Temperature

Endress+Hauser Temperature products is one of the world’s leading providers of measuring instruments and complete systems for Temperature products.

Products List

TAF12T High temperature TC thermometer

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

  • Accuracy: class 2 acc. to IEC 60584
  • Max. process pressure (static): at 20 °C: 1 bar (15 psi)
  • Operating temperature range: Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)
  • Max. immersion length on request: up to 3.500,00 mm (137,80”)

 

TC65 Explosion-proof thermocouple thermometer

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

Predecessor: TC76

Successor: iTHERM TM111, iTHERM TM101

  • Accuracy: class 1 acc. to IEC 60584
    Response time: depending on configuration
    t50 = 3 s
    t90 = 7 s
  • Max. process pressure (static): at 20 °C: 80 bar (1,160 psi)
  • Operating temperature range: Type K:
    max. 1.100 °C
    (max. 2.012 °F)
    Type J:
    max. 800 °C
    (max. 1.472 °F)
  • Max. immersion length on request: up to 30.000,00 mm (1.181,10”)

 

TC66 Explosion-proof TC Thermometer

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

Predecessor: TC70, TC75, Omnigrad S TSC266

  • Accuracy: class 1 acc. to IEC 60584
  • Response time: depending on configuration
    t50 = 3 s
    t90 = 7 s
  • Max. process pressure (static): at 20 °C: 500 bar (7.252 psi)
  • Operating temperature range: Type K:
    max. 1.100 °C
    (max. 2.012 °F)
    Type J:
    max. 800 °C
    (max. 1.472 °F)
  • Max. immersion length on request: up to 5.000,00 mm (196,85”)

 

TH11 Modular RTD thermometer, US style

Best in class temperature measurement technology for general applications

  • Accuracy: class A acc. to IEC 60751
    class B acc. to IEC 60751
  • Response time: 63% rt = 2,0 s
  • Max. process pressure (static): at 20°C: 250 bar (3.626 psi)
    depends on configuration
  • Operating temperature range: PT 100:
    -200 °C …600 °C
    (-328 °F …1.112 °F)
  • Max. immersion length on request: up to 96″ (2439 mm) others on request

 

TH12 US style RTD sensor, cable probe

Trend-setting, highly modular and intrinsically safe RTD or TC thermometer – for a wide range of industrial applications

Predecessor: Thermocouple TC12, Thermocouple TC10, Thermocouple TC88, Thermocouple TC13, Thermocouple TC61, Thermocouple TC63, Thermocouple TC62, RTD-Assembly S.A. Style TLSR5, TC-Assembly S.A.Style TLSC5, Thermocouple TMT162C, Thermocouple TMT142C, RTD Thermometer TMT142R, RTD Thermometer TR13, RTD Thermometer TR12, RTD Thermometer TR11, RTD Thermometer TR10, RTD Thermometer TMT162R, RTD Thermometer TR88, RTD Thermometer TR61, RTD Thermometer TR63, Thermocouple TR62, RTD Thermometer TSM187, RTD Thermometer TST187, TST10

  • Accuracy: Class AA acc. to IEC 60751
    Class A acc. to IEC 60751
    Class B acc. to IEC 60751
    Class special or standard acc. to ASTM E230
    Class 1 or 2 acc. to IEC 60584-2
  • Response time: fastest response time with thermowell t90 starting at below 10 s
    depending on configuration
  • Max. process pressure (static): depending on the configuration up to 100 bar
  • Operating temperature range: PT100 TF StrongSens:
    -50 °C …500 °C
    (-58 °F …932 °F)
    PT100 QuickSensTF:
    -50 °C …200 °C
    (-58 °F …392 °F)
    PT100 WW:
    -200 °C …600 °C
    (-328 °F …1.112 °F)
    PT100 TF:
    -50 °C …400 °C
    (-58 °F …752 °F)
    Typ K:
    max. 1.100 °C
    (max. 2.012 °F)
    Typ J:
    max. 800 °C
    (max. 1.472 °F)
    Typ N:
    max. 1.100 °C
    (max. 2.012 °F)
  • Max. immersion length on request: up to 4.500,0 mm (177”)

