TAF12T High temperature TC thermometer
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
- Accuracy: class 2 acc. to IEC 60584
- Max. process pressure (static): at 20 °C: 1 bar (15 psi)
- Operating temperature range: Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F) - Max. immersion length on request: up to 3.500,00 mm (137,80”)
TC65 Explosion-proof thermocouple thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
Predecessor: TC76
Successor: iTHERM TM111, iTHERM TM101
- Accuracy: class 1 acc. to IEC 60584
Response time: depending on configuration
t50 = 3 s
t90 = 7 s - Max. process pressure (static): at 20 °C: 80 bar (1,160 psi)
- Operating temperature range: Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F) - Max. immersion length on request: up to 30.000,00 mm (1.181,10”)
TC66 Explosion-proof TC Thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
Predecessor: TC70, TC75, Omnigrad S TSC266
- Accuracy: class 1 acc. to IEC 60584
- Response time: depending on configuration
t50 = 3 s
t90 = 7 s - Max. process pressure (static): at 20 °C: 500 bar (7.252 psi)
- Operating temperature range: Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F) - Max. immersion length on request: up to 5.000,00 mm (196,85”)
TH11 Modular RTD thermometer, US style
Best in class temperature measurement technology for general applications
- Accuracy: class A acc. to IEC 60751
class B acc. to IEC 60751 - Response time: 63% rt = 2,0 s
- Max. process pressure (static): at 20°C: 250 bar (3.626 psi)
depends on configuration - Operating temperature range: PT 100:
-200 °C …600 °C
(-328 °F …1.112 °F) - Max. immersion length on request: up to 96″ (2439 mm) others on request
TH12 US style RTD sensor, cable probe
Trend-setting, highly modular and intrinsically safe RTD or TC thermometer – for a wide range of industrial applications
Predecessor: Thermocouple TC12, Thermocouple TC10, Thermocouple TC88, Thermocouple TC13, Thermocouple TC61, Thermocouple TC63, Thermocouple TC62, RTD-Assembly S.A. Style TLSR5, TC-Assembly S.A.Style TLSC5, Thermocouple TMT162C, Thermocouple TMT142C, RTD Thermometer TMT142R, RTD Thermometer TR13, RTD Thermometer TR12, RTD Thermometer TR11, RTD Thermometer TR10, RTD Thermometer TMT162R, RTD Thermometer TR88, RTD Thermometer TR61, RTD Thermometer TR63, Thermocouple TR62, RTD Thermometer TSM187, RTD Thermometer TST187, TST10
- Accuracy: Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 - Response time: fastest response time with thermowell t90 starting at below 10 s
depending on configuration - Max. process pressure (static): depending on the configuration up to 100 bar
- Operating temperature range: PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F) - Max. immersion length on request: up to 4.500,0 mm (177”)
TH15 Modular RTD thermometer, US style
Best in class temperature measurement for general applications
- Accuracy: class A acc. to IEC 60751
class B acc. to IEC 60751 - Max. process pressure (static): class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751 - Operating temperature range: PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) - Max. immersion length on request: up to 41″ (1041 mm) others on request
iTHERM TM402 Imperial Hygienic Thermometer, US style
For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Predecessor: U.S. Style RTD-Assembly TH17, U.S. Style RTD-Assembly TH18
iTHERM TMS11 MultiSens Linear Multipoint
Modular straight TC and RTD multipoint with primary thermowell
- Accuracy: class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA - Response time: depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s - Max. process pressure (static): at 20 °C: 240 bar (3481 psi)
- Operating temperature range: Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200…600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F) - Max. immersion length on request: up to 15.000,00 mm (590”)
iTHERM TMS12 MultiSens Linear Multipoint
Modular straight TC and RTD multipoint thermometer with primary thermowell
- Accuracy: class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA - Response time: depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s - Max. process pressure (static): at 20 °C: 240 bar (3481 psi)
- Operating temperature range: Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200…600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °F
(-58…752 °F) - Max. immersion length on request: up to 15.000,00 mm (590”)
iTHERM TMS21 MultiSens Slim Multipoint
Low invasive bendable TC multipoint thermometer for Petrochemical and Chemical applications
- Accuracy: class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1 - Response time: t50 = 3 s
t90 = 9 s - Max. process pressure (static): at 20 °C: 90 bar (1305 psi)
- Operating temperature range: Type K:
max. 920 °C
(max. 1.688 °F)
Type J:
max. 440 °C
(max. 824 °F)
Type N:
max. 920 °C
(max. 1.688 °F)
Type E:
max. 510 °C
(max. 950 °F) - Max. immersion length on request: up to 13.000,00 mm (511,81”)
iTEMP TMT84 Temperature head transmitter
Transformation of sensor signals into standardized digital output signals for all industries
Predecessor: iTEMP PA TMT184, TMD834
- Accuracy: (Pt100) <= 0,1 K, (Pt100) <= 0,18 °F
iTEMP TMT85
Temperature head transmitter
Transformation of sensor signals into standardized digital output signals for all industries
- Accuracy: (Pt100) <= 0,1 K, (Pt100) <= 0,18 °F
TR15 Modular RTD thermometer
Robust temperature measurement technology especially for gas and steam applications
Predecessor: TST141, TST140
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
- Max. process pressure (static): at 20 °C: 400 bar (5.802 psi)
- Operating temperature range: PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 30.000,00 mm (1.181,10”)
TR65 Explosion-proof Pt100 Thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
Predecessor: TR76
Successor: iTHERM TM111, iTHERM TM101
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time: t50 = 2 s
t90 = 5 s - Max. process pressure (static): at 20 °C: 80 bar (1.160 psi)
- Operating temperature range: PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 30.000,00 mm (1.181,10”)
TSC310 Thermocouple sensor, cable probe
Cost efficient thermocouple sensor designed for use in many process and laboratory applications
Predecessor: TC-Assembly S.A.Style TLSC2
- Accuracy: class 2 acc. to IEC 60584
- Response time: t50 = 1 s
t90 = 2 s - Max. process pressure (static): at 20 °C: 25 bar (363 psi)
Operating temperature range: Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 750 °C
(max. 1.382 °F) - Max. immersion length on request: up to 100.000,00 mm (3.937,01”)
TST602
Cost efficient Pt100 sensor for use in many process and laboratory applications
Predecessor: RTD-Assembly S.A. Style TLSR2
- Accuracy: class A acc. to IEC 60751
class B acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: t50 = 3 s
t90 = 6 s - Max. process pressure (static): at 20°C: up to 75 bar (depending on the process connection)
- Operating temperature range: PT 100:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 10.000,00 mm (393,70”)
TST90 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
- Accuracy: +/- 0.05 K (refering to delta-T)
- Response time: depending on configuration
t50 = 10 s
t90 = 31 s - Max. process pressure (static): at 20 °C: 50 bar (725 psi)
- Operating temperature range: PT 100:
-40 °C …120 °C
(-40 °F …248 °F) - Max. immersion length on request: up to 4.000,00 mm (157,48”)
iTHERM TT412 Imperial Hygienic Thermowell, US Style
Designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Predecessor: U.S. Style thermowell TU67
- Max. process pressure (static): 40 bar (580 psi)
- Maximum standard immersion lengthL: 48″ (1.219 mm)
TW251 Protection tube for temperature sensors
The protection tube with built-in compression fitting allows varying types of probes to be applied
Predecessor: TA250
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)
iTHERM TrustSens Bluetooth and WirelessHART integration
Comfortable temperature measurement solution – 100% compliance, 0% effort
- Easy accessible calibration status
- Cost reduction by saving calibration costs and reducing calibration cycles.
