Product Category

Multi-function Compact Inverter

3G3MX2-V1

Born to drive machines

Interpreting Model Numbers
3G3MX2 Inverter Models
Note: Inverters with model numbers ending in "-V1" are designed to be used in areas other than China and Europe.
           Refer to the above "Interpreting Model Numbers" for the model numbers for China and Europe.
Rated voltage
Enclosure ratings
Max. applicable motor capacity
Model
CT: Heavy load
VT: Light load
3-phase 200 VAC
IP20
0.1 kW
0.2 kW
3G3MX2-A2001-V1
0.2 kW
0.4 kW
3G3MX2-A2002-V1
0.4 kW
0.75 kW
3G3MX2-A2004-V1
0.75 kW
1.1 kW
3G3MX2-A2007-V1
1.5 kW
2.2 kW
3G3MX2-A2015-V1
2.2 kW
3.0 kW
3G3MX2-A2022-V1
3.7 kW
5.5 kW
3G3MX2-A2037-V1
5.5 kW
7.5 kW
3G3MX2-A2055-V1
7.5 kW
11 kW
3G3MX2-A2075-V1
11 kW
15 kW
3G3MX2-A2110-V1
15 kW
18.5 kW
3G3MX2-A2150-V1
3-phase 400 VAC
IP20
0.4 kW
0.75 kW
3G3MX2-A4004-V1
0.75 kW
1.5 kW
3G3MX2-A4007-V1
1.5 kW
2.2 kW
3G3MX2-A4015-V1
2.2 kW
3.0 kW
3G3MX2-A4022-V1
3.0 kW
4.0 kW
3G3MX2-A4030-V1
4.0 kW
5.5 kW
3G3MX2-A4040-V1
5.5 kW
7.5 kW
3G3MX2-A4055-V1
7.5 kW
11 kW
3G3MX2-A4075-V1
11 kW
15 kW
3G3MX2-A4110-V1
15 kW
18.5 kW
3G3MX2-A4150-V1
1-phase 200 VAC
IP20
0.1 kW
0.2 kW
3G3MX2-AB001-V1
0.2 kW
0.4 kW
3G3MX2-AB002-V1
0.4 kW
0.55 kW
3G3MX2-AB004-V1
0.75 kW
1.1 kW
3G3MX2-AB007-V1
1.5 kW
2.2 kW
3G3MX2-AB015-V1
2.2 kW
3.0 kW
3G3MX2-AB022-V1
Communication Unit
Name
Model
EtherCAT Communication Unit
3G3AX-MX2-ECT
CompoNet Communication Unit
3G3AX-MX2-CRT-E
DeviceNet Communication Unit
3G3AX-MX2-DRT-E
Related Options
Name
Specifications
Model
Regenerative
Braking Units
3-phase 200 VAC
General purpose with Braking resistor
3G3AX-RBU21
High Regeneration purpose with Braking resistor
3G3AX-RBU22
3-phase 400 VAC
General purpose with Braking resistor
3G3AX-RBU41
Braking Resistor
Compact type
Resistor 120 W, 180 Ω
3G3AX-RBA1201
Resistor 120 W, 100 Ω
3G3AX-RBA1202
Resistor 120 W, 5 Ω
3G3AX-RBA1203
Resistor 120 W, 35 Ω
3G3AX-RBA1204
Standard type
Resistor 200 W, 180 Ω
3G3AX-RBB2001
Resistor 200 W, 100 Ω
3G3AX-RBB2002
Resistor 300 W, 50 Ω
3G3AX-RBB3001
Resistor 400 W, 35 Ω
3G3AX-RBB4001
Medium capacity type
Resistor 400 W, 50 Ω
3G3AX-RBC4001
Resistor 600 W, 35 Ω
3G3AX-RBC6001
Resistor 1200 W, 17 Ω
3G3AX-RBC12001
Regenerative Braking Unit and Braking Resistor Combination
Inverter
Usage
conditions
Regenerative
braking unit
Braking resistor
Con-
nec-
tion
con-

