Small Sealed Switch

D4E-[]N

Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E

Approved Standards

Agency

Standard

File No.

Approved models

UL

UL508

E76675

D4E-[][]20N Switches only except for Indicator-
 equipped Switches

CSA

CSA C22.2 No. 14

LR45746

D4E-[][]20N Switches only except for Indicator-
 equipped Switches

TÜV Rheinland

EN60947-5-1

R9551015

Ask your OMRON representative for information on
 approved models.

CCC (CQC)

GB/T14048.5

Contact your OMRON
 representative for details.

Ask your OMRON representative for information on
 approved models.

Ratings

Rated voltage

Standard load

Micro load

Non-inductive load (A)

Inductive load (A)

Non-inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

Resistive load

NC

NO

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
 250 VAC

5 (1)
 5 (1)

1.5 (1)
 1.5 (1)

3 (1)
 3 (1)

2 (1)
 1

1 (1)
 0.5

0.1
 ---

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

5 (1)
 5 (1)
 5 (1)
 0.5
 0.25

---
 ---
 ---
 ---
 ---

1.5 (1)
 1.5 (1)
 1.5 (1)
 0.05
 0.03

---
 ---
 ---
 ---
 ---

0.1
 0.1
 0.1
 ---
 ---

Minimum applicable load

Standard load

Micro load

160 mA at 5 VDC

1 mA at 5 VDC















 

Inrush current 

NC 

10 A max.

NO 

10 A max.

Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
           2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
           3. Lamp load has an inrush current of 10 times the steady-state current.
           4. Motor load has an inrush current of 6 times the steady-state current.

Approved Standard Ratings

UL/CSA
 A300

Voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 V
 240 V

10 A

60 A
 30 A

6 A
 3 A

7,200

720

TÜV (EN60947-5-1), CCC (GB/T14048.5)

 image

Model

Applicable category and ratings

Thermal current
 (Ithe)

Indicator

I

II

III

IV

1

[]

00


AC-14 0.5 A/125 VAC

5 A

---

1

[]

10


DC-12 0.5 A/30 VDC

5 A

---

1

[]

20, 21, 22


AC-15 2A/250 VAC
 DC-12 2A/48 VDC

5 A

---

1

[]

23, 24

L

AC-15 2A/250 VAC

5 A

Neon lamp

1

[]

23, 24

L1

DC-12 2A/12 VDC

5 A

LED

1

[]

23, 24

L2

DC-12 2A/24 VDC

5 A

LED

1

[]

23, 24

L3

DC-12 2A/48 VDC

5 A

LED

2

[]

00


AC-14 0.1A/125 VAC

0.5 A

---

2

[]

10


DC-12 0.1A/30 VDC

0.5 A

---

2

[]

20, 21, 22


AC-14 0.1A/125 VAC
 DC-12 0.1A/48 VDC

0.5 A

---

2

[]

23, 24

L

AC-14 0.1A/125 VAC

0.5 A

Neon lamp

2

[]

23, 24

L1

DC-12 0.1A/12 VDC

0.5 A

LED

2

[]

23, 24

L2

DC-12 0.1A/24 VDC

0.5 A

LED

2

[]

23, 24

L3

DC-12 0.1A/48 VDC

0.5 A

LED

Note: 1. []:Actuator variation of item II
            2. AC-14 0.5 A/125 VAC means as follows:
            3. Applicable category: AC-14
                 Rated operating current (Ie): 0.5 A
                 Rated operating voltage (Ue): 125 VAC

Characteristics

Degree of protection

IP67

Durability *

Mechanical

10,000,000 operations min.

Electrical

500,000 operations min. (5 A at 250 VAC, resistive load)
 5,000,000 operations min. (10 mA at 24 VDC, resistive load)

Operating speed

0.1 mm/sec to 0.5 m/sec

Operating frequency

Mechanical: 120 operations/min
 Electrical: 30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

15 mΩ max. (initial value for the built-in switch when tested alone)

Dielectric strength

Between terminals of same
 polarity

1,000 VAC, 50/60 Hz for 1 min

Between each terminal and
 non-current-carrying metal
 part

1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

250V

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse (type gG or gI, IEC60269 approved)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (Ithe)

5 A (EN60947-5-1)

Protection against electric shock

Class II (grounding not required with double insulation)

Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Destruction

1,000 m/s2 max.

Malfunction

300 m/s2 max.

Ambient operating temperature

-10°C to +80°C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight

Approx. 86 g (in case of roller plunger)

Note: 1. The above values are initial values.                    
           2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
 * Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.