Temperature
Endress+Hauser Temperature products is one of the world’s leading providers of measuring instruments and complete systems for Temperature products.
Products List

TA556 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA557 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 1000 mm (39,37″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA560 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA562 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA565 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 150 mm (5,91″)
- Max. immersion length on request: 300 mm (11,81″)

TA566 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA571 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 1000 mm (39,37″)
- Max. immersion length on request: 5.000 mm (196,85″)

TA572 Barstock thermowell
Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.
Successor: iTHERM TT151
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 900 mm (35,43″)
- Max. immersion length on request: 5.000 mm (196,85″)

TC15 Modular TC thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Predecessor: Omnigrad S TSC140T
- Accuracy: class 1 acc. to IEC 60584
- Response time: depending on configuration
- Max. process pressure (static): at 20 °C: 400 bar (5.802 psi)
- Operating temperature range: Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 750 °C
(max. 1.382 °F) - Max. immersion length on request: up to 30.000,00 mm (1.181,10”)

TH56 US style thermocouple sensor, with plug connection
Cost efficient thermocouple sensor designed for use in many process and laboratory applications
- Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Response time: 63% rt = 0,3 s
- Max. process pressure (static): Standard acc. to ASTM E-230
Special acc. to ASTM E-230 - Operating temperature range: Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F) - Max. immersion length on request: up to 96″ (2438 mm) others on request

iTEMP TMT127 DIN rail temperature transmitter
Transformation of the sensor signal into a stable and standardized output signal for all industries
- Accuracy: (Pt100, -50…200 °C) <= 0,2 K (Pt100, -58…392 °F) <= 0,4 °F

iTEMP TMT128 DIN rail temperature transmitter
Transformation of the sensor signal into a stable and standardized output signal for all industries
- Accuracy: (Type K) <= 0,5 K (Type K) <=0,9 °F

iTEMP TMT188 Temperature head transmitter
Transformation of the sensor signal into a stable and standardized output signal for all industries
Predecessor: TMC134, TMC138
- Accuracy: (Type K) <= 0,5 K (Type K) <= 0,9 °F

iTEMP TMT80 Temperature head transmitter
Transformation of the sensor signals into stable and standardized output signal for all industries
- Accuracy: (Pt100, -50…250 °C) <= 0,5 K, (Pt100, -58…482 °F) <= 0,9 °F

TU51 Weld-in barstock thermowell, US style
Thermowell with weld-in process connections and round extension
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 24″

TU52 Socket weld barstock thermowell, US style
Thermowell with socket weld process connections and round extension
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 24″

TU53 Threaded barstock thermowell, US style
Thermowell with threaded process connections and hexagonal extension
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 24″
- Max. immersion length on request: Not defined

TU54 Flanged barstock thermowell, US style
Thermowell with flanged process connections and round extension
- Max. process pressure (static): 500 bar (7252 psi)
- Maximum standard immersion length: 24″

TWF11 Protection tube for high temperature assemblies
For steel treatment, concrete furnaces and primaries with very high process temperatures
- Max. process pressure (static): 1 bar (15 psi)
- Maximum standard immersion length: 1.500 mm (59,06″)
- Max. immersion length on request: 4.000 mm (157,48″)

TWF16 Protection tube for high temperature assemblies
For processes with high process temperatures like cement production, steel treatment, incinerators
- Max. process pressure (static): 1 bar (15 psi)
- Maximum standard immersion length: 2.200 mm (86,61″)
- Max. immersion length on request: 4.525 mm (178,15″)

MLTTS00 Modular thermometer with RTD or TC insert
Designed for use in the Oil & Gas industry. For installation in already existing thermowells
- Accuracy: RTD Class A acc. to IEC 60751
TC class 1 acc. To EN 60584 - Response time: depending on configuration
- Max. process pressure (static): depending on Thermowell
- Operating temperature range: PT100:
-50…500 °C
(-58…932 °F)
TC:
max. 1.100 °C
(max. 2.012 °F) - Max. immersion length on request: Not defined

