Limit Switch Connectors

SC

Connectors for Limit switches to secure watertightness of the edges of the conduits.

Connectors (SC Series)

Connector for Cabtire Cable

Conduit

Applicable cable

Inner diameter (D)
 of seal rubber

External diameter
 of cable

Model

Applicable model

Min.

Max.

JIS B 0202 G1/2

Cabtire cable
 (general-purpose)

7 mm

5.5 mm

7.5 mm

SC-1M

WL-N, WL, D4A-[]N,
 D4B-[]N, ZE, ZV,
 ZV2, XE, XV, XV2

9 mm

7.5 mm

9.5 mm

SC-2M

12.5 mm

11 mm

13 mm

SC-3M

14 mm

12 mm

14 mm

SC-4M

11 mm

9 mm

11 mm

SC-5M

Cabtire cable
 (anti-corrosive)

7 mm

5.5 mm

7.5 mm

SC-21

9 mm

7.5 mm

9.5 mm

SC-22

12.5 mm

11 mm

13 mm

SC-23

14 mm

12 mm

14 mm

SC-24

11 mm

9 mm

11 mm

SC-25

1/2-14NPT

Cabtire cable

7 mm

5.5 mm

7.5 mm

SC-1PT

D4A-[]N

9 mm

7.5 mm

9.5 mm

SC-2PT

12.5 mm

11 mm

13 mm

SC-3PT

14 mm

12 mm

14 mm

SC-4PT

11 mm

9 mm

11 mm

SC-5PT

Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and
           therefore sealing tape is not necessary to ensure a proper seal.

Simple Connector

(Not Suitable for Locations Subject to Oil or Water) 

Conduit

Applicable
 cable

Inner diameter (D)
 of seal rubber

External diameter
 of cable

Model

Applicable model

Min.

Max.

JIS B 0202 G1/2

Cabtire cable

10.6 mm

8.5 mm

10.5 mm

SC-P2

WL-N, WL, D4A-[]N, D4B-[]N,
 ZE, ZV, ZV2, XE, XV, XV2

Pg13.5

9.6 mm

7.5 mm

9.5 mm

SC-P3

WL[]-G

JIS B 0202 G1/2

9 mm

7.5 mm

9 mm

SC-6

WL-N, WL, D4A-[]N, D4N *,
 D4N-[]R *, D4B-[]N, ZE, ZV,
 ZV2, XE, XV, XV2

Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which
           have metal casings.
           Models marked with an asterisk (*) however, can only be used with resin connectors.

SC-[]F[] FA Connectors

 image

FA Connectors

Model

Number of
 conductors

Voltage specification

Size of conduit

Size of crimp terminal

Applicable model

SC-2F

2

125 VDC

JIS B 0202
 G½

M4

WL-N,
 WL

SC-2FAD

2

250 VAC

SC-4F4D

4

125 VDC

SC-4F4AD

4

250 VAC

Connecting Cables

image

Voltage specification

Number of conductors

Cable length

Model

AC

2

2 m

XS2F-A421-DB0-F

5 m

XS2F-A421-GB0-F

4

2 m

XS2F-A421-D90-F

5 m

XS2F-A421-G90-F

DC

2

2 m

XS2F-D421-DD0

5 m

XS2F-D421-GD0

4

2 m

XS2F-D421-D80-F

5 m

XS2F-D421-G80-F