G5 Series Linear Motor/Servo Drives with built-in EtherCAT Communications Linear Motor Type

R88L-EC, R88D-KN[]-ECT-L

Linear Motor for Higher-speed and Higher-precision

AC Servo Drives
General Specifications
Item
Specifications
Ambient operating temperature and humidity
0 to 55 °C, 20% to 85% max. (with no condensation)
Storage ambient temperature and humidity
-20 to 65°C, 20% to 85% max. (with no condensation)
Operating and storage atmosphere
No corrosive gases
Vibration resistance
10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be
run continuously at the resonance point)
Insulation resistance
Between power supply terminals/power terminals and FG terminal:
0.5 MΩ min. (at 500 VDC)
Dielectric strength
Between power supply/power terminals and FG terminal: 1,500 VAC
for 1 min at 50/60 Hz
Protective structure
Built into panel
EU Directives
and

UK legislation*
EMC
EN 55011, EN 61000-6-2, EN 61800-3
Low Voltage
EN 61800-5-1
Machinery
EN954-1 (Cat.3), EN ISO13849-1 (Cat.3) (PLc, d), ISO13849-1 (Cat.3)
(
PLc, d), EN61508 (SIL2), EN62061 (SIL2), EN61800-5-2 (STO),
IEC61326-3-1 (SIL 2)
UL standards
UL 508C
CSA standards
CSA C22.2 No.14
Korean Radio Regulations (KC)
Certified
* The certification from third party is issued in combination with the revolution type motor. The conformance as the whole system should be checked by machine builder.
Note: 1.
The above items reflect individual evaluation testing. The results may differ under compound conditions.
Note: 2.
Always disconnect all connections to the Servo Drive before you perform insulation resistance tests on it. If you perform an insulation resistance test while the Servo Drive is connected, the Servo Drive may be damaged. Never perform dielectric strength tests on the Servo Drive. Failure to follow this precaution may result in damaging internal elements.
Note: 3. Some Servo Drive parts will require maintenance. For details, refer to the G5 series USER'S MANUAL. Confirm the Manual No. that is listed in Related Manuals.

Note: 4. Vibration, unstable movement, or
accoustic noise may occur by an exogenous noise. In such case, please reduce incoming noise as referred in G5 series user's manuals.
Characteristics
100-VAC Input Models
for Single-phase input type
Item
R88D-KN01L-
ECT-L
R88D-KN02L-
ECT-L
R88D-KN04L-
ECT-L
Input
power

supply
Main
circuit
Power supply capacity
0.4 KVA
0.5 KVA
0.9 KVA
Power supply voltage
Single-phase 100 to 120 VAC (85 to 132 VAC) 50/60 Hz
Rated current
2.6 A
4.3 A
7.6 A
Heat value *1
16.6 W
21 W
25 W
Control
circuit
Power supply voltage
Single-phase 100 to 120 VAC (85 to 132 VAC) 50/60 Hz
Heat value *1
4 W
4 W
4 W
Mass
Approx. 0.8 kg
Approx. 1.0 kg
Approx. 1.6 kg
Maximum
motor

capacity
Motor Rated Rms Current
1.7 Arms
2.5 Arms
4.6 Arms
Maximum current of motor
5.1 Arms
7.5 Arms
13.8 Arms
*1. The heat value is given for rated operation.
200-VAC Input Models
for Single-phase/Three-phase input type
Item
R88D-
KN01H-

ECT-L
R88D-
KN02H-

ECT-L
R88D-
KN04H-

ECT-L
R88D-
KN08H-

ECT-L
R88D-
KN10H-

ECT-L
R88D-
KN15H-

ECT-L
Input
power

supply
Main
circuit
Power supply capacity
0.5 KVA
0.5 KVA
0.9 KVA
1.3 KVA
1.8 KVA
2.3 KVA
Power supply voltage
Single-phase or 3-phase 200 to 240 VAC (170 to 264 VAC) 50/60 Hz
Rated current
1.6/0.9 A
*1
2.4/1.3 A
*1
4.1/2.4 A
*1
6.6/3.6 A
*1
9.1/5.2 A
*1
14.2/8.1 A
*1
Heat value *2
14.3/
13.7 W *1
23/19 W
*1
33/24 W
*1
30/35.5 W
*1
57/49 W
*1
104/93 W
*1
Control
circuit
Power supply voltage
Single-phase 200 to 240 VAC (170 to 264 VAC) 50/60 Hz
Heat value *2
4 W
4 W
4 W
4 W
7 W
7 W
Mass
Approx.
0.8 kg
Approx.
0.8 kg
Approx.
1.0 kg
Approx.
1.6 kg
Approx.
1.8 kg
Approx.
1.8 kg
Maximum
motor

