Safety-door Hinge Switch
D4NH
Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certified Standards
Certification body |
Standard |
File No. |
TÜV SÜD |
EN60947-5-1 (certified direct opening) |
Consult your OMRON representative for details. |
UL * |
UL508, CSA C22.2 No.14 |
E76675 |
CCC (CQC) |
GB/T 14048.5 |
Consult your OMRON representative for details. |
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Certified Standard Ratings
TÜV (EN60947-5-1)
Utilization category |
AC-15 |
DC-13 |
Rated operating current (Ie) |
3 A |
0.27 A |
Rated operating voltage (Ue) |
240 V |
250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
120 VAC |
10 A |
60 |
6 |
7,200 |
720 |
240 VAC |
30 |
3 |
Q300
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (VA) |
||
Make |
Break |
Make |
Break |
||
125 VDC |
2.5 A |
0.55 |
0.55 |
69 |
69 |
250 VDC |
0.27 |
0.27 |
Characteristics
Interlock type |
Type 1 (EN ISO 14119) |
|
Coding level |
Uncoded (EN ISO 14119) |
|
Degree of protection *1 |
IP67 (EN60947-5-1) |
|
Durability *2 |
Mechanical |
1,000,000 operations min. |
Electrical |
500,000 operations min. (3 A resistive load at 250 VAC) *3 |
|
Operating speed |
2 to 360°/s |
|
Operating frequency |
30 operations/minute max. |
|
Direct opening force *4 |
1 N·m min. |
|
Direct opening travel *4 |
18° min. |
|
Contact resistance |
25 mΩ max. |
|
Minimum applicable load *5 |
1 mA resistive load at 5 VDC (N-level reference value) |
|
Rated insulation voltage (Ui) |
300 V |
|
Rated frequency |
50/60 Hz |
|
Protection against electric shock |
Class II (double insulation) |
|
Pollution degree (operating environment) |
3 (EN60947-5-1) |
|
Impulse withstand |
Between terminals of same |
2.5 kV |
Between terminals of different |
4 kV |
|
Between each terminal and |
6 kV |
|
Insulation resistance |
100 MΩ min. |
|
Contact gap |
2 × 2 mm min. |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance |
Destruction |
1,000 m/s2 min. |
Malfunction |
300 m/s2 min. |
|
Conditional short-circuit current |
100 A (EN60947-5-1) |
|
Conventional free air thermal current (Ith) |
10 A (EN60947-5-1) |
|
Ambient operating temperature |
-30 to 70°C (with no icing) |
|
Ambient operating humidity |
95% max. |
|
Weight |
Approx. 87 g (D4NH-1AAS) |
Note: 1. The above values are initial values.
2. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NH in places where foreign material such as dust, dirt, oil, water, or chemicals may enter through the head. Otherwise, accelerated wear, Switch damage, or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. Be sure to provide this amount to ensure safety in operation.
*5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.