figu-
ra-
tion
Restrictions
Volt-
age
Max.
appli-
cable

motor

ca-

pacity
(kW)
Model
%ED
*1

(%)
Ap-
proxi-
mate

braking

torque

(% *2)
Model
Num-
ber
of

units
Model
Num-
ber
of

units
Allowa-
ble
contin-
uous
braking

time

(s)
Min.
con-

nect-
able

resis-
tance
(Ω)
200-V
Class
0.1
3G3MX2-
A2001-V1

3G3MX2-

AB001-V1
3.0%
220%
Built-in
Inverter
 
3G3AX-RBA1201
1
1
20
100
10.0%
220%
 
3G3AX-RBB2001
1
1
30
100
0.2
3G3MX2-
A2002-V1

3G3MX2-

AB002-V1
3.0%
220%
Built-in
Inverter
 
3G3AX-RBA1201
1
1
20
100
10.0%
220%
 
3G3AX-RBB2001
1
1
30
100
0.4
3G3MX2-
A2004-V1

3G3MX2-

AB004-V1
3.0%
220%
Built-in
Inverter
 
3G3AX-RBA1201
1
1
20
100
10.0%
220%
 
3G3AX-RBB2001
1
1
30
100
0.75
3G3MX2-
A2007-V1

3G3MX2-

AB007-V1
3.0%
120%
Built-in
Inverter
 
3G3AX-RBA1201
1
1
20
50
10.0%
120%
 
3G3AX-RBB2001
1
1
30
50
1.5
3G3MX2-
A2015-V1

3G3MX2-

AB015-V1
2.5%
110%
Built-in
Inverter
 
3G3AX-RBA1202
1
1
12
50
10.0%
215%
 
3G3AX-RBC4001
1
1
10
50
2.2
3G3MX2-
A2022-V1

3G3MX2-

AB022-V1
3.0%
150%
Built-in
Inverter
 
3G3AX-RBB3001
1
1
30
35
10.0%
150%
 
3G3AX-RBC4001
1
1
10
35
3.7
3G3MX2-
A2037-V1
3.0%
125%
Built-in
Inverter
 
3G3AX-RBB4001
1
1
20
35
10.0%
125%
 
3G3AX-RBC6001
1
1
10
35
5.5
3G3MX2-
A2055-V1
3.0%
120%
Built-in
Inverter
 
3G3AX-RBB3001
2
2
30
20
10.0%
120%
 
3G3AX-RBC4001
2
2
10
20
7.5
3G3MX2-
A2075-V1
3.0%
125%
Built-in
Inverter
 
3G3AX-RBB4001
2
2
20
17
10.0%
125%
 
3G3AX-RBC6001
2
2
10
17
11
3G3MX2-
A2110-V1
3.0%
90%
Built-in
Inverter
 
3G3AX-RBC12001
1
1
10
17
10.0%
90%
 
3G3AX-RBC12001
1
1
10
17
10.0%
125%
3G3AX-
RBU23

*3
1
3G3AX-RBC6001
3
14
10
4
15
3G3MX2-
A2150-V1
3.0%
110%
Built-in
Inverter
 
3G3AX-RBB3001
5
7
30
10
10.0%
110%
 
3G3AX-RBC4001
5
7
10
10
400-V
Class
0.4
3G3MX2-
A4004-V1
3.0%
220%
Built-in
Inverter
 