capacity
Rated effective current of
motor
1.2 Arms
1.6 Arms
2.6 Arms
4.1 Arms
5.9 Arms
9.4 Arms
Maximum current of motor
3.6 Arms
4.8 Arms
7.8 Arms
12.3 Arms
16.9 Arms
28.2 Arms
*1. The first value is for single-phase input power and the second value is for 3-phase input power.
*2. The heat value is given for rated operation.
400-VAC Input Models
for Three-phase input type
Item
R88D-
KN06F-

ECT-L
R88D-
KN10F-

ECT-L
R88D-
KN15F-

ECT-L
R88D-
KN20F-

ECT-L
R88D-
KN30F-

ECT-L
Input
power

supply
Main
circuit
Power supply capacity
1.2 KVA
1.8 KVA
2.3 KVA
3.8 KVA
4.5 KVA
Power supply voltage
3-phase 380 to 480 VAC (323 to 528 VAC) 50/60 Hz
Rated current
2.1 A
2.8 A
3.9 A
5.9 A
7.6 A
Heat value *1
32.2 W
48 W
49 W
65 W
108 W
Control
circuit
Power supply voltage
24 VDC (20.4 to 27.6 VAC)
Heat value *1
7 W
7 W
7W
10 W
13 W
Mass
Approx.
1.9 kg
Approx.
1.9 kg
Approx.
1.9 kg
Approx.
2.7 kg
Approx.
4.7 kg
Maximum
motor

capacity
Rated effective current of
motor
1.5 Arms
2.9 Arms
4.7 Arms
6.7 Arms
9.4 Arms
Maximum current of motor
4.5 Arms
8.7 Arms
14.1 Arms
19.7 Arms
28.2 Arms
*1. The heat value is given for rated operation.
EtherCAT Communications Specifications
Item
Specification
Communications standard
IEC 61158 Type 12, IEC 61800-7 CiA 402 Drive Profile
Physical layer
100BASE-TX (IEEE802.3)
Connectors
RJ45 × 2 (shielded)
ECAT IN:
EtherCAT input
ECAT OUT:
EtherCAT output
Communications media
Ethernet Category 5 (100BASE-TX) or higher (twisted-pair cable with double,
aluminum tape and braided shielding) is recommended.
Communications distance
Distance between nodes: 100 m max.
Process data
Fixed PDO mapping
Mailbox (CoE)
Emergency messages, SDO requests, SDO responses, and SDO information
Distributed clock (DC)
Synchronization in DC mode.
DC cycle: 250
μs, 500 μs, 1 ms, 2 ms, 4 ms
LED indicators
L/A IN (Link/Activity IN) × 1
L/A OUT (Link/Activity OUT) × 1

RUN × 1

ERR × 1
CiA402 Drive Profile
Cyclic synchronous position mode
Cyclic synchronous velocity mode

Cyclic synchronous torque mode

Profile position mode

Homing mode

Touch probe function (Latch function)

