Cables for I/O Relay Terminals

XW2Z-R

Connect I/O Relay Terminals to I/O Units for Programmable Controllers with one touch.

Type (A side)
Name
I/O Classification
Appearance
Cable length L
(mm)
Models
Loose wire connectins
Cables with Loose
Wires and Crimp Terminals


XW2Z-RY[]C
16 I/O points
1,000
XW2Z-RY100C
1,500
XW2Z-RY150C
2,000
XW2Z-RY200C
3,000
XW2Z-RY300C
5,000
XW2Z-RY500C
Cables with Loose
Wires


XW2Z-RA[]C
16 I/O points
2,000
XW2Z-RA200C
5,000
XW2Z-RA500C
Fujitsu/Otax
connectors

(24 pins)
Cables with Connectors
(1:1)


XW2Z-R[]C
16 I/O points
1,000
XW2Z-R100C
1,500
XW2Z-R150C
2,000
XW2Z-R200C
3,000
XW2Z-R300C
5,000
XW2Z-R500C
Fujitsu/Otax
connectors

(40 pins)
Cables with Connectors
(1:2)


XW2Z-RI[]C-[]

XW2Z-RO[]C-[]
32 input points
(A) 1,000
(B) 750
XW2Z-RI100C-75
(A) 1,500
(B) 1,250
XW2Z-RI150C-125
(A) 2,000
(B) 1,750
XW2Z-RI200C-175
(A) 3,000
(B) 2,750
XW2Z-RI300C-275
(A) 5,000
(B) 4,750
XW2Z-RI500C-475
32 output points
(A) 1,000
(B) 750
XW2Z-RO100C-75
(A) 1,500
(B) 1,250
XW2Z-RO150C-125
(A) 2,000
(B) 1,750
XW2Z-RO200C-175
(A) 3,000
(B) 2,750
XW2Z-RO300C-275
(A) 5,000
(B) 4,750
XW2Z-RO500C-475
Fujitsu/Otax
connectors

(56 pins)
Cables with Connectors
(1:3)


XW2Z-R[]C-[]-[]
48 I/O points
(A) 1,500
(B) 1,250

(C) 1,000
XW2Z-R150C-125-100
(A) 2,000
(B) 1,750

(C) 1,500
XW2Z-R200C-175-150
(A) 3,000
(B) 2,750

(C) 2,500
XW2Z-R300C-275-250
MIL
connectors

(20 pins)
Cables with Connectors
(1:1)

XW2Z-RO[]C
XW2Z-RI[]C
16 I/O points
250
XW2Z-RO25C
500
XW2Z-RO50C
250
XW2Z-RI25C
500
XW2Z-RI50C
MIL
connectors

(40 pins)
Cables with Connectors
(1:2)


XW2Z-RO[]-[]-D1,

XW2Z-RI[]-[]-D1,

XW2Z-RI[]-[]-D2,

XW2Z-RM[]-[]-D1*,

XW2Z-RM[]-[]-D2*
32 I/O points
(A) 500
(B) 250
XW2Z-RO50-25-D1
(A) 750
(B) 500
XW2Z-RO75-50-D1
(A) 1,000
(B)750
XW2Z-RO100-75-D1
(A) 1,500
(B) 1,250
XW2Z-RO150-125-D1
(A) 2,000
(B) 1,750
XW2Z-RO200-175-D1
(A) 3,000
(B) 2,750
XW2Z-RO300-275-D1
(A) 5,000
(B)4,750
XW2Z-RO500-475-D1
(A) 500
(B) 250
XW2Z-RI50-25-D1
(A) 750
(B) 500
XW2Z-RI75-50-D1
(A) 1,000
(B) 750
XW2Z-RI100-75-D1
(A) 1,500
(B) 1,250
XW2Z-RI150-125-D1
(A) 2,000
(B) 1,750
XW2Z-RI200-175-D1
(A) 3,000
(B) 2,750
XW2Z-RI300-275-D1
(A) 5,000
(B)4,750
XW2Z-RI500-475-D1
(A) 500
(B) 250
XW2Z-RI50-25-D2
(A) 750
(B) 500
XW2Z-RI75-50-D2
16 inputs and
16 outputs

(32 I/O points)
(A) 500
(B) 250
XW2Z-RM50-25-D1
(A) 750
(B) 500
XW2Z-RM75-50-D1
(A) 1,000
(B) 750
XW2Z-RM100-75-D1
(A) 1,500
(B) 1,250
XW2Z-RM150-125-D1
(A) 2,000
(B) 1,750
XW2Z-RM200-175-D1
(A) 3,000
(B) 2,750
XW2Z-RM300-275-D1
(A) 5,000
(B)4,750
XW2Z-RM500-475-D1
(A) 500
(B) 250
XW2Z-RM50-25-D2
(A) 750
(B) 500
XW2Z-RM75-50-D2
Mitsubishi
Electric

PLCs with

32-point

connectors

(1:2)


Applicable

models:

For inputs:

AX42, A1SX41,

A1SX42, QX41,

and QX42

For outputs:

AY42, A1SY41,

A1SY42, QY41P,

and QY42P
Mitsubishi Electric PLC
Connecting Cables


XW2Z-RI[]C-[]-MN

XW2Z-RO[]C-[]-MN
32 input points
(A) 1,000
(B) 750
XW2Z-RI100C-75-MN
(A) 1,500
(B) 1,250
XW2Z-RI150C-125-MN
(A) 2,000
(B) 1,750
XW2Z-RI200C-175-MN
(A) 3,000
(B) 2,750
XW2Z-RI300C-275-MN
32 output points
(A) 1,000
(B) 750
XW2Z-RO100C-75-MN
(A) 1,500
(B) 1,250
XW2Z-RO150C-125-MN
(A) 2,000
(B) 1,750
XW2Z-RO200C-175-MN
(A) 3,000
(B) 2,750
XW2Z-RO300C-275-MN
Note: For a connector pin assignment diagram and cable color information, refer to the wiring drawings.