Level measurement
Endress+Hauser Level measurement is one of the world’s leading providers of measuring instruments and complete systems for Level measurementt.
Products List
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquipoint_FTW32_PP-300x300.jpg)
Conductive Point level detection Liquipoint FTW32
Rope probe for multipoint detection for up to 5 switch points
Predecessor: One rode probe 11263, 21373, FTW131
- Process temperature: -40 °C … 70 °C
(-40 °F … 158 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Min. conductivity of medium: 10 µS/cm
![](https://tecteslabd.com/wp-content/uploads/2023/12/NMS80-L-edited_Proservo_PP-300x300.jpg)
Servo tank gauging instrument Proservo NMS80
High precision servo measurement for liquid level, interface and density
Predecessor: Proservo NMS5
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C
(-328°F…392°F) - Process pressure / max. overpressure limit: 0,2…6 bar abs
- Max. measurement distance: 36 m (118 ft)
- Main wetted parts: 316L, AlloyC276, PTFE
![](https://tecteslabd.com/wp-content/uploads/2023/12/NMS81-L-edited_Proservo_PP-300x300.jpg)
Servo tank gauging instrument Proservo NMS81
High precision servo measurement for liquid level, interface and density
Predecessor: Proservo NMS5
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C, (-328°F…392°F)
- Process pressure / max. overpressure limit: up to 25 bar (363 psi) abs
- Max. measurement distance: 47 m (154 ft)
- Main wetted parts: 316L, AlloyC276, PTFE
![](https://tecteslabd.com/wp-content/uploads/2023/12/Gamma_Modulator_FHG65_PP-300x300.jpg)
Radiometric measurement Gamma Modulator FHG65
Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquicap_FMI21_PP-300x300.jpg)
Capacitance Level measurement Liquicap FMI21
For continuous level measurement in conductive liquids
Predecessor: T6667, Double rod probe 11304Z
- Accuracy: < 1%
- Process temperature: -40 °C … 100 °C
(-40 °F … 212 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Max. measurement distance: 2.5 m (8 ft)
- Main wetted parts: Probe rods:, 316L/1.4404 / PP, Option: carbon fibre PP coated
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquicap_FMI52_PP_1-300x300.jpg)
Capacitance Level measurement Liquicap FMI52
For continuous level and interface measurement in liquids – for large measuring ranges
Predecessor: Silometer FMC420, Float Gauge LTC2230, T6667, Multicap DC21, DC26, Double rod probe 11304Z, Multicap T DC21TEN, DC26TEN, Multicap DC21AN, Multicap DC21EN, DC26AN, DC26EN, Multicap DC21AS, Multicap DC21ES, DC26AS, DC26ES, Multicap T DC21TAS, DC26TAS, Multicap T DC21TAN, DC26TAN, Multicap T DC21TES, DC26TES
- Accuracy: repeatablity 0,1%
- Process temperature: -80°C…200°C
-112°F…392°F - Process pressure / max. overpressure limit: Vacuum … 100 bar
(Vaccum … 1450 psi) - Max. measurement distance: 0.42 m … 10.0 m
(1.38 ft … 33 ft) - Main wetted parts: Insulation material: FEP,PFA, 316L
![](https://tecteslabd.com/wp-content/uploads/2023/12/Silopilot_FMM20_PP_1-300x300.jpg)
Electromechanical Level measurement Silopilot FMM20
Basic model for continuous level measurement in light bulk solids
- Accuracy: +/- 2.5 cm (0.98″)
- Process temperature: -20°C … +150°C
(-4°F…302°F) - Process pressure / max. overpressure limit: 0.8 … 1.1 bar abs.
(11.6psi …15.95psi abs.) - Max. measurement distance: 32m (105ft)
- Main wetted parts: Aluminium, Steel, Stainless steel
![](https://tecteslabd.com/wp-content/uploads/2023/12/Silopilot_FMM50_PP_1-300x300.jpg)
Electromechanical Level measurement Silopilot FMM50
For continuous level measurement even in high bulk solids silos or bins
Predecessor: Silopilot FMM760, FMM760Z
- Accuracy: +/- 5 cm
- Process temperature: -20°C … +230°C
(-4°F … 446°F) - Process pressure / max. overpressure limit: 0.8 … 3 bar abs.
