Enclosed Switch
D4MC
Economical, High Utility Enclosed Switch
Approved Standards
Agency |
Standard |
File No. |
UL * |
UL508, CSA C22.2 No.14 |
E76675 |
CCC(CQC) |
GB/T14048.5 |
Contact your OMRON representative for details. |
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
|
|||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|
||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
||
125 VAC |
10 |
3 |
1.5 |
10 |
5 |
2.5 |
||||
8 VDC |
10 |
3 |
1.5 |
6 |
5 |
2.5 |
||||
Inrush current |
NC |
30 A max. |
|
|||||||
NO |
15 A max. |
|
||||||||
|
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Approved Standard Ratings
UL/CSA
A300
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
120 VAC |
10A |
60 |
6 |
7,200 |
720 |
240 VAC |
30 |
3 |
EN60947-5-1
CCC (GB/T14048.5)
Applicable category and ratings |
AC-12 10 A/250 VAC |
Characteristics
Degree of protection |
IP67 |
|
Durability |
Mechanical |
10,000,000 operations min. |
Electrical |
500,000 operations min. |
|
Operating speed |
0.05 mm/s to 0.5 m/s *1 |
|
Operating |
Mechanical |
120 operations/min |
Electrical |
20 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 M Ω min. (at 500 VDC) |
|
Contact resistance |
15 m Ω max. (initial value for the built-in switch when tested alone) |
|
Dielectric |
Between terminals of the same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- |
2,000 VAC, 50/60 Hz for 1 min |
|
Rated insulation voltage (Ui) |
1,000 VAC |
|
Pollution degree (operating environment) |
3 (IEC947-5-1) |
|
Protection against electric shock |
Class II |
|
PTI (tracking characteristics) |
175 |
|
Switch category |
D (IEC335) |
|
Rated operating current (Ie) |
10 A |
|
Rated operating voltage (Ue) |
250 VAC |
|
Vibration |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock |
Destruction |
1,000 m/s2 min. |
Malfunction |
100 m/s2 min. *1 *2 |
|
Ambient operating temperature |
- 10 ° C to +80 ° C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight |
Approx. 71 g (in case of panel mount plunger) |
1. Only for models with plungers. (Contact your OMRON representative for information on other models.)
2. Less than 1 ms under a free state at the operating limits.