- Risk reduction and elimination of undetected failures:
- Higher process transparency
- Higher product safety
iTHERM TrustSens self-calibration Monitoring
Automated temperature measurement solution – 100% compliance, 0% effort
Reliable & easy:
- Cost reduction by saving calibration costs and reducing calibration cycles
- All required components in one bundle, nothing is forgotten
100% compliance and audit-proof documentation:
- Fully traceable calibration with automated documentation
- Tamper-proof data storage according to FDA 21 CFR Part 11
- Predictive maintenance
- Calibration with timestamp
Risk reduction and elimination of undetected failures:
- Higher process transparency
- Higher product safety
iTHERM applications with limited access
iTHERM TM131 thermometer with remote fieldhousing containing a iTEMP TMT82 HART transmitter and display for applications with limited access
Comfortable handling and read-out
- Optimized readability of display
- Easy access for maintenance
- Mounting of the transmitter in specified temperature range
T53 Explosion proof TC thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: depending on configuration
63% rt = 15,0 s - Max. process pressure (static): Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C …1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 22.5″ (571 mm) others on request
iTHERM TM412 Imperial Hygienic Thermometer, US style
For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Predecessor: U.S. Style RTD-Assembly TH17, U.S. Style RTD-Assembly TH18, U.S. Style RTD-Assembly TH27
- Accuracy: class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s - Max. process pressure (static): at 20 °C: 40 bar (580 psi)
- Operating temperature range: PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) - Max. immersion length on request: 48″
T54 Explosion proof TC thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: depending on configuration
63% rt = 15 s - Max. process pressure (static): at 20°C : 500bar (7.252 psi)
depends on configuration - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C … 1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 22.5″ (571 mm) others on request
TA575 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 1000 mm (39,37″)
- Max. immersion length on request: 5.000 mm (196,85″)
TAF12S High temperature TC thermometer
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
- Accuracy: class 2 acc. to IEC 60584
- Max. process pressure (static): at 20 °C: 1 bar (15 psi)
- Operating temperature range: Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0° C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F) - Max. immersion length on request: up to 2.500,00 mm (98,43”)
TH51 Modular TC thermometer, US style
Best in class temperature measurement technology for general applications
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: 63% rt = 0.3 s
- Max. process pressure (static): at 20°C: 250 bar (3.626 psi)
depends on configuration - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 96″ (2.438 mm) others on request
TH52 US style thermocouple sensor, cable probe
Cost efficient TC sensor designed for use in many process and laboratory applications
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: 63% rt = 0.3 s
- Max. process pressure (static): at 20°C: 40 bar (580 psi)’
depends on configuration - Operating temperature range: Type T:
-270 °C … 370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C …1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 96″ (2438 mm) others on request
TH53 Modular TC thermometer, US style
Best in class temperature measurement technology for general applications
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: depending on configuration
63% rt = 15 s - Max. process pressure (static): at 20°C: 100 bar (1.450psi)
depends on configuration - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C … 1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 24” (609 mm) others on request
TH54 Modular TC thermometer, US style
Best in class temperature measurement technology for general applications
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: depending on configuration
63% rt = 15,0 s - Max. process pressure (static): at 20°C: 500 bar (7252 psi)
depends on configuration - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C … 720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C … 820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 24” (609 mm) others on request
TH55 Modular TC thermometer, US style
Comprehensive and common temperature measurement technology for almost all branches of industry
- Accuracy: class 1 acc. to IEC 60584
class 2 acc. to IEC 60584 - Response time: 63% rt = 1,3 s
- Max. process pressure (static): at 20 °C: 100 bar (1.450 psi)
- Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 30″ (762 mm) others on request
iTEMP TMT182B temperature transmitter
iTEMP TMT182B head transmitter with HART® protocol for universal use
- Accuracy: (Pt100, -50…200 °C) <= 0,14 K (Pt100, -58…392 °F) <= 0,25 °F
TT511 Industrial thermowell
For Oil & Gas applications. Vanstone type, design with collar flange
- Max. process pressure (static): depending on process connection up to 2500 lbs
- Maximum standard immersion length: 500 mm (19,69″)
- Max. immersion length on request: 500 mm (19,69″)
Thermophant T TTR31 Temperature switch
Compact and cost-saving for safe monitoring of process temperatures
- Accuracy: -50…75 °C: <0,5 K
(-58…167 °F: <0,9 °F)
75…150 °C: <0,65 K
(167…302 °F: <1,2 °F) - Operating temperature range: -50…150 °C (-58…302 °F)
Thermophant T TTR35 Temperature switch
Compact and cost-saving for safe monitoring of process temperatures in hygienic applications
- Accuracy: -50…75 °C: <0,5 K
(-58…167 °F: <0,9 °F)
75…150 °C: <0,65 K
(167…302 °F: <1,2 °F) - Operating temperature range:-50…150 °C (-58…302 °F)
TW15 Barstock thermowell
Thermowell made of drilled barstock material. Mainly used in heavy duty or industrial applications
Predecessor: TA573, TA574
Successor: iTHERM TT151
- Max. process pressure (static): 400 bar (5802 psi)
- Maximum standard immersion length: 250 mm (9,84″)
- Max. immersion length on request: 400 mm (15,75″)
TA414 Protection tube for temperature sensors
For use in medium duty general applications, mainly to protect the insert from chemical corrosion
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)
TA550 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)
TA555 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)