(11.6psi …43.5psi abs.) - Max. measurement distance: 70m (230ft)
- Main wetted parts: Aluminium, Steel, Stainless steel
![](https://tecteslabd.com/wp-content/uploads/2023/12/Micropilot_FMR50_PP_1-300x300.jpg)
Radar measurement Time-of-Flight Micropilot FMR50
Basic model for level liquid applications
Predecessor: Micropilot M FMR244
- Accuracy: +/- 2 mm (0.08 in)
- Process temperature: -40…+130 °C
(-40…+266 °F) - Process pressure / max. overpressure limit: Vacuum…3 bar
(Vacuum…43.5 psi) - Max. measurement distance: Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft) - Main wetted parts: PVDF, Viton, PP, PBT
![](https://tecteslabd.com/wp-content/uploads/2023/12/Micropilot_FMR56_PP_1-300x300.jpg)
Radar measurement Time-of-Flight Micropilot FMR56
Economically efficient basis model for level measurement in solids
Predecessor: Micropilot M FMR244, Prosonic S FDU96
- Accuracy: +/- 3 mm (0.12 in)
- Process temperature: -40 °C…+80 °C
(-40 °F…+176 °F) - Process pressure / max. overpressure limit: Vacuum…3 bar
(Vacuum…43.5 psi) - Max. measurement distance: 30 m (98 ft)
- Main wetted parts: PP, UP
![](https://tecteslabd.com/wp-content/uploads/2023/12/Micropilot_FMR60_PP_2-300x300.jpg)
Radar measurement Micropilot FMR60
The standard sensor for highest demands in liquid level measurement with 80GHz technology
- Accuracy: +/- 1 mm (0.04 in)
- Process temperature: -40…+130 °C
(-40…+266 °F) - Process pressure / max. overpressure limit: Vacuum …16 bar
(Vacuum … 232 psi) - Max. measurement distance: 50 m (164 ft)
- Main wetted parts
- PTFE antenna: PP or 316L process connections
![](https://tecteslabd.com/wp-content/uploads/2023/12/Micropilot_FMR62_PP_3-300x300.jpg)
Radar measurement Micropilot FMR62
For 80GHz level measurement in aggressive liquids or applications with hygiene requirements
- Accuracy: +/- 1 mm (0.04 in)
- Process temperature: -40…+200 °C
(-40…+392 °F) - Process pressure / max. overpressure limit: Vacuum…+25 bar
(Vacuum…+362.6 psi) - Max. measurement distance: 80 m (262 ft)
- Main wetted parts: PTFE or PEEK antenna, 316L threads, PTFE cladded flanges
![](https://tecteslabd.com/wp-content/uploads/2023/12/Micropilot_FMR67_PP_3-300x300.jpg)
Radar measurement Micropilot FMR67
The standard sensor for highest demands in bulk solids level measurement with 80GHz technology
- Accuracy: +/- 3 mm (0.12 in)
- Process temperature: -40…+200 °C
(-40…+392 °F) - Max. measurement distance: 125 m (410 ft)
- Main wetted parts: PTFE, 316L, Alignment device: Alu
![](https://tecteslabd.com/wp-content/uploads/2023/12/Waterpilot_FMX11_PP_1-300x300.jpg)
Hydrostatic Level measurement Waterpilot FMX11
Simple and reliable level probe for freshwater applications
- Accuracy: pn ≥ 400mbar: 0.35 %
pn < 400mbar: 0.50 % - Process temperature: -10°C…+70°C
(+14°F…+158°F) - Pressure measuring range: 200 mbar…2 bar
(3 psi…29 psi) - Process pressure / max. overpressure limit: 10 bar (145 psi)
- Main wetted parts: 316L
- Max. measurement distance: 20 m H2O
(66 ft H2O) - Material process membrane: Metal
- Measuring cell: 200 mbar…2 bar, (3 psi…29 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Waterpilot_FMX21_stainless_steel_housing_PP_5-300x300.jpg)
Hydrostatic Level measurement Waterpilot FMX21
Reliable and robust level probe with ceramic measuring cell and HART
Predecessor: Waterpilot FMX167
- Accuracy: 0.2%
0.1% (optional) - Process temperature: -10°C…70°C
(14°F…158°F)
Diameter 29 mm (1.14″): 0°C…50°C
(32°F…122°F) - Pressure measuring range: 100 mbar…20 bar
(1.5 psi…300 psi) - Main wetted parts: Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
Extension cable: PE, PUR, FEP - Max. measurement distance: 200 m H2O
(656 ft H2O) - Measuring cell: 100mbar…20bar, (1.5psi…300psi)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Source_Container_FQG66_PP_3-300x300.jpg)
Radiometric Level and density Source Container FQG66
Radiation source container with sliding source support rod for manual or pneumatic on/off switching
Predecessor: Source container QG2000
- Process temperature: Any
- Process pressure / max. overpressure limi: Any
- Main wetted parts: Non-contact
![](https://tecteslabd.com/wp-content/uploads/2023/12/Soliwave_FQR56_PP-300x300.jpg)
Microwave barrier transmitter Soliwave FQR56
Transmitterfor non-contact point level detection in bulk solids
- Process temperature: Non-contact installation: any
Within installation:
-40 °C…+70 °C (-40 °F…+158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any, Within installation: 0.5 bar…6.8 bar (7.2 psi…99 psi) abs. With HD-Adapter: up to +21 bar (+305 psi) abs., Min. density of medium, Solid weight: > 10 g/l
![](https://tecteslabd.com/wp-content/uploads/2023/12/Minicap_FTC260_PP-300x300.jpg)
Capacitance Point level detection Minicap FTC260
