Liquid Analysis
Products List
Aluminum analyzer Liquiline System CA80AL
Colorimetric system for drinking water and wastewater monitoring and optimization of process control
Predecessor: Stamolys CA71AL
Measurement range: 15 to 1000 µg/l Al, 15 to 1000 µg/l with dilution function to maximum 300 to 20 000 µg/l Al
Process temperature: 4 … 40 °C (39.2 … 104 °F)
Process pressure: at atmospheric pressure, < 0.2 bar
Iron analyzer Liquiline System CA80FE
Colorimetric system for monitoring of drinking water, mineral water and process water
Predecessor: Stamolys CA71FE
Measurement range: 0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l FeProcess temperature: 4 to 40 °C (39.2 to 104 °F)
Process pressure: At atmospheric pressure, < 0.2 bar
Nitrite analyzer Liquiline System CA80NO
Colorimetric system for monitoring of drinking water, mineral water or raw water for food production
Predecessor: Stamolys CA71NO
Measurement range: 10 to 500 µg/l NO2-N
0.2 to 3.0 mg/l NO2-N
0.1 to 1.0 mg/l NO2-N
0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-NProcess temperature: 4 to 40 °C (39 to 104 °F)
Process pressure: At atmospheric pressure, < 0.2 bar absolute
TP analyzer Liquiline System CA80TP
Total phosphorus analyzer for environmental monitoring, industrial and municipal wastewater
Predecessor: SPECTRON TP CA72TP
Measurement range: 0 to 2 mg/l
0.05 to 10 mg/l
0.5 to 50 mg/lProcess temperature: 4 to 40 °C (39.2 to 104 °F)
Process pressure: At atmospheric pressure, < 0.2 bar
Flow assembly for chlorine dioxide sensors Flowfit CCA151
Simple assembly for drinking and process water applications
Successor: Flowfit CYA27
Process temperature: Max. 60 °C (Max. 140 °F)
Process pressure: Max. 4 bar relative(Max. 58 psi relative)
Analog free chlorine sensor CCS51
Sensor for drinking water, pool and process water as well as utilities in all industries
Predecessor: Chlorine CCS140, Trace Chlorine CCS141
Measurement range: Trace: 0 to 5 mg/l HOCl, Standard: 0 to 20 mg/l HOCl
Process temperature: +0 to 55 °C (32 to 130°F), non-freezing
Process pressure: 1 bar (14.5 psi)
Measuring method: – Closed, membrane covered measuring cell
– Reduction of free chlorine at the cathode
Digital ozone sensor Memosens CCS58D
Memosens sensor for drinking water, wastewater and process water in all industries
Measurement range: 0 to 2 mg/l
Process temperature: +0 to 45 °C (32 to 110 °F), non freezing
Process pressure: 1 bar (14.5 psi), 2 bar (29 psi) absolute
Measuring method: – closed 2 electrode system
– conversion of ozone into a signal current in nA
– signal current is proportional to the concentration of ozone
– the measurement is not pH dependent
Conductivity compact device Smartec CLD134
Toroidal conductivity measuring system for hygienic and sterile applications
Predecessor: CLD130, CLS51
Measurement range: 100 µS/cm to 2000 mS/cm, Cell constant k : 6.3 1/cm
Process temperature: Max. 125 °C (max. 257 °F)
For sterilization: up to 150 °C for max. 60 min (up to 302 °F for max. 60 min)Process pressure: 12 bar abs up to 90 °C
(174 psi abs up to 194 °F)
Digital conductivity sensor Indumax CLS54D
Memosens toroidal conductivity sensor for hygienic and sterile applications
Measurement range: 100 µS/cm to 2000 mS/cm, Cell constant k: 6.3 1/cm
Process temperature: -10 °C to 125 °C (14 °F to 257 °F)
Sterilization: 150 °C at 6 bar abs for max. 60 min (302 °F at 87 psi abs for max. 60 min)Process pressure: 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)
9 bar at 125 °C (130.5 psi abs at 257 °F)
Digital oxygen sensor Oxymax COS22D
Memosens amperometric oxygen sensor for standard, hygienic and sterile applications
Predecessor: Oxymax COS21D, Oxymax W COS71
Successor: Memosens COS22E
Measurement range: 0.001 to 20 mg/l, 0 to 200 %SAT, 0 to 400 hPa
Process temperature: -5 to 135 °C (23 to 275 °F)
Process pressure: 1 to 12 bar abs (14.5 to 174 psi)
Digital oxygen sensor Oxymax COS51D
Memosens amperometric oxygen sensor for water, wastewater and utilities
Predecessor: Oxymax W COS31
Successor: Memosens COS51E
Measurement range: 0.01 to 100 mg/l, 0.00 to 1000 %SAT, 0 to 2000 hPa
Process temperature: -5 to 50 °C (20 to 120 °F)
Process pressure: max. 10 bar (max. 145 psi)
Zero-point gel COY8
Digital pH sensor Ceragel CPS71D
Memosens glass electrode for the chemical and life sciences industries
Successor: Memosens CPS61E, Memosens CPS71E
Measurement range: pH 0 to 14
Process temperature: 0 to 140 °C (32 to 284 °F)
Process pressure: 1 to 14 bar (15 to 203 psi)
