Sodium analyzer CA76NA

Potentiometric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers

  • Measurement range: 0.1 to 9999 µg/l (ppb) Na

  • Process temperature: 10 to 40 °C (50 to 104 °F)

  • Process pressure: 1 to 5 bar (abs) 14.5 to 72.5 psi

Low-range TOC analyzer CA78

Precise online TOC monitoring in power plants and semiconductor production

  • Measurement range: 0.5 to 1 000 μg/l (ppb)
  • Process temperature: < 50 °C (122 °F)
  • Process pressure: max. 0.5 bar (7.25 psi)
  • Measuring method:TOC determination by UV digestion and measurement of the differential conductivity

Low-range TOC analyzer CA79

Precise online TOC monitoring in the life sciences industry

  • Measurement range: 0.5 to 1 000 μg/l (ppb)
  • Process temperature: < 50 °C (122 °F)
  • Process pressure: max. 0.5 bar (7.25 psi)
  • Measuring method: TOC determination by UV digestion and measurement of the differential conductivity

Water hardness analyzer Liquiline System CA80HA

Colorimetric system for online monitoring of drinking water and process water

Predecessor: Stamolys CA71HA

 

  • Measurement range: 0 to 80 mg/l CaCO3

    0 to 80 mg/l with dilution function to maximum 16 to 1600 mg/l CaCO3

  • Process temperature: 4 to 40 °C (39 to 104 °F)

  • Process pressure: Unpressurized

Silica analyzer Liquiline System CA80SI

Colorimetric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers

Predecessor: Stamolys CA71SI

  • Measurement range: 0 to 500 µg/l (ppb), 50 to 5000 µg/l (ppb)
  • Process temperature: 5 to 45 °C (41 to 113 °F)
  • Process pressure: 1 to 5 bar (14.5 to 72.5 psi)
  • Measuring method: Comply with standard colorimetric measuring principle – heteropoly blue method

TN analyzer Liquiline System CA80TN

Total nitrogen analyzer for environmental monitoring, industrial and municipal wastewater

  • Measurement range: 0 to 10 mg/l N, 0 to 50 mg/l N, 0 to 200 mg/l N
  • Process temperature: 4 to 40 °C (39.2 to 104 °F)
  • Process pressure: At atmospheric pressure, < 0.2 bar

Digital ammonium and nitrate sensor ISEmax CAS40D

Ion-selective Memosens sensor for the wastewater industry

Predecessor: ISEmax CAS40

  • Measurement range: Ammonium: 0.1 to 1000 mg/l (NH4-N)

Nitrate: 0.1 to 1000 mg/l (NO3-N)

Potassium: 1 to 1000 mg/l
Chloride:1 to 1000 mg/l

  • Process temperature: 2 °C to 40°C (36 to 100 °F)
  • Process pressure: 400 mbar (160 in H2O) max. permitted overpressure

Spectrometer Memosens Wave CAS80E

UV-VIS spectrometer for the water & wastewater industry

  • Measurement range: Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l

CODeq: 0 to 20 000 mg/l
BODeq: 0 to 5000 mg/l
SAC254: 0 to 1000 /m
TU: 0 to 800 FAU
TSS: 0 to 10 000 mg/l
NO3-N: 0 to 500 mg/l
APHA/Hazen: 0 to 500 Hazen

  • Process temperature: 0 to 50°C, 32 to 122 °F
  • Process pressure: 0.5 to 10 bar abs., 7.3 to 145 psi
  • Measuring method: UV/VIS Absorbance at 200 to 800 nm

Sample preparation Stamoclean CAT411

Self-cleaning crossflow filter for pressurized pipe sampling

  • Process temperature: 5 to 50 °C (41 to 122 °F)
  • Process pressure: 0.2 to 1 bar (3 to 15 psi)

 

Sample preparation Liquiline System CAT810

Self-cleaning backflush filter for sampling from pressurized pipes and outlets

Predecessor: Stamoclean CAT221

  • Process temperature: 4 to 40 °C (39 to 104 °F)
  • Process pressure: 1.5 to 4.0 bar (21.76 to 58.01 psi)
  • For optional automatic cleaning: 2.0 to 5.0 bar (29.0 to 72.5 psi); but at least 0.5 bar (7.3 psi) > process pressure

Sample preparation Liquiline System CAT820

In-situ filtration system for sampling in wastewater treatment plants and surface waters

Predecessor: Stamoclean CAT430

  • Process temperature: 4 to 40 °C (39 to 104 °F)
  • Process pressure: Unpressurized

Sample preparation Liquiline System CAT860

Robust in-situ filtration system for sampling from inlets of wastewater treatment plants

  • Process temperature: 4 to 40 °C (39 to 104 °F)
  • Process pressure: Unpressurized

Flow assembly CAV01

Flow assembly for optical, chemical-free concentration measurement in drinking water and process water

  • Process temperature: 0 to 50°C, 32 to 122 °F
  • Process pressure: 0 to 6 bar abs. 0 to 87 psi

 

Flow assembly Flowfit CCA250

Products
Liquid Analysis

Assembly for chlorine measurement in drinking, industrial, and pool water

Successor: Flowfit CYA27
Hide details

  • Process temperature: max. 45°C
  • Process pressure: max. 4bar

Disinfection transmitter Liquisys CCM223

Compact panel device for the water, wastewater, food and power industries

Predecessor: CCM120, CCM121

  • Input: Chor / Chlordioxide and pH/ORP Sensor.
  • Output / communication: – Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA

Disinfection transmitter Liquisys CCM253

Compact field device for the water, wastewater, food and power industries

Predecessor: CCM130, CCM140, CCM141S, CCM151, CCM141

  • Input: Chorine / Chlordioxide and pH/ORP Sensor.
  • Output / communication: – Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA

Analog total chlorine sensor CCS120

Disinfection sensor for all water and wastewater applications

  • Measurement range: 0,1 – 10ppm total chlorine; pH 6,5 – 9,5
  • Process temperature: 5°C – 45°C
  • Process pressure: 0bar – 3bar

CCS50: Analog chlorine dioxide sensor

Sensor for water, process water and utilities in all industries

Predecessor: Chlorine dioxide CCS240, Trace Chlorine dioxide CCS241
Hide details

  • Measurement range:  Trace: 0 to 5 mg/l ClO2, Standard: 0 to 20 mg/l ClO2
  • Process temperature: 0 to 55 °C (32 to 130°F), non-freezing
  • Process pressure: Max.1 bar (max. 14.5 psi)
  • Measuring method: Closed, membrane covered measuring cell, Reduction of chlordioxide at the cathode

Digital chlorine dioxide sensor Memosens CCS50E

Memosens sensor for drinking water, process water and multi-industry utilities

  • Measurement range: Trace: 0 to 5 mg/l ClO2, Standard: 0 to 20 mg/l ClO2, High: 0 to 200 mg/l ClO2
  • Process temperature: 0 to 55 °C , non-freezing (32 to 130 °F)
  • Process pressure: Max. 2 bar abs (Max. 29 psi abs)

Digital free chlorine sensor Memosens CCS51E

Memosens sensor for drinking water, pool and process water as well as utilities in all industries

  • Measurement range: Trace: 0 to 5 mg/l HOCl, Standard: 0 to 20 mg/l HOCl, High: 0 to 200 mg/l HOCl
  • Process temperature: 0 to 55 °C (32 to 130 °F), non-freezing
  • Process pressure: Max. 1 bar (max. 14.5 psi)
  • Measuring method: Closed, membrane covered measuring cell, Reduction of free chlorine at the cathode

Digital free bromine sensor Memosens CCS55E

Memosens sensor for seawater applications and process water

  • Measurement range: Trace: 0 … 5 mg/l HOBr, Standard: 0 … 20 mg/l HOBr, High: 0 … 200 mg/l HOBr
  • Process temperature: +0…55 °C (32 … 130°F), non-freezing
  • Process pressure: Max. 1 bar (max. 14.5 psi)

Digital ozone sensor Memosens CCS58E

Memosens sensor for wastewater, process water in all industries and drinking water

  • Measurement range: 0 to 2 mg/l
  • Process temperature: +0 to 45 °C (32 to 110 °F), non freezing
  • Process pressure: 1 bar (14.5 psi), 2 bar (29 psi) absolute
  • Measuring method: – closed 2 electrode system

– conversion of ozone into a signal current in nA
– signal current is proportional to the concentration of ozone
– the measurement is not pH dependent

Conductivity assembly Dipfit CLA111

Immersion assembly for water, wastewater and utilities

  • Process temperature: Max. 80 °C (176 °F)
  • Process pressure: Max. 4 bar at 20 °C, (Max. 58 psi at 68 °F)

Conductivity assembly Dipfit CLA140

Immersion assembly for the chemical and the pulp & paper industry

Predecessor: CLA110

  • Process temperature: max. 150°C, (302°F)
  • Process pressure: max. 10 bar, (145 psi)

Conductivity compact device Smartec CLD132

Inductive conductivity measuring system for applications with fast temperature changes

Predecessor: CLD130, CLS51

  • Measurement range:  100 µS/cm – 2000 mS/cm
  • Process temperature: max. 140°C (max. 30 min.), 284°F (max. 30 min.)
  • Process pressure: max. 12 bar (90°C), (174 psi(194°F))

Digital conductivity sensor Memosens CLL47E

Memosens 2.0 four-electrode sensor for laboratory and sample measurement in the field with wide measuring range

  • Measurement range: 5 μS/cm to 200 mS/cm
  • Process temperature: 0 to 100 °C (32 to 212 °F)
  • Process pressure: 1 bar, not intended for continuous measurement in process

Conductivity transmitter Liquisys CLM223

Compact panel device for all industries

Predecessor: CLM121, CLM230, CLM210, CLM170, CLM140, CLM120, CLM220, CLM221

  • Input: 1-channel transmitter
  • Output / communication: 0/4-20 mA, Hart, Profibus.
  • Ingress protection: IP65

Conductivity transmitter Liquisys CLM253

Compact field device for all industries

Predecessor: CLM141S, CLM141, CLM170, CLM130, CLM240, CLM151, CLM252

  • Input: One-channel transmitter
  • Output / communication: 0/4-20mA, Hart, Profibus.
  • Ingress protection: IP65

Analog conductivity sensor Condumax CLS12

Conductive conductivity sensor for high temperature applications in the power & energy industry

Predecessor: CLS11

  • Measurement range: k=0.01: 0 to 20 µS/cm, k= 0.1: 0 to 200 µS/cm
  • Process temperature:  -30 to 160 °C (-22 to 320 °F)
  • Process pressure: Max. 40 bar up to 100 °C (max. 580 psi up to 212 °F) without CLA 751 flow chamber, Max. 12 bar up to 150 °C (max. 174 psi up to 302 °F) with CLA 751 flow chamber

Analog conductivity sensor Condumax CLS13

Conductive conductivity sensor for high temperature applications in the power & energy industry

  • Measurement range: k=0,01: 0-20,0 µS/cm, k=0,1: 0-200,0 µS/cm
  • Process temperature: max. 250 °C (482 °F)
  • Process pressure: max. 40 bar (580 psi)