 

TH15 Modular RTD thermometer, US style

Best in class temperature measurement for general applications

  • Accuracy: class A acc. to IEC 60751
    class B acc. to IEC 60751
  • Max. process pressure (static): class AA acc. to IEC 60751
    class A acc. to IEC 60751
    class B acc. to IEC 60751
  • Operating temperature range: PT100 WW:
    -200 °C … 600 °C
    (-328 °F … 1.112 °F)
    StrongSens:
    -50 °C … 500 °C
    (-58 °F … 932 °F)
    PT100 TF:
    -50 °C … 200 °C
    (-58 °F … 392 °F)
  • Max. immersion length on request: up to 41″ (1041 mm) others on request

 

iTHERM TM402 Imperial Hygienic Thermometer, US style

For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

Predecessor: U.S. Style RTD-Assembly TH17, U.S. Style RTD-Assembly TH18

iTHERM TMS11 MultiSens Linear Multipoint

Modular straight TC and RTD multipoint with primary thermowell

  • Accuracy: class 1 acc. to IEC 60584
    class Special ASTM E230 and ANSI MC 96.1
    IEC60751 Class A
    IEC60751 Class AA
  • Response time: depending on configuration:
    TC:
    t50 = 21 s
    t90 = 52 s
    RTD:
    t50 = 42 s
    t90 = 108 s
  • Max. process pressure (static): at 20 °C: 240 bar (3481 psi)
  • Operating temperature range: Type K:
    max. 1.070 °C
    (max. 1.958 °F)
    Type J:
    max. 520 °C
    (max. 968 °F)
    Type N:
    max. 1.100 °C
    (max. 2.012 °F)
    Pt100 WW:
    -200…600 °C
    (-328…1.112 °F)
    Pt100 TF:
    -50…400 °C
    (-58…752 °F)
  • Max. immersion length on request: up to 15.000,00 mm (590”)

 

iTHERM TMS12 MultiSens Linear Multipoint

Modular straight TC and RTD multipoint thermometer with primary thermowell

  • Accuracy: class 1 acc. to IEC 60584
    class Special ASTM E230 and ANSI MC 96.1
    IEC60751 Class A
    IEC60751 Class AA
  • Response time: depending on configuration:
    TC:
    t50 = 21 s
    t90 = 52 s
    RTD:
    t50 = 42 s
    t90 = 108 s
  • Max. process pressure (static): at 20 °C: 240 bar (3481 psi)
  • Operating temperature range: Type K:
    max. 1.070 °C
    (max. 1.958 °F)
    Type J:
    max. 520 °C
    (max. 968 °F)
    Type N:
    max. 1.100 °C
    (max. 2.012 °F)
    Pt100 WW:
    -200…600 °C
    (-328…1.112 °F)
    Pt100 TF:
    -50…400 °F
    (-58…752 °F)
  • Max. immersion length on request: up to 15.000,00 mm (590”)

 

iTHERM TMS21 MultiSens Slim Multipoint

Low invasive bendable TC multipoint thermometer for Petrochemical and Chemical applications

  • Accuracy: class 2 acc. to IEC 60584
    ASTM E230 and ANSI MC 96.1
  • Response time: t50 = 3 s
    t90 = 9 s
  • Max. process pressure (static): at 20 °C: 90 bar (1305 psi)
  • Operating temperature range: Type K:
    max. 920 °C
    (max. 1.688 °F)
    Type J:
    max. 440 °C
    (max. 824 °F)
    Type N:
    max. 920 °C
    (max. 1.688 °F)
    Type E:
    max. 510 °C
    (max. 950 °F)
  • Max. immersion length on request: up to 13.000,00 mm (511,81”)