3G3AX-RBA1201
2
3
20
180
10.0%
220%
 
3G3AX-RBB2001
2
3
30
180
0.75
3G3MX2-
A4007-V1
3.0%
220%
Built-in
Inverter
 
3G3AX-RBA1201
2
3
20
180
10.0%
220%
 
3G3AX-RBB2001
2
3
30
180
1.5
3G3MX2-
A4015-V1
3.0%
120%
Built-in
Inverter
 
3G3AX-RBA1201
2
3
20
180
10.0%
120%
 
3G3AX-RBB2001
2
3
30
180
2.2
3G3MX2-
A4022-V1
2.5%
150%
Built-in
Inverter
 
3G3AX-RBA1202
2
3
12
100
10.0%
220%
 
3G3AX-RBC4001
2
3
10
100
3.0
3G3MX2-
A4030-V1
2.5%
110%
Built-in
Inverter
 
3G3AX-RBA1202
2
3
12
100
10.0%
215%
 
3G3AX-RBC4001
2
3
10
100
4.0
3G3MX2-
A4040-V1
3.0%
165%
Built-in
Inverter
 
3G3AX-RBB3001
2
3
30
100
10.0%
165%
 
3G3AX-RBC4001
2
3
10
100
5.5
3G3MX2-
A4055-V1
3.0%
120%
Built-in
Inverter
 
3G3AX-RBB3001
2
3
30
70
10.0%
120%
 
3G3AX-RBC4001
2
3
10
70
7.5
3G3MX2-
A4075-V1
3.0%
125%
Built-in
Inverter
 
3G3AX-RBB4001
2
3
20
70
10.0%
125%
 
3G3AX-RBC6001
2
3
10
70
11
3G3MX2-
A4110-V1
3.0%
85%
Built-in
Inverter
 
3G3AX-RBB4001
2
3
20
70
10.0%
85%
 
3G3AX-RBC6001
2
3
10
70
10.0%
120%
3G3AX-
RBU41

*3
1
3G3AX-RBC4001
4
15
10
34
15
3G3MX2-
A4150-V1
3.0%
125%
Built-in
Inverter
 
3G3AX-RBB4001
4
5
20
35
10.0%
125%
 
3G3AX-RBC6001
4
5
10
35
*1 %ED shows the ratio that can be used for braking (deceleration time) among operating time of one task period.
*2 Approximate breaking torque is shown in % of rating torque of the motor (100%).

