Product Category

X

General-purpose Basic Switch

X

Direct Current Switch with Built-in Magnetic Blowout

Ratings

Rated voltage

Non-inductive load (A)

Inductive load (A)

 

Resistive load

Lamp load

Inductive load

Motor load

 

NC

NO

NC

NO

NC

NO

NC

NO

 

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

10
 10
 10
 10
 3

3
 3
 3
 3
 1.5

1.5
 1.5
 1.5
 1.5
 0.75

10
 10
 10
 7.5
 2

10
 10
 10
 6
 1.5

5
 5
 5
 5
 2

2.5
 2.5
 2.5
 2.5
 1.5















 

Note: 1. The above values are for the steady-state current.
            2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
            3. Lamp load has an inrush current of 10 times the steady-state current.
            4. Motor load has an inrush current of 6 times the steady-state current.
            5. The above electrical ratings also apply to the AC voltage.
            6. With the reverse-type models (X-10GM[]), the normally closed circuits and normally open circuits are reversed.
            7. The ratings values apply under the following test conditions:
                 (1) Ambient temperature: 20±2°C
                 (2) Ambient humidity: 65±5%RH
                 (3) Operating frequency: 20 operations/min

Contact Specification

Contacts

Material

Silver

 

Gap (standard value)

0.9 mm



Inrush current

NC

30 A max.

 

NO

15 A max.

 

Characteristics

Operating speed

0.1 mm to 1 m/s *1

 

Operating
 frequency

Mechanical

240 operations/min

 

Electrical

20 operations/min

 

Insulation resistance

100 M Ω min. (at 500 VDC)

 

Contact resistance

15 m Ω max. (initial value)

 

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and the ground, and between each terminal and non-current-carrying metal parts




Vibration
 resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *2

 

Shock
 resistance

Destruction

1,000 m/s2 max.

 

Malfunction

300 m/s2 max. *1 *2

 

Durability

Mechanical

1,000,000 operations min.

 

Electrical

100,000 operations min.

 

Degree of protection

IP00

 

Degree of protection
 against electric shock

Class I

 

Proof tracking index (PTI)

175

 

Ambient operating temperature

− 25 ° C to 80 ° C (with no icing)

 

Ambient operating humidity

35% to 85%RH

 

Weight

Approx. 27 to 63 g

 

1. The values are for the pin plunger models. (Contact your OMRON representative for other models.)
 2. Malfunction: 1 ms max.