 

iTEMP TMT84 Temperature head transmitter

Transformation of sensor signals into standardized digital output signals for all industries

Predecessor: iTEMP PA TMT184, TMD834

  • Accuracy: (Pt100) <= 0,1 K, (Pt100) <= 0,18 °F

 

iTEMP TMT85

Temperature head transmitter
Transformation of sensor signals into standardized digital output signals for all industries

  • Accuracy: (Pt100) <= 0,1 K, (Pt100) <= 0,18 °F

 

TR15 Modular RTD thermometer

Robust temperature measurement technology especially for gas and steam applications

Predecessor: TST141, TST140

  • Accuracy: class A acc. to IEC 60751
    class AA acc. to IEC 60751
  • Response time: depending on configuration
  • Max. process pressure (static): at 20 °C: 400 bar (5.802 psi)
  • Operating temperature range: PT100 TF StrongSens:
    -50 °C …500 °C
    (-58 °F …932 °F)
    PT100 WW:
    -200 °C …600 °C
    (-328 °F …1.112 °F)
    PT100 TF:
    -50 °C …400 °C
    (-58 °F …752 °F)
  • Max. immersion length on request: up to 30.000,00 mm (1.181,10”)

 

TR65 Explosion-proof Pt100 Thermometer

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

Predecessor: TR76

Successor: iTHERM TM111, iTHERM TM101

  • Accuracy: class A acc. to IEC 60751
    class AA acc. to IEC 60751
    Response time: t50 = 2 s
    t90 = 5 s
  • Max. process pressure (static): at 20 °C: 80 bar (1.160 psi)
  • Operating temperature range: PT100 TF StrongSens:
    -50 °C …500 °C
    (-58 °F …932 °F)
    PT100 WW:
    -200 °C …600 °C
    (-328 °F …1.112 °F)
    PT100 TF:
    -50 °C …400 °C
    (-58 °F …752 °F)
  • Max. immersion length on request: up to 30.000,00 mm (1.181,10”)

 

TSC310 Thermocouple sensor, cable probe

Cost efficient thermocouple sensor designed for use in many process and laboratory applications

Predecessor: TC-Assembly S.A.Style TLSC2

  • Accuracy: class 2 acc. to IEC 60584
  • Response time: t50 = 1 s
    t90 = 2 s
  • Max. process pressure (static): at 20 °C: 25 bar (363 psi)
    Operating temperature range: Type K:
    max. 1.100 °C
    (max. 2.012 °F)
    Type J:
    max. 750 °C
    (max. 1.382 °F)
  • Max. immersion length on request: up to 100.000,00 mm (3.937,01”)

 

TST602

Cost efficient Pt100 sensor for use in many process and laboratory applications

Predecessor: RTD-Assembly S.A. Style TLSR2

  • Accuracy: class A acc. to IEC 60751
    class B acc. to IEC 60751
    class AA acc. to IEC 60751
  • Response time: t50 = 3 s
    t90 = 6 s
  • Max. process pressure (static): at 20°C: up to 75 bar (depending on the process connection)
  • Operating temperature range: PT 100:
    -50 °C …400 °C
    (-58 °F …752 °F)
  • Max. immersion length on request: up to 10.000,00 mm (393,70”)

 

TST90 Modular RTD thermometer

Comprehensive and common temperature measurement technology for almost all branches of industry

  • Accuracy: +/- 0.05 K (refering to delta-T)
  • Response time: depending on configuration
    t50 = 10 s
    t90 = 31 s
  • Max. process pressure (static): at 20 °C: 50 bar (725 psi)
  • Operating temperature range: PT 100:
    -40 °C …120 °C
    (-40 °F …248 °F)
  • Max. immersion length on request: up to 4.000,00 mm (157,48”)

 

iTHERM TT412 Imperial Hygienic Thermowell, US Style

Designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

Predecessor: U.S. Style thermowell TU67

  • Max. process pressure (static): 40 bar (580 psi)
  • Maximum standard immersion lengthL: 48″ (1.219 mm)

 

TW251 Protection tube for temperature sensors

The protection tube with built-in compression fitting allows varying types of probes to be applied

Predecessor: TA250

  • Max. process pressure (static): 50 bar (725 psi)
  • Maximum standard immersion length: 4.000 mm (157,48″)
  • Max. immersion length on request: 10.000 mm (393,7″)

 

iTHERM TrustSens Bluetooth and WirelessHART integration

Comfortable temperature measurement solution – 100% compliance, 0% effort

  • Easy accessible calibration status
  • Cost reduction by saving calibration costs and reducing calibration cycles.
  • Risk reduction and elimination of undetected failures:
  • Higher process transparency
  • Higher product safety

iTHERM TrustSens self-calibration Monitoring

Automated temperature measurement solution – 100% compliance, 0% effort
Reliable & easy:

  • Cost reduction by saving calibration costs and reducing calibration cycles
  • All required components in one bundle, nothing is forgotten

100% compliance and audit-proof documentation:

  • Fully traceable calibration with automated documentation
  • Tamper-proof data storage according to FDA 21 CFR Part 11
  • Predictive maintenance
  • Calibration with timestamp

Risk reduction and elimination of undetected failures:

  • Higher process transparency
  • Higher product safety

iTHERM applications with limited access

iTHERM TM131 thermometer with remote fieldhousing containing a iTEMP TMT82 HART transmitter and display for applications with limited access

Comfortable handling and read-out

  • Optimized readability of display
  • Easy access for maintenance
  • Mounting of the transmitter in specified temperature range

T53 Explosion proof TC thermometer, US style

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: depending on configuration
    63% rt = 15,0 s
  • Max. process pressure (static): Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 22.5″ (571 mm) others on request

 

iTHERM TM412 Imperial Hygienic Thermometer, US style

For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

Predecessor: U.S. Style RTD-Assembly TH17, U.S. Style RTD-Assembly TH18, U.S. Style RTD-Assembly TH27

  • Accuracy: class B acc. to IEC 60751
    class A acc. to IEC 60751
    class AA acc. to IEC 60751
  • Response time: depending on configuration
    QuickSens: t90 = 1,5 s
    StrongSens: t90 = 9,5 s
  • Max. process pressure (static): at 20 °C: 40 bar (580 psi)
  • Operating temperature range: PT100 WW:
    -200 °C … 600 °C
    (-328 °F … 1.112 °F)
    StrongSens:
    -50 °C … 500 °C
    (-58 °F … 932 °F)
    QuickSens:
    -50 °C … 200 °C
    (-58 °F … 392 °F)
    PT100 TF:
    -50 °C … 200 °C
    (-58 °F … 392 °F)
  • Max. immersion length on request: 48″

 

T54 Explosion proof TC thermometer, US style

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: depending on configuration
    63% rt = 15 s
  • Max. process pressure (static): at 20°C : 500bar (7.252 psi)
    depends on configuration
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 22.5″ (571 mm) others on request

 

TA575 Barstock thermowell

Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.

Successor: iTHERM TT151

  • Max. process pressure (static): 500 bar (7252 psi)
  • Maximum standard immersion length: 1000 mm (39,37″)
  • Max. immersion length on request: 5.000 mm (196,85″)

 

TAF12S High temperature TC thermometer

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

  • Accuracy: class 2 acc. to IEC 60584
  • Max. process pressure (static): at 20 °C: 1 bar (15 psi)
  • Operating temperature range: Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0° C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)
  • Max. immersion length on request: up to 2.500,00 mm (98,43”)

 

TH51 Modular TC thermometer, US style

Best in class temperature measurement technology for general applications

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: 63% rt = 0.3 s
  • Max. process pressure (static): at 20°C: 250 bar (3.626 psi)
    depends on configuration
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 96″ (2.438 mm) others on request

 

TH52 US style thermocouple sensor, cable probe

Cost efficient TC sensor designed for use in many process and laboratory applications