*3 Please remove the built-in resistor.
Name
Specifications of Inverter
Model
Voltage class
CT: Heavy load
VT: Light load
Radio Noise Filter
3-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-ZCL2
0.2 kW
0.4 kW
0.4 kW
0.75 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
2.2 kW
3.0 kW
3.7 kW
5.5 kW
3G3AX-ZCL1 (3G3AX-ZCL2)
5.5 kW
7.5 kW
7.5 kW
11 kW
3G3AX-ZCL1
11 kW
15 kW
15 kW
18.5 kW
1-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-ZCL2
0.2 kW
0.4 kW
0.4 kW
0.55 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
2.2 kW
3.0 kW
3-phase 400 VAC
0.4 kW
0.75 kW
3G3AX-ZCL2 (3G3AX-ZCL1)
0.75 kW
1.5 kW
1.5 kW
2.2 kW
2.2 kW
3.0 kW
3.0 kW
4.0 kW
4.0 kW
5.5 kW
5.5 kW
7.5 kW
7.5 kW
11 kW
3G3AX-ZCL1
11 kW
15 kW
15 kW
18.5 kW
Input Noise Filter
3-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-NFI21
0.2 kW
0.4 kW
0.4 kW
0.75 kW
0.75 kW
1.1 kW
3G3AX-NFI22
1.5 kW
2.2 kW
3G3AX-NFI23
2.2 kW
3.0 kW
3.7 kW
5.5 kW
3G3AX-NFI24
5.5 kW
7.5 kW
3G3AX-NFI25
7.5 kW
11 kW
3G3AX-NFI26
11 kW
15 kW
3G3AX-NFI27
15 kW
18.5 kW
3G3AX-NFI28
1-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-NFI21
0.2 kW
0.4 kW
0.4 kW
0.55 kW
3G3AX-NFI22
0.75 kW
1.1 kW
3G3AX-NFI23
1.5 kW
2.2 kW
3G3AX-NFI23 *
2.2 kW
3.0 kW
3G3AX-NFI24
3-phase 400 VAC
0.4 kW
0.75 kW
3G3AX-NFI41
0.75 kW
1.5 kW
1.5 kW
2.2 kW
2.2 kW
3.0 kW
3G3AX-NFI42
3.0 kW
4.0 kW
4.0 kW
5.5 kW
3G3AX-NFI43
5.5 kW
7.5 kW
7.5 kW
11 kW
3G3AX-NFI44
11 kW
15 kW
3G3AX-NFI45
15 kW
18.5 kW
3G3AX-NFI46
Output Noise Filter
3-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-NFO01
0.2 kW
0.4 kW
0.4 kW
0.75 kW
0.75 kW
1.1 kW
3G3AX-NFO02
1.5 kW
2.2 kW
2.2 kW
3.0 kW
3G3AX-NFO03
3.7 kW
5.5 kW
5.5 kW
7.5 kW
3G3AX-NFO04
7.5 kW
11 kW
11 kW
15 kW
3G3AX-NFO05
1-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-NFO01
0.2 kW
0.4 kW
0.4 kW
0.55 kW
3G3AX-NFO02
0.75 kW
1.1 kW
1.5 kW
2.2 kW
3G3AX-NFO03
2.2 kW
3.0 kW
3-phase 400 VAC
0.4 kW
0.75 kW
3G3AX-NFO01
0.75 kW
1.5 kW
1.5 kW
2.2 kW
3G3AX-NFO02
2.2 kW
3.0 kW
3.0 kW
4.0 kW
4.0 kW
5.5 kW
3G3AX-NFO03
5.5 kW
7.5 kW
7.5 kW
11 kW
11 kW
15 kW
3G3AX-NFO04
15 kW
18.5 kW
DC Reactor
3-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-DL2002
0.2 kW
0.4 kW
3G3AX-DL2004
0.4 kW
0.75 kW
3G3AX-DL2007
0.75 kW
1.1 kW
3G3AX-DL2015
1.5 kW
2.2 kW
3G3AX-DL2022
2.2 kW
3.0 kW
3G3AX-DL2037
3.7 kW
5.5 kW
3G3AX-DL2055
5.5 kW
7.5 kW
3G3AX-DL2075
7.5 kW
11 kW
3G3AX-DL2110
11 kW
15 kW
3G3AX-DL2150
15 kW
18.5 kW
3G3AX-DL2220
1-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-DL2002
0.2 kW
0.4 kW
3G3AX-DL2004
0.4 kW
0.55 kW
3G3AX-DL2007
0.75 kW
1.1 kW
3G3AX-DL2015
1.5 kW
2.2 kW
3G3AX-DL2022
2.2 kW
3.0 kW
3G3AX-DL2037
3-phase 400 VAC
0.4 kW
0.75 kW
3G3AX-DL4007
0.75 kW
1.5 kW
3G3AX-DL4015 *
1.5 kW
2.2 kW
3G3AX-DL4022
2.2 kW
3.0 kW
3G3AX-DL4037
3.0 kW
4.0 kW
4.0 kW
5.5 kW
3G3AX-DL4055
5.5 kW
7.5 kW
3G3AX-DL4075 *
7.5 kW
11 kW
3G3AX-DL4110 *
11 kW
15 kW
3G3AX-DL4150
15 kW
18.5 kW
3G3AX-DL4220
AC Reactor
3-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-AL2025
0.2 kW
0.4 kW
0.4 kW
0.75 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
3G3AX-AL2055
2.2 kW
3.0 kW
3.7 kW
5.5 kW
3G3AX-AL2110
5.5 kW
7.5 kW
3G3AX-AL2110 *
7.5 kW
11 kW
3G3AX-AL2220
11 kW
15 kW
3G3AX-AL2220 *
15 kW
18.5 kW
3G3AX-AL2330
1-phase 200 VAC
0.1 kW
0.2 kW
3G3AX-AL2025
0.2 kW
0.4 kW
0.4 kW
0.55 kW
0.75 kW
1.1 kW
1.5 kW
2.2 kW
3G3AX-AL2055 *
2.2 kW
3.0 kW
3G3AX-AL2110
3-phase 400 VAC
0.4 kW
0.75 kW
3G3AX-AL4025
0.75 kW
1.5 kW
1.5 kW
2.2 kW
3G3AX-AL4055
2.2 kW
3.0 kW
3.0 kW
4.0 kW
4.0 kW
5.5 kW
3G3AX-AL4110
5.5 kW
7.5 kW
3G3AX-AL4110 *
7.5 kW
11 kW
3G3AX-AL4220
11 kW
15 kW
3G3AX-AL4220 *
15 kW
18.5 kW
3G3AX-AL4330
* Only the CT rating is supported.
Note: When using the Inverter for light load rating, select the model with one size larger capacity (rated current).
Name
Cable length (m)
Model
Digital Operator
-
3G3AX-OP01
Connection cable
1 m
3G3AX-OPCN1
3 m
3G3AX-OPCN3
Recommended EtherCAT Communications Cables
Use Straight STP (shielded twisted-pair) cable of category 5 or higher with double shielding (braiding and aluminum foil tape) for EtherCAT.
Cable with Connectors
Item
Appearance
Recommended
manufacturer
Cable
length

(m) *1
Model
Cable with Connectors on Both Ends
(RJ45/RJ45)

Standard RJ45 plugs type *1

Wire Gauge and Number of Pairs:

AWG26, 4-pair cable

Cable Sheath material: PUR

Cable color: Yellow *2
OMRON
0.3
XS6W-6PUR8SS30CM-YF
0.5
XS6W-6PUR8SS50CM-YF
1
XS6W-6PUR8SS100CM-YF
2
XS6W-6PUR8SS200CM-YF
3
XS6W-6PUR8SS300CM-YF
5
XS6W-6PUR8SS500CM-YF
Cable with Connectors on Both Ends
(RJ45/RJ45)

