Product Category

Smart Sensor Wide Laser Beam Measurement Sensor (Line Imaging Device Type

ZX-GT

Achieves Micron Accuracy with Longest-in-Class Sensing Distance

Sensor Head

Model

ZX-GT28S11

ZX-GT2840S11

ZX-GT28S41

ZX-GT2840S41

Output type

NPN

PNP

Appearance

Separate type

Integrated type

Separate type

Integrated type

Light source

Visible semiconductor laser diode (wavelength 650 nm, CLASS 1 of EN60825-1/
 IEC60825-1, CLASS II of FDA (21CFR 1040.10 and 1040.11)

Measuring width

28 mm

Sensing distance

0 to 500 mm

40 mm

0 to 500 mm

40 mm

Minimum sensing object

0.5 mm dia. *1

0.2 mm dia.

0.5 mm dia. *1

0.2 mm dia.

Linearity

±0.1%F.S. *2

Resolution

10 μm (number of process values to average: 16) *3

Temperature
 characteristic

0.01%F.S/°C *4

Indicators (emitter)

Laser ON indicator (green), laser alarm indicator (red)

Indicators (receiver)

Optical axis setting indicator (green)

Laser OFF input/sync
 input

ON: Short-circuited with 0 V or 1.5 V max.
 OFF: Open (leakage current: 0.1 mA max.)

ON: Short-circuited with power supply
 voltage or power supply voltage -1.5 V max.
 OFF: Open (leakage current: 0.1 mA max.)

Laser deterioration
 alarm output

NPN open-collector output
 30 VDC 20 mA max.
 Residual voltage 1.2 V max.

PNP open-collector output
 30 VDC 20 mA max.
 Residual voltage 2 V max.

Power consumption
 (emitter)

30 mA max.

Power supply voltage
 (emitter)

24 VDC +10%, -15% ripple (p-p) 10% max.

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Insulation resistance

20 MΩ (at 500 VDC)

Operating ambient
 illumination (emitter)

3,000 lx (incandescent light)

Operating ambient
 illumination (receiver)

1,000 lx (incandescent light) *5

Ambient temperature

Operating: 0 to 40°C Storage: -15 to 50°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Vibration resistance
 (durability)

10 to 150 Hz Single-amplitude: 0.75 mm for 80 min each in X, Y and Z directions

Shock resistance
 (durability)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Degree of protection

IEC60529 IP40

Cable length

2 m

Material

Case: aluminum die-cast, Lens: glass

Weight (packed state)

Approx. 550 g

Approx. 570 g

Approx. 550 g

Approx. 570 g

Accessories

Laser warning labels, Instruction Sheet

F.S.: 28 mm measuring range of receiver
 1. Distance between emitter and receiver: 500 mm, measurement object at 250 mm from receiver. Glass ends of chamfer 0.1 mm or more can be detected in glass edge measurement mode. (at binary level 70%)
 2. Linearity is given to be a typical error with respect to an ideal straight line when the distance between the emitter and receiver is 100 mm and light is blocked at a distance of 50 mm from the receiver. (On the ZX-GT2840[][], the measurement object is measured at a distance of 20 mm from the receiver.)
 3. The amount of fluctuation (±3σ) in the analog output when the distance between the emitter and receiver is 100 mm and a ZX-GTC[][] is connected
 4. Change in the light cutoff value on one side when the distance between the emitter and receiver is 100 mm and the light is half-cutoff at a distance of 50 mm from the receiver (On the ZX-GT2840[][], the measurement object is measured at a distance of 20 mm from the receiver.)
 5. Standard mode (NORM) used

Controller

Model

ZX-GTC11

ZX-GTC41

Output type

NPN

PNP

Measurement cycle *1

1.5 ms (standard mode (NORM)) 0.5 ms (high-speed mode (FAST)) *2

Samples to average

1/2/4/8/16/32/64/128/256/512/1,024/2,048/4,096

Analog output *3

For current output: 4 to 20 mA/F.S., max. load resistance 300 Ω For voltage output:
 ±4 V, (±5 V, 1 to 5 V *4), output impedance 100 Ω

Timing input, bank switching
 input, zero reset input,
 reset input

ON: short-circuited with 0 V or 1.5 V max.
 OFF: Open (leakage current: 0.1 mA max.)

ON: short-circuited with power supply
 voltage or power supply voltage .1.5 V max.
 OFF: Open (leakage current: 0.1 mA max.)

HIGH/PASS/LOW Judgment
 output *5 Sync output *6

NPN open-collector output
 30 VDC 50 mA max.
 Residual voltage 1.2 V max.

