerabar M PMP48
- Accuracy: Standard 0.15%
Platinum 0.075% - Process temperature: -70°C…400°C
(-94°F…752°F) - Pressure measuring range: 1 bar…400 bar
(15 psi…6000 psi) - Process pressure / max. overpressure limit: 600 bar (9000 psi)
- Main wetted parts: 316L
AlloyC
Montel
Tantal
Rhodium - Max. measurement distance: 4000m (13.123ft) H2O
- Material process membrane: 316L, AlloyC, Tantal, PTFE, Rhodium>Gold
- Measuring cell: 400 mbar…400 bar (15 psi…6000 psi), relative/ absolute

Absolute and gauge pressure Cerabar PMP71
Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids
Predecessor: Cerabar S PMP731
- Accuracy: Standard: 0.05%
Platinum: up to 0.025% - Process temperature: -40°C…125°C (-40°F…257°F)
- Pressure measuring range: 100mbar…700bar
(1.5psi…10.500psi) - Main wetted parts: Alloy C276
316L
Rhodium - Material process membrane: 316L, AlloyC, Rhodium> Gold
- Measuring cell: 100 mbar…700 bar (1.5 psi…10.500 psi), relative/ absolute

Absolute and gauge pressure Cerabar PMP75
Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids
Predecessor: Cerabar S PMC631, Cerabar S PMP635
- Accuracy: 0,075% + influence of diaphragm seal
- Process temperature: -70°C…400°C
(-94°F…752°F) - Pressure measuring range: 400 mbar…400 bar
(6 psi…6000 psi) - Process pressure / max. overpressure limit: 1050bar (15,200psi)
- Main wetted parts: Alloy C276
316L
Monel
Tantalum
PTFE-Foil - Max. measurement distance: 7000m (22.966ft) H2O
- Material process membrane: 316L, AlloyC, Tantal, Rhodium> Gold, PTFE
- Measuring cell: 400 mbar…400 bar, (6 psi…6000 psi), relative/ absolute

Hydrostatic Level measurement Deltapilot FMB50
Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement
Predecessor: Deltapilot S DB50, Deltapilot S DB50A, Deltapilot S DB50L, Deltapilot S DB50S
- Accuracy: Standard 0.2%
Optional 0.1% - Process temperature: -10°C…100°C (14°F…212°F)
- Pressure measuring range: 100 mbar…10 bar (1.5 psi…150 psi)
- Process pressure / max. overpressure limit: 40 bar (600 psi)
- Main wetted parts: Alloy C
316L
optional coating AuPt - Max. measurement distance?: 100m (328ft) H2O
- Material process membrane: 316L, AlloyC, Gold-Rhodium
- Measuring cell: 100 mbar…10 bar (1.5 psi…150 psi)

Hydrostatic Level measurement Deltapilot FMB51
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Predecessor: Deltapilot S DB51, Deltapilot S DB51A
- Accuracy: Standard 0.2%
Optional 0.1% - Process temperature: -10°C…85°C
(14°F…212°F) - Pressure measuring range: 100 mbar…10 bar
(1.5 psi…150 psi) - Process pressure / max. overpressure limit: 40 bar (600 psi)
- Main wetted parts: Alloy C
316L
optional coating AuPt - Max. measurement distance: 100m (328ft) H2O
- Material process membrane: 316L, AlloyC
Gold-Rhodium - Measuring cell: 100 mbar…10 bar (1.5 psi…150 psi)

Hydrostatic Level measurement Deltapilot FMB52
Pressure sensor with Contite measuring cell for hydrostatic level measurement
Predecessor: Deltapilot S DB52, Deltapilot S DB52A
- Accuracy: Standard 0.2%
Optional 0.1% - Process temperature: PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F - Pressure measuring range: 100 mbar…10 bar
(1.5 psi…150 psi) - Process pressure / max. overpressure limit: 40 bar (600 psi)
- Main wetted parts: Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh - Max. measurement distance: 100 m (328 ft) H2O
- Material process membrane: 316L, AlloyC,
Gold-Rhodium
PE, FEP - Measuring cell: 100 mbar…10 bar (1.5 psi…150 psi)

Hydrostatic Level measurement Deltapilot FMB53
Pressure sensor with Contite measuring cell for hydrostatic level measurement
Predecessor: Deltapilot S DB53, Deltapilot S DB53A
- Accuracy: Standard 0.2%
Optional 0.1% - Process temperature: PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F - Pressure measuring range: 100mbar…10bar
(1.5psi…150psi) - Process pressure / max. overpressure limit: 40 bar (600 psi)
- Main wetted parts: Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh - Max. measurement distance: 100 m (328 ft) H2O
- Material process membrane: 316L, AlloyC,
Gold-Rhodium
PE, FEP - Measuring cell: 100 mbar…10 bar (1.5 psi…150 psi)

Hydrostatic Level measurement Deltapilot FMB70
Highest performance pressure sensor with the Contite cell for hydrostatic level measurement
Predecessor: Deltapilot S DB50, Deltapilot S DB50A, Deltapilot S DB50L, Deltapilot S DB50S
- Accuracy: Standard 0.1%
Optional 0.075% - Process temperature: -10°C…+100°C
(+14°F…+212°F) - Pressure measuring range: 100 mbar…10 bar
(1.5 psi…150 psi) - Process pressure / max. overpressure limit: 40 bar (600 psi)
- Main wetted parts: Alloy C
316L - Max. measurement distance: 100 m (328 ft) H2O
- Material process membrane: 316L, AlloyC,
Gold-Rhodium - Measuring cell: 100 mbar…10 bar (1.5 psi…150 psi)

