Product Category

Level measurement

Endress+Hauser Level measurement is one of the world’s leading providers of measuring instruments and complete systems for Level measurementt.

Products List

Conductive Point level detection One rod probe 11375Z

Simple point level detection of conductive liquids with higher temperatures

Predecessor: One rod probe 11375ZF, One rod probe 11375

  • Process temperature: -40 °C … 135 °C
    (-40 °F … 275 °F)
  • Process pressure / max. overpressure limit: Vacuum … 50 bar
    (Vacuum … 725 psi)
  • Min. conductivity of medium: 20 µS/cm

 

Conductive Point level detection One rod probe 11961Z

High resistance point level detection of conductive liquids steam boilers and aggressive media

Predecessor: One rod probe 11961ZF, One rod probe 11961

  • Process temperature: -200 °C … 250 °C
    (-328 °F … 482 °F)
  • Process pressure / max. overpressure limit: Vacuum … 160 bar
    (Vacuum … 2320 psi)
    Min. conductivity of medium: 20 µS/cm

 

Microwave barrier transceiver Soliwave FDR16

Ultra-compact microwave barrier for non-contact point level detection, piece goods counting and object detection

  • Process temperature: Non-contact installation: any
    Within installation:
    –20 °C … +60 °C (–4 °F … +140 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
    With HP-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Microwave barrier transceiver Soliwave FDR56

Transceiver for non-contact point level detection in bulk solids

  • Process temperature: Non-contact installation: any
    Within installation:
    -40 °C…+70 °C (-40 °F…+158 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
    With HD-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Microwave barrier transceiver Soliwave FDR57

Transceiver for non-contact point level detection and bulk flow monitoring

Predecessor: Soliwave FDR50

  • Process temperature: Non-contact installation: any
    Within installation:
    -40 °C … +70 °C
    (-40 °F … +158 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar
    (7.2 psi … 99 psi) abs.
    With HD-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Radiometric measurement Synchronizer FHG66

Synchronization of an unlimited number of Gamma Modulators FHG65 for unhindered measurement

Radar measurement Time-of-Flight Micropilot FMR53

For simple level measurement applications in liquids

Predecessor: Micropilot M FMR231

  • Accuracy: +/- 6 mm (0.24 in)
  • Process temperature: -40…+150 °C
    (-40…+302 °F)
  • Process pressure / max. overpressure limit: Vacuum…40 bar
    (Vacuum…580 psi)
  • Max. measurement distance: Standard: 20 m (66 ft)
  • Main wetted parts: PTFE, PVDF

 

Radar measurement Micropilot FMR532

For high accurate non-contact level measurement in stilling well applications in custody transfer

  • Accuracy: +/- 1 mm, custody transfer
  • Process temperature: -40 °C … 150 °C
    (-40 °F … 302 °F)
  • Process pressure / max. overpressure limit: Vacuum … 25 bar
    (Vaccum … 362 psi)
  • Max. measurement distance: 40 m (131 ft)
    Main wetted parts: 316L + PTFE

 

Radar measurement Micropilot FMR540

Horn antenna and parabolic antenna for custody transfer applications

Predecessor: Micropilot S FMR530, Micropilot S FMR533

  • Accuracy: +/- 1 mm
  • Process temperature: -40°C…200°C
    (-40°F…392°F)
  • Process pressure / max. overpressure limit: Horn: Vacuum…16 bar (232 psi)
    Parabolic: Vacuum…6 bar (87 psi)
    Use of UNIflange: Vacuum…1 bar (14.5 psi)
  • Main wetted parts: 316L

 

Microwave barrier transceiver Soliwave FQR16

Ultra-compact microwave barrier for non-contact point level detection, piece goods counting and object detection

  • Process temperature: Non-contact installation: any
    Within installation:
    -20 °C … +60 °C (-4 °F … +140 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
    With HP-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Microwave barrier transmitter Soliwave FQR57

Transmitter for non-contact point level detection and bulk flow monitoring

Predecessor: Soliwave FQR50

  • Process temperature: Non-contact installation: any
    Within installation:
    -40 °C…+70 °C
    (-40 °F…+158 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar…6.8 bar
    (7.2 psi … 99 psi) abs.
    With HD-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Radiometric level and density measurement Gamma Source FSG60


Gamma radiation source (137Cs) for radiometric level, point level, density and interface measurement

  • Process pressure / max. overpressure limit: Any

 

Radiometric level and density measurement Gamma Source FSG61

Gamma radiation source (60Co) for radiometric level, point level, density and interface measurement

  • Process temperature: Any
  • Process pressure / max. overpressure limit: Any

 

Capacitance Point level switch Nivotester FTC325

Point level switch with intrinsically safe signal circuit for connection to a capacitance sensor

Predecessor: Transmitter FTC520Z, Transmitter FTC521Z, Transmitter FTC625, Transmitter FTC421, Transmitter FTC422, Transmitter FTC420

Vibronic Point level detection Nivotester FTL325N

Switching unit with NAMUR input for rail mounting or single installation

Predecessor: Nivotester FTL375N

Vibronic Point level detection Nivotester FTL325P

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant

Predecessor: Nivotester FTL375P, FTL32

Microwave flow indicator Solimotion FTR16

Ultra-compact flow indicator for monitoring pneumatic and mechanical transport processes of bulk solids

  • Process temperature: Non-contact installation: any
    Within installation:
    –20 °C … +60 °C (–4 °F … +140 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)
  • Process pressure / max. overpressure limit: Non-contact installation: any
    Within installation:
    0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
    With HP-Adapter:
    up to +21 bar (+305 psi) abs.
  • Min. density of medium: Solid weight: > 10 g/l

 

Microwave flow indicator Solimotion FTR20

For monitoring pneumatic and mechanical transport processes for bulk solids

  • Process temperature: Standard
    -40°C … +70°C
    (-40°F …158°F)
    With adapter for temperature reduction:
    -40°C to +450°C
    -40°F …+842°F)
  • Process pressure / max. overpressure limit: 0.5 … 6.8 bar abs standard, (7.2 … 98.6 psi abs)

When using the adapter for temperature reduction: 0.8 to 5.1 bar abs, (11.6 …74 psi abs)

For monitoring pneumatic and mechanical transport processes for bulk solids

  • