Safety Laser Scanners
OS32C
Compact (104.5 mm), lightweight (1.3 kg) and easy-to-install Safety Laser Scanner
Rating/Performance
Sensor Type |
Type 3 Safety Laser Scanner |
|
Performance Level (PL)/ |
PLd/Safety Category 3 (ISO 13849-1) |
|
Functional Safety of |
SIL 2, PFHD = 8.3 × 10-8(IEC61508) |
|
Detection Capability |
Configurable via the configuration tool; Non-transparent with a diameter of 30, 40, 50, 70mm |
|
Monitoring Zone |
Monitoring Zone Set Count: (Safety Zone + 2 Warning Zones) x 70 sets |
|
Operating |
OS32C-[][][] |
Safety Zone: 1.75 m (min. obj. resolution of 30 mm) |
OS32C-[][][]-4M |
Safety Zone: 1.75 m (min. object resolution of 30mm) |
|
Maximum Measurement Error |
100 mm (at range of 3 m or less) *1 |
|
Detection Angle |
270° |
|
Angular Resolution |
0.4° |
|
Laser Beam Diameter |
6 mm at optics cover, 14 mm (typical) at 3 m. |
|
Laser Scan Plane Height |
67mm from the bottom of the scanner |
|
Response Time |
Response time from ON to OFF: |
|
Zone Switching Time |
20 to 320 ms |
|
Line Voltage |
24 VDC +25%/-30% (ripple p-p 2.5 V max.) *2 |
|
Power Consumption |
Normal operation: 5 W max. *3 |
|
Emission Source (Wavelength) |
Infrared Laser Diode (905 nm) |
|
Laser Protection Class |
Class 1: IEC/EN60825-1 |
|
Safety Output (OSSD) |
PNP transistor x 2, load current of 250 mA max., residual voltage of 2 V max., |
|
Auxiliary Output (Non-Safety) |
NPN/PNP transistor x 1, load current of 100 mA max., |
|
Warning Output (Non-Safety) |
NPN/PNP transistor x 1, load current of 100 mA max., |
|
Operation Mode |
Auto Start, Start Interlock, Start/Restart Interlock |
|
Input |
External Device |
ON: 0 V short (input current of 50 mA), OFF: Open |
Start |
ON: 0 V short (input current of 20 mA), OFF: Open |
|
Zone Select |
ON: 24 V short (input current of 5 mA), OFF: Open |
|
Stand-by |
ON: 24 V short (input current of 5 mA max.), OFF: Open |
|
Connection Type |
Power Cable: 18-pin mini-connector (pigtail) |
|
Connection with PC |
Communication: Ethernet *6 |
|
Indicators |
RUN indicator: Green, STOP indicator: Red, Interlock Indicator: Yellow, |
|
Protective Circuit |
Protection against output load short and reverse power connection |
|
Ambient Temperature |
Operation: -10 to 50 °C, Storage: -25 to 70 °C |
|
Ambient Humidity |
Operation & Storage: 95% RH max., non-condensing |
|
Ambient Operation |
Incandescent lamp: Illumination on receiving surface 1500 lx max. |
|
Insulation Resistance |
20 MΩ or higher (500 VDC) |
|
Dielectric Withstand Voltage |
350VDC, 1 minute |
|
Enclosure Rating |
IP65 (IEC60529) |
|
Enclosure |
Sensor head: Die-cast aluminum, optical cover: Polycarbonate, I/O block: Die-cast aluminum |
|
Dimensions (WxHxD) |
133.0 x 104.5 x 142.7 mm (except cable) |
|
Impact Resistance |
98 m/s2 1,000 times for each of X, Y, and Z directions (IEC60068-2-29) |
|
Vibration |
10 to 55 Hz double-amplitude of 0.7 mm, 20 sweepings for X, Y, and Z directions (IEC60068-2-6) |
|
Weight (Main Unit only) |
1.3 kg |
|
Power Cable |
Up to 30 m |
|
Communication Cable |
Up to 100 m for 100BASE-TX cable *9 |
|
Approvals |
Certificated by: TÜV Rheinland, UL |
*1. An additional measurement error may need to be added due to reflective backgrounds.
*2. For power source specification, refer to “Safety Precautions” on Catalog.
*3. Rated current of OS32C is 1.025 A max. (OS32C 210 mA + OSSD A load + OSSD B load + Auxiliary output load + Warning output load + Functional Inputs). Where functional inputs are: EDM input ... 50 mA Start input ... 20 mA Standby input ... 5 mA Zone X input ... 5 mA x 8 (eight zone set select inputs)
*4. Output voltage is Input voltage - 2.0 VDC.
*5. Total consumption current of 2 OSSDs, auxiliary output, and warning output must not exceed 700 mA.
*6. An ethernet cable with an M12, 4-pin connector is required.
*7. Output polarity (NPN/PNP) is configurable via the configuration tool.
*8. Pollution Tolerance mode will add 6 ms to each scan time.
*9. Omron only supplies up to a 15 m Ethernet cable. For longer lengths a connection to a network switch/router is needed.