Pushbutton Switch (Cylindrical 10.5-dia.)

VAQ

Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment

Ratings

Item

Rated voltage (V)

Non-inductive load (A)

Inductive load (A)

Built-in Switch

Resistive load

Lamp load

Inductive load

Motor load

V-15-1A5

125 VAC
 250 VAC

15
 15

2
 2

10
 10

3
 3

8 VDC
 30 VDC
 125 VDC
 250 VDC

15
 10
 0.6
 0.3

4
 4
 0.1
 0.05

10
 10
 0.6
 0.3

6
 4
 0.1
 0.05

Note: 1. The above values are for steady-state currents.
            2. Inductive load: Power factor = 0.4 (AC); time constant = 7 ms (DC).
            3. The lamp load has an inrush current of 10 times the steady-state current.
            4. The motor load has an inrush current of 6 times the steady-state current.
            5. The rated values above are for testing conducted under the following conditions.
                  (1) Ambient temperature: 20 ± 2°C.
                  (2) Ambient humidity: 65% ± 5%RH
                  (3) Operating frequency: 20 times/min.

Characteristics

Operating
 frequency

Mechanical

120 operations/min

Electrical

20 operations/min

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

30 mΩ max. (initial value)

Dielectric
 strength

Between terminals of same polarity

1,000 VAC, 50/60 Hz for 1 minute

Between current-carrying metal part and ground,
 and between each terminal and noncurrent-
 carrying metal part

1,500 VAC, 50/60 Hz for 1 minute

Vibration
 resistance

Malfunction

10 to 55 Hz, 1.5 mm double amplitude *

Shock
 resistance

Destruction

500 m/s2 max.

Malfunction

200 m/s2 max. *

Durability

Mechanical

3,000,000 operations min.

Electrical

100,000 operations min.

Weight

Approx. 12 to 40 g

Inrush
 current

NC

36 A max.

NO

36 A max.

Ambient operating temperature

-25 to 80°C (with no icing or condensation)

Ambient operating humidity

35% to 85%RH

Ambient storage temperature

-25 to 80°C (with no icing or condensation)

Degree of protection

IP00

Electric shock protection class

Class II

PTI (proof tracking index)

175

Pollution degree

3 (IEC947-5-1)

* Malfunction within 1 ms 

Operating Characteristics

Output

1

2

Operating characteristics

Operating force

OF max.

1.96 N

4.90 N

Releasing force

RF min.

0.39 N

0.78 N

Pretravel

PT max.

1.3 mm

1.6 mm

Contact Form

 image

Approved Standard Ratings

The built-in V-15-1A5 Switch is UL and cUL certified.