Torque limit function
Linear Motor
General Specifications
Iron-core Linear Motors
Item
Description
Operating ambient temperature humidity
0 to 40°C, 20% to 80% (with no condensation)
Storage ambient temperature and humidity
- 20 to +65°C, 85% max. (with no condensation)
Operating and storage atmosphere
No corrosive gases
Vibration resistance *
Acceleration of 49 m/s2 max. in X, Y, and Z directions
Impact resistance
Acceleration of 98 m/s2 max. 3 times each in X, Y, and Z directions
Insulation resistance
Between power terminal and FG terminal: 10 MΩ min. (at 500 VDC)
Dielectric strength
Between power terminal and FG terminal: 2,750 VDC for 1 s
Between power terminal and sensor: 2,750 VDC for 1 s
Protective structure
IP00
Maximum coil temperature (Motor Coil Unit)
130°C
Maximum magnet temperature
(Magnet Track)
70°C
Insulation class
Class B
Cooling method
Self-cooling
International
standard
EU
Directives
Low voltage
EN60034-1
* The amplitude may be increased by machine resonance. As a guideline, do not exceed 80% of the specified value.
Ironless Linear Motors
Item
Description
Operating ambient temperature humidity
0 to 40°C, 20% to 80% (with no condensation)
Storage ambient temperature and humidity
- 20 to +65°C, 85% max. (with no condensation)
Operating and storage atmosphere
No corrosive gases
Vibration resistance *
Acceleration of 49 m/s2 max. in X, Y, and Z directions
Impact resistance
Acceleration of 98 m/s2 max. 3 times each in X, Y, and Z directions
Insulation resistance
Between power terminal and FG terminal: 10 MΩ min. (at 500 VDC)
Dielectric strength
Between power terminal and FG terminal: 2,250 VDC for 1 s
Between power terminal and sensor: 2,250 VDC for 1 s
Protective structure
IP00
Maximum coil temperature (Motor Coil Unit)
110°C
Maximum magnet temperature
(Magnet Track)
70°C
Insulation class
Class B
Cooling method
Self-cooling
International
standard
EU
Directives
Low voltage
EN60034-1
* The amplitude may be increased by machine resonance. As a guideline, do not exceed 80% of the specified value.
Characteristics
Iron-core Linear Motors
Item
Unit
R88L-EC-
FW-
0303-

ANPC
FW-
0306-

ANPC
FW-
0606-

ANPC
FW-
0609-

ANPC
FW-
0612-

ANPC
FW-
1112-

ANPC
FW-
1115-

ANPC
Maximum speed
(100 VAC)
m/s
2.5
2.5
2
-
-
-
-
Maximum speed
(200 VAC)
m/s
5
5
4
4
4
2
2
Maximum speed
(400 VAC)
m/s
10
10
8
8
8
4
4
Continuous force *1
N
48
96
160
240
320
608
760
Momentary maximum
force *2
N
105
210
400
600
800
1,600
2,000
Continuous current *2
Arms
1.24
2.4
3.4
5.2
6.9
6.5
8.2
Momentary maximum
current *1
Arms
3.1
6.1
10
15
20
20
25
Motor force constant
N/Arms
39.7
39.7
46.5
46.5
46.5
93.0
93.0
Back electromotive
force
Vs/m
13.2
13.2
15.5
15.5
15.5
31
31
Motor constant
N/√W
9.75
13.78
19.49
23.87
27.57
41.47
46.37
Phase resistance
Ω
5.34
2.68
1.83
1.23
0.92
1.6
1.29
Phase inductance
mH
34.7
17.4
13.7
9.2
6.9
12.8
10.3
Electrical time
constant
ms
6.5
6.5
7.5
7.5
7.5
8
8
Maximum continuous
power consumption
W
32
63
88
131
175
279
349
Thermal resistance
K/W
2.20
1.10
0.78
0.52
0.39
0.23
0.18
Thermal time
constant
s
110
110
124
124
124
126
126
Magnetic attractive
force
N
300
500
1,020
1,420
1,820
3,640
4,440
Magnetic pole pitch
mm
24
24
24
24
24
24
24
Mass (except cables)
kg
0.48
0.78
1.31
1.84
2.37
4.45
5.45
Cooling plate
dimensions
mm
238 ×
220 × 10
238 ×
220 × 10
250 ×
287 × 12
250 ×
287 × 12
250 ×
287 × 12
371 ×
330 × 14
371 ×
330 × 14
Application Servo Drives
(R88D-[]-ECT-L)
KN01L/
KN02H/
KN06F
KN02L/
KN04H/
KN10F
KN04L/
KN08H/
KN15F
KN10H/
KN20F
KN15H/
KN30F
KN15H/
KN30F
KN15H/
KN30F
Magnet Trac (R88L-EC-)
FM-03096-A/
FM-03144-A/