Rugged RJ45 plugs type *1

Wire Gauge and Number of Pairs:

AWG22, 2-pair cable

Cable color: Light blue
OMRON
0.3
XS5W-T421-AMD-K
0.5
XS5W-T421-BMD-K
1
XS5W-T421-CMD-K
2
XS5W-T421-DMD-K
5
XS5W-T421-GMD-K
10
XS5W-T421-JMD-K
Cable with Connectors on Both Ends
(M12 Straight/RJ45)

Shield Strengthening Connector cable *3

M12/
Smartclick Connectors
Rugged RJ45 plugs type

Wire Gauge and Number of Pairs:

AWG22, 2-pair cable

Cable color: Black
OMRON
0.5
XS5W-T421-BMC-SS
1
XS5W-T421-CMC-SS
2
XS5W-T421-DMC-SS
3
XS5W-T421-EMC-SS
5
XS5W-T421-GMC-SS
10
XS5W-T421-JMC-SS
*1 Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available.
      Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15 m are available.

      For details, refer to Cat.No.G019.

*2 Cables colors are available in blue, yellow, or Green.

*3 For details, contact your OMRON representative.
Cables/Connectors
Wire Gauge and Number of Pairs: AWG24, 4-pair Cable
Item
Appearance
Recommended manufacturer
Model
Cables
---
Hitachi Metals, Ltd.
NETSTAR-C5E SAB 0.5 x 4P CP *
---
Kuramo Electric Co.
KETH-SB *
RJ45 Connectors
---
Panduit Corporation
MPS588-C *
* We recommend you to use above cable and connector together.
Wire Gauge and Number of Pairs: AWG22, 2-pair Cable
Item
Appearance
Recommended manufacturer
Model
Cables
---
Kuramo Electric Co.
KETH-PSB-OMR *
---
JMACS Japan Co., Ltd.
PNET/B *
RJ45 Assembly Connector
OMRON
XS6G-T421-1 *
* We recommend you to use above cable and connector together.
Software
How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
Item
Omron PLC System
Omron Machine Automation Controller System
Controller
CS, CJ, CP, and other series
NJ/NX-series
Inverter
Inverter MX2-series V1 type
Inverter MX2-series V1 type with
EtherCAT
Communication Unit

(Applicable to the CJ series only.)

Inverter MX2-series V1 type with
CompoNet
Communication Unit

Inverter MX2-series V1 type with
DeviceNet
Communication Unit
Inverter MX2-series V1 type
Inverter MX2-series V1 type with
EtherCAT Communication
Unit

Inverter MX2-series V1 type with
CompoNet Communication
Unit

Inverter MX2-series V1 type with
DeviceNet Communication
Unit
Software
FA Integrated Tool Package CX-One
Automation Software Sysmac Studio
FA Integrated Tool Package CX-One
Product
name
Specifications
Model
Stand-
ards
 
Number of
licenses
Media
FA Integrated
Tool Package

CX-One

Ver.4.[]
The CX-One is a comprehensive software package
that integrates Support Software for OMRON PLCs

and components.


CX-One Version.4.[] includes CX-Drive Ver.3.[].
1 license
*
DVD
CXONE-AL01D-V4
-
* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.
Note: For details, refer to the CX-One Catalog (Cat. No. R134), visit your local OMRON website.
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product
name
Specifications
Model
Stand-
ards
 
Number of
licenses
Media
Sysmac
Studio

Standard

Edition

Ver.1.[][]
The Sysmac Studio is the software that provides an
integrated environment for setting, programming,

debugging and maintenance of machine automation

controllers including the NJ/NX-series CPU Units,
NYseries
Industrial PC,
EtherCAT Slave, and the HMI.

The
Sysmac Studio Standard Edition DVD includes
Support Software to set up
EtherNet/IP Units,
DeviceNet slaves, Serial Communications Units, and
Support Software for creating screens on HMIs (
CXDesigner).
-
(Media

only)
Sysmac
Studio

(32 bit)

DVD
SYSMAC-SE200D
-
-
(Media

only)
Sysmac
Studio

(64 bit)

DVD
SYSMAC-SE200D-64
-
1 license
*
---
SYSMAC-SE201L
-
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
Note: For details, refer to the
Sysmac Studio Ver.1.[][] datasheet, visit your local OMRON website.