Level measurement
Endress+Hauser Level measurement is one of the world’s leading providers of measuring instruments and complete systems for Level measurementt.
Products List
Conductive Point level detection One rod probe 11375Z
Simple point level detection of conductive liquids with higher temperatures
Predecessor: One rod probe 11375ZF, One rod probe 11375
- Process temperature: -40 °C … 135 °C
(-40 °F … 275 °F) - Process pressure / max. overpressure limit: Vacuum … 50 bar
(Vacuum … 725 psi) - Min. conductivity of medium: 20 µS/cm
Conductive Point level detection One rod probe 11961Z
High resistance point level detection of conductive liquids steam boilers and aggressive media
Predecessor: One rod probe 11961ZF, One rod probe 11961
- Process temperature: -200 °C … 250 °C
(-328 °F … 482 °F) - Process pressure / max. overpressure limit: Vacuum … 160 bar
(Vacuum … 2320 psi)
Min. conductivity of medium: 20 µS/cm
Microwave barrier transceiver Soliwave FDR16
Ultra-compact microwave barrier for non-contact point level detection, piece goods counting and object detection
- Process temperature: Non-contact installation: any
Within installation:
–20 °C … +60 °C (–4 °F … +140 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With HP-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Microwave barrier transceiver Soliwave FDR56
Transceiver for non-contact point level detection in bulk solids
- Process temperature: Non-contact installation: any
Within installation:
-40 °C…+70 °C (-40 °F…+158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Microwave barrier transceiver Soliwave FDR57
Transceiver for non-contact point level detection and bulk flow monitoring
Predecessor: Soliwave FDR50
- Process temperature: Non-contact installation: any
Within installation:
-40 °C … +70 °C
(-40 °F … +158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar
(7.2 psi … 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Radiometric measurement Synchronizer FHG66
Synchronization of an unlimited number of Gamma Modulators FHG65 for unhindered measurement
Radar measurement Time-of-Flight Micropilot FMR53
For simple level measurement applications in liquids
Predecessor: Micropilot M FMR231
- Accuracy: +/- 6 mm (0.24 in)
- Process temperature: -40…+150 °C
(-40…+302 °F) - Process pressure / max. overpressure limit: Vacuum…40 bar
(Vacuum…580 psi) - Max. measurement distance: Standard: 20 m (66 ft)
- Main wetted parts: PTFE, PVDF
Radar measurement Micropilot FMR532
For high accurate non-contact level measurement in stilling well applications in custody transfer
- Accuracy: +/- 1 mm, custody transfer
- Process temperature: -40 °C … 150 °C
(-40 °F … 302 °F) - Process pressure / max. overpressure limit: Vacuum … 25 bar
(Vaccum … 362 psi) - Max. measurement distance: 40 m (131 ft)
Main wetted parts: 316L + PTFE
Radar measurement Micropilot FMR540
Horn antenna and parabolic antenna for custody transfer applications
Predecessor: Micropilot S FMR530, Micropilot S FMR533
- Accuracy: +/- 1 mm
- Process temperature: -40°C…200°C
(-40°F…392°F) - Process pressure / max. overpressure limit: Horn: Vacuum…16 bar (232 psi)
Parabolic: Vacuum…6 bar (87 psi)
Use of UNIflange: Vacuum…1 bar (14.5 psi) - Main wetted parts: 316L
Microwave barrier transceiver Soliwave FQR16
Ultra-compact microwave barrier for non-contact point level detection, piece goods counting and object detection
- Process temperature: Non-contact installation: any
Within installation:
-20 °C … +60 °C (-4 °F … +140 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With HP-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Microwave barrier transmitter Soliwave FQR57
Transmitter for non-contact point level detection and bulk flow monitoring
Predecessor: Soliwave FQR50
- Process temperature: Non-contact installation: any