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: 63% rt = 0.3 s
  • Max. process pressure (static): at 20°C: 40 bar (580 psi)’
    depends on configuration
  • Operating temperature range: Type T:
    -270 °C … 370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 96″ (2438 mm) others on request

 

TH53 Modular TC thermometer, US style

Best in class temperature measurement technology for general applications

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: depending on configuration
    63% rt = 15 s
  • Max. process pressure (static): at 20°C: 100 bar (1.450psi)
    depends on configuration
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 24” (609 mm) others on request

 

TH54 Modular TC thermometer, US style

Best in class temperature measurement technology for general applications

  • Accuracy: Standard acc. to ASTM E-230
    Special acc. to ASTM E-230
  • Response time: depending on configuration
    63% rt = 15,0 s
  • Max. process pressure (static): at 20°C: 500 bar (7252 psi)
    depends on configuration
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C … 720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C … 820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 24” (609 mm) others on request

 

TH55 Modular TC thermometer, US style

Comprehensive and common temperature measurement technology for almost all branches of industry

  • Accuracy: class 1 acc. to IEC 60584
    class 2 acc. to IEC 60584
  • Response time: 63% rt = 1,3 s
  • Max. process pressure (static): at 20 °C: 100 bar (1.450 psi)
  • Operating temperature range: Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)
  • Max. immersion length on request: up to 30″ (762 mm) others on request

 

iTEMP TMT182B temperature transmitter

iTEMP TMT182B head transmitter with HART® protocol for universal use

  • Accuracy: (Pt100, -50…200 °C) <= 0,14 K (Pt100, -58…392 °F) <= 0,25 °F

 

TT511 Industrial thermowell

For Oil & Gas applications. Vanstone type, design with collar flange

  • Max. process pressure (static): depending on process connection up to 2500 lbs
  • Maximum standard immersion length: 500 mm (19,69″)
  • Max. immersion length on request: 500 mm (19,69″)

 

Thermophant T TTR31 Temperature switch

Compact and cost-saving for safe monitoring of process temperatures

  • Accuracy: -50…75 °C: <0,5 K
    (-58…167 °F: <0,9 °F)
    75…150 °C: <0,65 K
    (167…302 °F: <1,2 °F)
  • Operating temperature range: -50…150 °C (-58…302 °F)

 

Thermophant T TTR35 Temperature switch

Compact and cost-saving for safe monitoring of process temperatures in hygienic applications

  • Accuracy: -50…75 °C: <0,5 K
    (-58…167 °F: <0,9 °F)
    75…150 °C: <0,65 K
    (167…302 °F: <1,2 °F)
  • Operating temperature range:-50…150 °C (-58…302 °F)

 

TW15 Barstock thermowell

Thermowell made of drilled barstock material. Mainly used in heavy duty or industrial applications

Predecessor: TA573, TA574

Successor: iTHERM TT151

  • Max. process pressure (static): 400 bar (5802 psi)
  • Maximum standard immersion length: 250 mm (9,84″)
  • Max. immersion length on request: 400 mm (15,75″)

 

TA414 Protection tube for temperature sensors

For use in medium duty general applications, mainly to protect the insert from chemical corrosion

  • Max. process pressure (static): 50 bar (725 psi)
  • Maximum standard immersion length: 4.000 mm (157,48″)
  • Max. immersion length on request: 10.000 mm (393,7″)

 

TA550 Barstock thermowell

Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.

Successor: iTHERM TT151

  • Max. process pressure (static): 500 bar (7252 psi)
  • Maximum standard immersion length: 900 mm (35,43″)
  • Max. immersion length on request: 5.000 mm (196,85″)

 

TA555 Barstock thermowell

Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.

Successor: iTHERM TT151

  • Max. process pressure (static): 500 bar (7252 psi)
  • Maximum standard immersion length: 900 mm (35,43″)
  • Max. immersion length on request: 5.000 mm (196,85″)