Small Sealed Switch
D4E-[]N
Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E
Approved Standards
Agency |
Standard |
File No. |
Approved models |
UL |
UL508 |
E76675 |
D4E-[][]20N Switches only except for Indicator- |
CSA |
CSA C22.2 No. 14 |
LR45746 |
D4E-[][]20N Switches only except for Indicator- |
TÜV Rheinland |
EN60947-5-1 |
R9551015 |
Ask your OMRON representative for information on |
CCC (CQC) |
GB/T14048.5 |
Contact your OMRON |
Ask your OMRON representative for information on |
Ratings
Rated voltage |
Standard load |
Micro load |
|||||||||||
Non-inductive load (A) |
Inductive load (A) |
Non-inductive load (A) |
|||||||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
Resistive load |
|||||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
||||
125 VAC |
5 (1) |
1.5 (1) |
3 (1) |
2 (1) |
1 (1) |
0.1 |
|||||||
8 VDC |
5 (1) |
--- |
1.5 (1) |
--- |
0.1 |
||||||||
Minimum applicable load |
Standard load |
Micro load |
|||||||||||
160 mA at 5 VDC |
1 mA at 5 VDC |
||||||||||||
Inrush current |
NC |
10 A max. |
NO |
10 A max. |
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Approved Standard Ratings
UL/CSA
A300
Voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
120 V |
10 A |
60 A |
6 A |
7,200 |
720 |
TÜV (EN60947-5-1), CCC (GB/T14048.5)
Model |
Applicable category and ratings |
Thermal current |
Indicator |
|||
I |
II |
III |
IV |
|||
1 |
[] |
00 |
AC-14 0.5 A/125 VAC |
5 A |
--- |
|
1 |
[] |
10 |
DC-12 0.5 A/30 VDC |
5 A |
--- |
|
1 |
[] |
20, 21, 22 |
AC-15 2A/250 VAC |
5 A |
--- |
|
1 |
[] |
23, 24 |
L |
AC-15 2A/250 VAC |
5 A |
Neon lamp |
1 |
[] |
23, 24 |
L1 |
DC-12 2A/12 VDC |
5 A |
LED |
1 |
[] |
23, 24 |
L2 |
DC-12 2A/24 VDC |
5 A |
LED |
1 |
[] |
23, 24 |
L3 |
DC-12 2A/48 VDC |
5 A |
LED |
2 |
[] |
00 |
AC-14 0.1A/125 VAC |
0.5 A |
--- |
|
2 |
[] |
10 |
DC-12 0.1A/30 VDC |
0.5 A |
--- |
|
2 |
[] |
20, 21, 22 |
AC-14 0.1A/125 VAC |
0.5 A |
--- |
|
2 |
[] |
23, 24 |
L |
AC-14 0.1A/125 VAC |
0.5 A |
Neon lamp |
2 |
[] |
23, 24 |
L1 |
DC-12 0.1A/12 VDC |
0.5 A |
LED |
2 |
[] |
23, 24 |
L2 |
DC-12 0.1A/24 VDC |
0.5 A |
LED |
2 |
[] |
23, 24 |
L3 |
DC-12 0.1A/48 VDC |
0.5 A |
LED |
Note: 1. []:Actuator variation of item II
2. AC-14 0.5 A/125 VAC means as follows:
3. Applicable category: AC-14
Rated operating current (Ie): 0.5 A
Rated operating voltage (Ue): 125 VAC
Characteristics
Degree of protection |
IP67 |
|
Durability * |
Mechanical |
10,000,000 operations min. |
Electrical |
500,000 operations min. (5 A at 250 VAC, resistive load) |
|
Operating speed |
0.1 mm/sec to 0.5 m/sec |
|
Operating frequency |
Mechanical: 120 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance |
15 mΩ max. (initial value for the built-in switch when tested alone) |
|
Dielectric strength |
Between terminals of same |
1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and |
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) |
|
Rated insulation voltage (Ui) |
250V |
|
Pollution degree (operating environment) |
3 (EN60947-5-1) |
|
Short-circuit protective device (SCPD) |
10 A fuse (type gG or gI, IEC60269 approved) |
|
Conditional short-circuit current |
100 A (EN60947-5-1) |
|
Conventional enclosed thermal current (Ithe) |
5 A (EN60947-5-1) |
|
Protection against electric shock |
Class II (grounding not required with double insulation) |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction |
1,000 m/s2 max. |
Malfunction |
300 m/s2 max. |
|
Ambient operating temperature |
-10°C to +80°C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight |
Approx. 86 g (in case of roller plunger) |
Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
* Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.