MLTTS01 Modular thermometer with RTD or TC insert
Designed for use in the Oil & Gas industry, with flanged process connection and an extension neck
- Accuracy: RTD Class A acc. to IEC 60751
TC class 1 acc. To EN 60584 - Response time: depending on configuration
- Max. process pressure (static): depending on configuration
- Operating temperature range: PT100:
-50…500 °C
(-58…932 °F)
TC:
max. 600 °C
(max. 1.112 °F) - Max. immersion length on request: Not defined

MLTWS01 Thermowell for temperature sensors
Designed for use in the Oil & Gas industry with flanged process connection
- Maximum standard immersion length: 445 mm, other lenghts on request

Average temperature measurement Prothermo NMT81
Precise average temperature measurement
- Accuracy: +/- 0.032 °C (+/- 0.058 °F)
- Operating temperature range: Options:
-40 °C…+75 °C
(-40 °F…+167 °F)
-55 °C…+235 °C
(-67 °F…+455 °F)
-196 °C…+100 °C
(-321 °F…+212 °F) - Max. immersion length on request: up to 100 m (328 ft)

TA540 Protection tube for temperature sensors
Designed for use with resistance or thermocouple thermometers in heavy duty applications.
Successor: Thermowell TT131
- Max. process pressure (static): 150 bar (2176 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)

TA541 Protection tube for temperature sensors
For use with resistance or thermocouple thermometers principally in heavy duty applications
Successor: Thermowell TT131
- Max. process pressure (static): 150 bar (2176 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)

TEC420 Thermocouple thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Successor: iTHERM TM111, iTHERM TM101
- Accuracy: class 2 acc. to IEC 60584
- Response time: t50 = 3 s
t90 = 7 s - Max. process pressure (static): at 20 °C: 20 bar (290 psi)
- Operating temperature range: -40 °C …1.100 °C
(-40 °F …2.012 °F) - Max. immersion length on request: up to 100.000,00 mm (3.937,01”)

TR10 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Predecessor: TST111, TST121, TST110
Successor: iTHERM TM131, iTHERM TM121
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
- Max. process pressure (static): at 20 °C: 75 bar (1088 psi)
- Operating temperature range: PT100 TF StrongSens: -50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 10.000,00 mm (393,70”)

TR13 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Predecessor: TST13, TST131
Successor: iTHERM TM131, iTHERM TM121
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
- Max. process pressure (static): at 20 °C: 50 bar (725 psi)
- Operating temperature range: PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 10.000,00 mm (393,70”)

TR24 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Predecessor: Omnigrad M TST42, TST420
Successor: iTHERM TM111, iTHERM TM101
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
t50 = 2 s
t90 = 5 sat 20 °C: 40 bar (580 psi) - Operating temperature range: PT 100:
-200 °C …600 °C
(-328 °F …1112 °F) - Max. immersion length on request: up to 10.000,00 mm (393,70”)

TR88 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
Predecessor: Omnigrad S TST280, Omnigrad S TST281, Omnigrad S TST288, TST289
Successor: iTHERM TM131
- Accuracy: class A acc. to IEC 60751
class AA acc. to IEC 60751 - Response time: depending on configuration
- Max. process pressure (static): depending on Thermowell
- Operating temperature range: PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) - Max. immersion length on request: up to 30.000,00 mm (1.181,10”)

TW10 Protection tube
Designed for use in the fine chemicals industry and generally for almost all industrial processes
Predecessor: TA10
Successor: Thermowell TT131
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)

TW11 Protection tube for temperature sensors
Designed for use in the fine chemicals industry and generally for almost all industrial processes
Predecessor: TA11
Successor: Thermowell TT131
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)

TW12 Protection tube for temperature sensors
Designed for use in the fine chemicals industry and generally for almost all industrial processes
Predecessor: TA12
Successor: Thermowell TT131
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)

TW13 Protection tube for temperature sensors
Designed for use in processes with heavy thermal and mechanical stresses
Predecessor: TA13
Successor: Thermowell TT131
- Max. process pressure (static): 50 bar (725 psi)
- Maximum standard immersion length: 4.000 mm (157,48″)
- Max. immersion length on request: 10.000 mm (393,7″)