FM-03384-A
FM-06192-A/FM-06288-A
FM-11192-A/
FM-11288-A
Magnet Trac Unit
Length
mm
96/144/384
192/288
192/288
*1. This shows a value measured when the Motor Coil Unit is at 100°C and the Magnet Trac is at 25°C. The coil unit is mounted in the center of an aluminum moving table (heat sink) which has its size larger than indicated in table as cooling condition.
*2. The Motor Coil Unit is subjected to a temperature rise of 6 K/s.
Ironless Linear Motors
Item
Unit
R88L-EC-
GW-0303-ANPS
GW-0306-ANPS
GW-0309-ANPS
Maximum speed (100VAC)
m/s
8
-
8
8
Maximum speed (200VAC)
m/s
-
16
16
16
Continuous force *1
N
26.5
53
80
Momentary maximum force *2
N
100
96
200
300
Continuous current *2
Arms
1.33
2.66
4.0
Momentary maximum current *1
Arms
5.0
4.8
10.0
15.0
Motor force constant
N/Arms
19.9
19.9
19.9
Back electromotive force
Vs/m
6.6
6.6
6.6
Motor constant
N/√W
4.90
6.93
8.43
Phase resistance
Ω
5.5
2.8
1.8
Phase inductance
mH
1.8
0.9
0.6
Electrical time constant
ms
0.35
0.35
0.35
Maximum continuous power
consumption
W
47
95
142
Thermal resistance
K/W
2.1
1.06
0.71
Thermal time constant
s
36
36
36
Magnetic attractive force
N
0
0
0
Magnetic pole pitch
mm
30
30
30
Mass (except cables)
kg
0.084
0.162
0.24
Application Servo Drives (R88D-[]-ECT-L)
KN01L
KN02H
KN04L/KN08H
KN10H
Magnet Trac (R88L-EC-)
GM-03090-A/GM-03120-A/GM-03390-A
Magnet Trac Unit Length
mm
90/120/390
Item
Unit
R88L-EC-
GW-
0503-

ANPS
GW-
0506-

ANPS
GW-
0509-

ANPS
GW-
0703-

ANPS
GW-
0706-

ANPS
GW-
0709-

ANPS
Maximum speed (100VAC)
m/s
2.2
2.2
2.2
1.2
1.2
-
Maximum speed (200VAC)
m/s
4.4
4.4
4.4
2.4
2.4
2.4
Continuous force *1
N
58
117
175
117
232
348
Momentary maximum force *2
N
240
480
720
552
1110
1730
Continuous current *2
Arms
0.87
1.76
2.60
0.94
1.87
2.81
Momentary maximum current *1
Arms
3.50
7.1
10.6
4.5
9.0
14
Motor force constant
N/Arms
68.0
68.0
68.0
124.0
124.0
124.0
Back electromotive force
Vs/m
22.7
22.7
22.7
41.3
41.3
41.3
Motor constant
N/√W
9.85
13.96
17.03
17.97
25.44
31.14
Phase resistance
Ω
15.9
8.0
5.3
15.8
7.9
5.3
Phase inductance
mH
13
6.5
4.2
28.0
14.0
9.0
Electrical time constant
ms
0.8
0.8
0.8
1.8
1.8
1.8
Maximum continuous power
consumption
W
67
134
200
82
165
247
Thermal resistance
K/W
1.70
0.85
0.65
1.56
1.04
0.52
Thermal time constant
s
72
72
72
96
96
96
Magnetic attractive force
N
0
0
0
0
0
0
Magnetic pole pitch
mm
42
42
42
57
57
57
Mass (except cables)
kg
0.25
0.47
0.69
0.55
0.95
1.35
Application Servo Drives (R88D-[]-ECT-L)
KN01L/
KN01H
KN02L/
KN04H
KN04L/
KN08H
KN02L/
KN04H
KN04L/
KN08H
KN10H
Magnet Trac (R88L-EC-)
GM-05126-A/GM-05168-A/
GM-05210-A/GM-05546-A
GM-07114-A/GM-07171-A/
GM-07456-A
Magnet Trac Unit Length
mm
126/168/210/546
114/171/456
*1. This shows a value measured when the Motor Coil Unit is at 100°C and the Magnet Trac is at 25°C.
*2. The Motor Coil Unit is subjected to a temperature rise of 40 K/s.