Differential pressure Deltabar FMD77
Differential pressure transmitter with one diaphragm seal for level measurement
Predecessor: Deltabar S FMD630
- Accuracy: 0,075% + influence of diaphragm seal
- Process temperature: -40°C…400°C (-40°F…752°F)
- Pressure measuring range: 100mbar…16bar
(1.5psi…230 psi) - Process pressure / max. overpressure limit: 160bar (2400 psi)
- Main wetted parts: Alloy C276
316L
Monel
Tantalum - Max. measurement distance: 160m (525ft) H2O
- Material process membrane: 316L, AlloyC, Tantal, Gold-Rhodium, PTFE
- Measuring cell: 100 mbar…16 bar (40 inH20…240 psi)

Differential pressure Deltabar FMD78
Differential pressure transmitter with two diaphragm seals for differential pressure and level
Predecessor: Deltabar S FMD633
- Accuracy: 0,075% + influence of diaphragm seal
- Process temperature: -40°C…400°C (-40°F…752°F)
- Pressure measuring range: 100mbar…40bar
(1.5psi … 600 psi) - Process pressure / max. overpressure limit: 160bar (2400 psi)
- Main wetted parts: Alloy C276
316L
Monel
Tantalum - Max. measurement distance: 400m (1312ft) H2O
- Material process membrane: 316L, AlloyC,
Tantal,
Gold-Rhodium
PTFE - Measuring cell: 100 mbar…40 bar (40 inH2O…600 psi)

Gauge pressure Cerabar PMC11
Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids
Predecessor: Cerabar T PMC131
- Accuracy: 0.5%
- Process temperature: -25 °C…+85 °C (-13 °F…+185 °F)
- Pressure measuring range: +400 mbar…+40 bar (+6 psi…+600 psi)
- Measuring cell +400 mbar…+40 bar (+6 psi…+600 psi)

Gauge pressure Cerabar PMP11
Cost-effective pressure transducer with metal sensor for measurement in gases or liquids
Predecessor: Cerabar T PMP131
- Accuracy: 0.5%
- Process temperature: -25…+85°C (-13…+185°F)
- Pressure measuring range: 400 mbar…+40 bar (6 psi…+600 psi)
- Measuring cell: 400 mbar…+40 bar (6 psi…+600 psi)

Absolute and gauge pressure Ceraphant PTC31B
Cost-effective pressure switch with oil-free ceramic sensor for measurement in gases or liquids
Predecessor: Ceraphant T PTC31
- Measuring cell: +100 mbar….+40 bar (+1.5 psi….600 psi)

Absolute and gauge pressure Ceraphant PTP31B
Cost-effective pressure switch with welded metal sensor for measurement in gases, steams or liquids
Predecessor: Ceraphant T PTP31
- Measuring cell: +400 mbar….+400 bar (+6 psi…+6000 psi)

Absolute and gauge pressure Ceraphant PTP33B
Cost-effective pressure switch with fully welded metal sensor for use in hygienic applications
Predecessor: Ceraphant T PTP35
- Measuring cell: +400 mbar….+40 bar (+6 psi….+600 psi)

Hydrostatic Level measurement Waterpilot FMX11
Simple and reliable level probe for freshwater applications
- Accuracy: pn ≥ 400mbar: 0.35 %
pn < 400mbar: 0.50 % - Process temperature: -10°C…+70°C
(+14°F…+158°F) - Pressure measuring range: 200 mbar…2 bar
(3 psi…29 psi) - Process pressure / max. overpressure limit: 10 bar (145 psi)
- Main wetted parts: 316L
- Max. measurement distance: 20 m H2O
(66 ft H2O) - Material process membrane: Metal
- Measuring cell:200 mbar…2 bar (3 psi…29 psi)

Hydrostatic Level measurement Waterpilot FMX21
Reliable and robust level probe with ceramic measuring cell and HART
Predecessor: Waterpilot FMX167
- Accuracy: 0.2%
0.1% (optional) - Process temperature: -10°C…70°C (14°F…158°F)
Diameter 29 mm (1.14″): 0°C…50°C (32°F…122°F) - Pressure measuring range: 100 mbar…20 bar (1.5 psi…300 psi)
- Main wetted parts: Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
Extension cable: PE, PUR, FEP - Max. measurement distance: 200 m H2O (656 ft H2O)
- Measuring cell: 100mbar…20bar (1.5psi…300psi)

Deltabar PMD78B - differential pressure transmitter
Minimizes ambient and process temperature effects on your measurement thanks to the TempC membrane
- Accuracy: Standard:
up to 0.1 % - Process temperature:: -40°C…+400°C (-40°F…+752°F)
- Pressure measuring range: 100 mbar…40 bar (1.5psi…600 psi)
- Main wetted parts: 316L, AlloyC,
Tantal, Monel, PTFE, Gold - Material process membrane: 316L, AlloyC,
Tantal,
Monel
PTFE
Gold - Measuring cell: 100 mbar…40 bar (1.5 psi…600 psi)