Within installation:
-40 °C…+70 °C
(-40 °F…+158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar…6.8 bar
(7.2 psi … 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Radiometric level and density measurement Gamma Source FSG60
Gamma radiation source (137Cs) for radiometric level, point level, density and interface measurement
- Process pressure / max. overpressure limit: Any
Radiometric level and density measurement Gamma Source FSG61
Gamma radiation source (60Co) for radiometric level, point level, density and interface measurement
- Process temperature: Any
- Process pressure / max. overpressure limit: Any
Capacitance Point level switch Nivotester FTC325
Point level switch with intrinsically safe signal circuit for connection to a capacitance sensor
Predecessor: Transmitter FTC520Z, Transmitter FTC521Z, Transmitter FTC625, Transmitter FTC421, Transmitter FTC422, Transmitter FTC420
Vibronic Point level detection Nivotester FTL325N
Switching unit with NAMUR input for rail mounting or single installation
Predecessor: Nivotester FTL375N
Vibronic Point level detection Nivotester FTL325P
Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant
Predecessor: Nivotester FTL375P, FTL32
Microwave flow indicator Solimotion FTR16
Ultra-compact flow indicator for monitoring pneumatic and mechanical transport processes of bulk solids
- Process temperature: Non-contact installation: any
Within installation:
–20 °C … +60 °C (–4 °F … +140 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With HP-Adapter:
up to +21 bar (+305 psi) abs. - Min. density of medium: Solid weight: > 10 g/l
Microwave flow indicator Solimotion FTR20
For monitoring pneumatic and mechanical transport processes for bulk solids
- Process temperature: Standard
-40°C … +70°C
(-40°F …158°F)
With adapter for temperature reduction:
-40°C to +450°C
-40°F …+842°F) - Process pressure / max. overpressure limit: 0.5 … 6.8 bar abs standard, (7.2 … 98.6 psi abs)
When using the adapter for temperature reduction: 0.8 to 5.1 bar abs, (11.6 …74 psi abs)
For monitoring pneumatic and mechanical transport processes for bulk solids
- Process temperature: Standard
-40°C … +70°C
(-40°F …158°F)
With adapter for temperature reduction:
-40°C to +450°C
-40°F …+842°F) - Process pressure / max. overpressure limit: 0.5 … 6.8 bar abs standard, (7.2 … 98.6 psi abs)
When using the adapter for temperature reduction:, 0.8 to 5.1 bar abs, (11.6 …74 psi abs)
Nivotester FTR525 Process transmitter for FQR57/FDR57
Process transmitter with control unit for Soliwave FQR57/FDR57
Predecessor: Nivotester FTR325
Conductive Point level switch Nivotester FTW325
Point level switch with intrinsically safe signal circuit for connection to a conductive sensor
Predecessor: FTW420, FTW470Z, FTW570Z, FTW520Z
- Min. density of medium: min. 10 uS
Tank gauging Analogue Transmitter AT1
For remote monitoring of a tank
Predecessor: AT500
Tank gauging instrument Float Gauge LT5
Mechanical tank gauge for accurate and reliable level measurement
Predecessor: Float Gauge LT11, Float Gauge LT12, LT14, LT16
- Process temperature: -200 °C … 200 °C
(-328 °F … 392 °F) - Process pressure / max. overpressure limit: 1bar abs…24.5 bar abs
15 psi…355.25 psi - Accuracy: up to ±2mm (+/- 0.08″)
Tank gauging Magnet Level Switch MPC2
Displacement technology level switch
Float Sensor NAR300 - Oil leak detector Oil leak detector Float Sensor NAR300
Leak detection of petrochemicals, vegetable oils and others
Oil leak detector Transmitter NRR261
Oil leak detection system provides excellent leak detection of petrochemicals, vegetable oils, etc.
Oil leak detector Transmitter NRR262
Oil leak detection system provides excellent leak detection of petrochemicals, vegetable oils, etc.
Tank gauging Digital Transmitter TMD1
For remote calibration of a tank