PNP open-collector output
 30 VDC 50 mA max.
 Residual voltage 2 V max.

Indicator

Judgment output indicator: HIGH (orange), PASS (green), LOW (orange)
 Main display (red) Sub-display (yellow) Bank 1/2 (orange), zero reset (green)

Main
 functions

Number of
 registered setups

2 banks

Measurement
 Mode

Interrupted beam width measurement, incident beam width measurement, outer
 diameter measurement, center position measurement, IC lead pitch, IC lead width
 judgment, specified edge measurement, wire position measurement, glass edge
 position measurement

Display during
 measurement

Measured value, resolution, threshold, voltage output value, current output value
 (number of display digits can be changed)

Zero reset
 functions

Offset setting of zero reset value, zero reset value memory

Hold

Sample hold, peak hold, bottom hold, peak-to-peak hold, average hold, delay hold

Timer functions

ON delay, OFF delay, one-shot

Adjustment
 functions

Optical Axis adjust mode/light intensityt writing mode, variable binary level, variable
 edge filter, analog output scaling

Calculation

2 Possible on up to two Controllers (Calculation Unit ZX-CAL2 is required for
 connecting Controllers to each other.) A-B, A+B, width

Other

Measurement cycle setting, threshold setting, hysteresis setting, initialization, key lock

Temperature characteristic

0.005%F.S./°C

Current consumption

150 mA max. with power supply voltage of 24 VDC (including receiver) *7

Power supply voltage

24 VDC +10%, .15% ripple (p-p) 10% max.

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Insulation resistance

20 MΩ (at 500 VDC)

Ambient temperature

Operating: 0 to 50°C Storage: .15 to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Vibration resistance
 (durability)

10 to 150 Hz Single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions

Shock resistance (durability)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Degree of protection

IEC60529 IP20

Cable length

2 m

Material

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Weight (packed state)

Approx. 330 g

Accessories

Instruction Sheet

1. A simple average is used in IC lead pitch judgment mode or IC lead width judgment mode. The measurement cycle time can be calculated as follows: Specified measurement cycle time × (Number of samples to average + 1) + 1 ms max. In other measurement modes, a moving average is used. The first measurement cycle time can be calculated as follows: Specified measurement cycle time × (Number of samples to average + 1) + 1 ms max. The second and later measurement cycle times will be equal to the specified measurement cycle time.
 2. The response time in the high-speed mode (FAST) for the IC lead pitch and IC lead width judgment modes is 1 ms.
 3. Current/voltage can be switched using the switch provided on the rear of the Controller.
 4. Can be set by the analog output scaling function.
 5. The error (ERR) state is displayed when all HIGH/PASS/LOW outputs turn OFF.
 6. Normally, wire the sync output wire directly to the emitter’s sync input wire and run the Controller in the standard mode. On an NPN type Controller, use an NPN type emitter, and on a PNP type Controller, use a PNP type emitter. Wiring of the sync wires is not required when the Controller is run in the high-speed mode.
 (Note, however, that the Controller becomes more susceptible to the influence of ambient light in this case.)
 7. The value is 175 mA max. (including receiver) when current output is set.

Interface Unit

Model

ZX-GIF11/-GIF11A

ZX-GIF41/-GIF41A

Compatible Controller

ZX-GTC11

ZX-GTC41

Indicator

Power ON (green), Controller communications (orange), Controller
 communications error (red), RS-232C communications (orange), RS-232C
 communications error (red), binary output (orange)

Communications port

RS-232C (9-pin D-sub connector)

12-bit binary output
 (D11 to D0, GATE)

NPN open-collector output
 30 VDC 20mA max.
 Residual voltage 1.2 V max.

PNP open-collector output
 30 VDC 20 mA max.
 Residual voltage 2 V max.

Power supply voltage

Supplied from Controller (power consumption: 60 mA max.)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Insulation resistance

20 MΩ (at 500 VDC)

Ambient temperature

Operating: 0 to 50°C Storage: .15 to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Vibration resistance (durability)

10 to 150 Hz Single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions

Shock resistance (durability)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Degree of protection

IEC60529 IP20

Cable length

RS-232C 0.5 m, binary output 2 m

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Weight (packed state)

ZX-GIF[]1A: Approx. 550 g
 ZX-GIF[]1: Approx. 330 g

Accessories

ZX-GIF[]1A: Setup Software (CD-ROM), 2 clamps, Instruction Sheet
 ZX-GIF[]1: 2 clamps, Instruction Sheet