Suspended solids sensor Turbimax CUS51D
Memosens sensor for suspended solids and turbidity measurement in water, wastewater and utilities
Predecessor: Turbimax W CUS41, Turbimax CUS65
Measurement range: For formazin: 0 to 4000 FNU, Display range up to 9999 FNU, For sludge: 0 to 300 g/L, The achievable measuring range depends very much on the media
Process temperature: Process temperature: -5 to 50 °C (23 to 122 °F)
Ambient temperature: -20 to 60 °C (-4 to 140 °F)
Immersion assembly Flexdip CYA112
Modular assembly for water, wastewater and utilities
Predecessor: CPA530, CPA610, Dipfit W CYA611
Process temperature: 0 to 60 °C (32 to 140 °F)
Modular holder system Flexdip CYH112
Holder for in-situ measurement in water, wastewater and utilities
Predecessor: Universal CYH101
Process temperature: -20 to 60 °C (-4 to 140 °F)
Digital pH sensor Orbipac CPF81D
Memosens compact electrode for wastewater, primaries and metal industries
Successor: Memosens CPF81E
Measurement range: pH 0 to 14
Process temperature: Version LH: 0 to 110 °C (32 to 230 °F)
Version NN: 0 to 80 °C (32 to 170 °F)Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi at 176 °F)
Digital ORP sensor Orbipac CPF82D
Memosens compact electrode for wastewater, primaries and metal
Successor: Memosens CPF82E
Measurement range: -1500mV to +1500mV
Process temperature: 0 to 80 °C (32 to 170 °F)
Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi abs at 176 °F)
Digital pH sensor Orbisint CPS11D
Memosens glass electrode for standard applications
Successor: Memosens CPS11E
Measurement range: pH 0 to 14
Process temperature: 0 to 135 °C (32 to 275 °F)
Process pressure: 1 to 17 bar (15 to 246 psi)
Digital ORP sensor Orbisint CPS12D
Memosens glass electrode for standard applications
Successor: Memosens CPS12E
Measurement range: -1500 mV to +1500 mV
Process temperature: -15 to 135 °C (5 to 275 °F)
Process pressure: 0 to 16 bar (0 to 232 psi)
Digital combined pH/ORP sensor Memosens CPS16D
Memosens glass electrode for standard applications
Successor: Memosens CPS16E
Process temperature: 0 to 135 °C (32 to 275 °F)
Process pressure: 1 to 17 bar (15 to 246 psi)
Digital pH sensor Memosens CPS31D
Memosens glass electrode for application in drinking water and swimming pools
Successor: Memosens CPS31E
Measurement range: pH 1 to 12
Process temperature: 0 to 80 °C (32 to 176 °F)
Process pressure: 1 to 4 bar (15 to 60 psi)
Digital non-glass pH sensor Ceramax CPS341D
Memosens enamel electrode for food and life sciences industries
Measurement range: pH -2 to 14
Process temperature: 0 to 140 °C (32 to 280 °F)
Process pressure: 0 to 7 bar abs (0 to 101.5 psi)
Digital pH sensor Ceraliquid CPS41D
Memosens glass electrode for the chemical and life sciences industries
Successor: Memosens CPS41E
Measurement range; pH 0 to 14
Process temperature: 0 to 135 °C (32 to 275 °F)
Process pressure: 1 to 11 bar abs (15 to 160 psi)
Digital ORP sensor Ceraliquid CPS42D
Memosens glass electrode for applications with fast-changing medium compositions or low conductivity
Successor: Memosens CPS42E
Measurement range: -1500 mV – +1500 mV
Process temperature: -15°C – 130°C
Process pressure: max. 8bar
Digital ORP sensor Ceragel CPS72D
Memosens glass electrode for the chemical and life sciences industries
Successor: Memosens CPS72E
Measurement range: -1500mV – +1500mV
Process temperature: -15°C – 140°C
Process pressure: max. 16bar
Digital combined pH/ORP sensor Memosens CPS76D
Memosens glass electrode for the chemical and life sciences industries
Successor: Memosens CPS76E
Measurement rangeL: pH 0-14
Process temperature: -15°C … 140°C (5°F – 284°F)
Process pressure: max. 13 bar (188 psi)depends on selected version
Digital pH sensor Orbipore CPS91D
Memosens glass sensor for heavily polluted media in chemical processes, paper or paint production
Successor: Memosens CPS91E
Measurement range: 0 to 14 pH
Process temperature: 0 to 110 °C (32 to 230 °F)
Process pressure: 1 to 14 bar (15 to 203 psi)
Digital ORP sensor Orbipore CPS92D
Memosens glass sensor for heavily polluted media in chemical processes, paper or paint production
Successor: Memosens CPS92E
Measurement range: -1500 mV – +1500 mV
Process temperature: max. 110°C (230°F)
Process pressure: max. 13bar (189psi)
Digital combined pH/ORP sensor Memosens CPS96D
Memosens glass sensor for heavily polluted media in chemical processes, paper or paint production
Successor: Memosens CPS96E
Measurement range: pH 0-14
Process temperature: max. 110°C (230°F)
Process pressure: max. 10 bar (145 psi)