Designed for light bulk solids
Predecessor: FTC731, FTC730
- Process temperature: -40 °C … 120°C
(-40 °F … 248 °F)
Process pressure / max. overpressure limit: -1 … 25 bar, (-14.5 … 360 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Minicap_FTC262_alu_PP_1-300x300.jpg)
Capacitance Point level detection Minicap FTC262
Designed for light bulk solids
Predecessor: FTC831, FTC830
- Process temperature: -40 °C … 80 °C
- (-40 °F … 176 °F)
Process pressure / max. overpressure limit: -1 … 6 bar(-14.5 … 90 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Soliswitch_FTE30_PP-300x300.jpg)
Point level switch Soliswitch FTE30 rotary paddle switch
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Predecessor: FTE130, FTE330
Successor: Soliswitch FTE20
- Process temperature: -20 °C … 80 °C (-4 °F … 170 °F)
Process pressure / max. overpressure limit: 0.5 bar to 1.5 bar (7 psi to 22 psi) - Min. density of medium: >= 100 g/l
![](https://tecteslabd.com/wp-content/uploads/2023/12/fte31-300x300.jpg)
Point level switch Soliswitch FTE31 Rotary paddle switch
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Successor: Soliswitch FTE20
- Process temperature: -20 °C … 80 °C (-4 °F … 170 °F)
- Process pressure / max. overpressure limit: 0.5 bar to 1.5 bar (7 psi to 22 psi)
- Min. density of medium: >= 100 g/l
![](https://tecteslabd.com/wp-content/uploads/2023/12/Nivector_FTI26_PP_1-300x300.jpg)
Capacitance Point level detection Nivector FTI26
For all types of powdered and fine-grained solids especially in the food industry
- Process temperature: -40°C…80°C, (-40°F…176°F)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquiphant_FTL50H_PP_1-300x300.jpg)
Vibronic Point level detection Liquiphant FTL50H
Compact vibration point level switch for liquids especially in the food and life sciences industry
Predecessor: CS1103, CS1113, CS1203, CS1213, CS1603, CS1613, Liquiphant FTL330H, Liquiphant FTL330L
- Process temperature: -50 °C…+150 °C
(-58 °F…+302 °F) - Process pressure / max. overpressure limit: Vacuum…64 bar
(Vacuum…928 psi) - Min. density of medium: 0.5g/cm³(0.4g/cm³ optional)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquiphant_FTL51H_PP_1-300x300.jpg)
Vibronic Point level detection Liquiphant FTL51H
Point level switch with extension tube for liquids especially in the food and life sciences industry
Predecessor: CS1103, CS1113, CS1203, CS1213, CS1603, CS1613, Liquiphant FTL330H, Liquiphant FTL330L, FTL360, FTL361, FDL30, FDL31, FTL365, FTL366, FDL35, FDL36
- Process temperature: -50 °C…+150 °C
(-58 °F…+302 °F) - Process pressure / max. overpressure limit: Vacuum…64 bar
(Vacuum…928 psi) - Min. density of medium: 0.5g/cm³ (0.4g/cm³ optional)
![](https://tecteslabd.com/wp-content/uploads/2023/12/Nivotester_FailSafe_FTL825_PP-300x300.jpg)
Vibronic Point level detection Nivotester FailSafe FTL825
Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85
![](https://tecteslabd.com/wp-content/uploads/2023/12/NMS83-L-edited_Proservo_PP-300x300.jpg)
Servo tank gauging instrument Proservo NMS83
High precision servo measurement for liquid level, interface and density for hygienic applications
Predecessor: Proservo NMS7
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C
(-328°F…392°F) - Process pressure / max. overpressure limit: 6 bar abs
- Max. measurement distance: 22 m (72 ft)
- Main wetted parts: 316L, AlloyC276, PTFE
![](https://tecteslabd.com/wp-content/uploads/2023/12/Liquifloat_FTS20_PP-300x300.jpg)
Float switch Liquifloat FTS20
For point level detection in liquids
![](https://tecteslabd.com/wp-content/uploads/2023/12/Double_rod_probe_11362Z_PP-300x300.jpg)
Conductive Point level detection Double rod probe 11362Z
High resistant probes for corrosive liquids in plastic vessels
Predecessor: 11362
- Process temperature: -40 °C … 150 °C
(-40 °F … 302 °F) - Process pressure / max. overpressure limit: Vacuum … 30 bar
(Vacuum … 435 psi) - Min. conductivity of medium: 20 µS/cm
![](https://tecteslabd.com/wp-content/uploads/2023/12/Triple_rod_probe_11363Z_PP-300x300.jpg)
Conductive Point level detection Triple rod probe 11363Z
High resistant probes for corrosive liquids in plastic vessels
Predecessor: 11363
- Process temperature: -40 °C … 150 °C
(-40 °F … 302 °F) - Process pressure / max. overpressure limit: Vacuum … 30 bar
(Vacuum … 435 psi) - Min. conductivity of medium: 20 µS/cm
![](https://tecteslabd.com/wp-content/uploads/2023/12/One_rod_probe_11371_PP-300x300.jpg)
Conductive Point level detection One rod probe 11371
Point level detection of conductive liquids in the food industry
Predecessor: ST11370, 11370
- Process temperature: -10 °C … 100 °C
(+10 °F … +210 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Min. conductivity of medium: 20 µS/cm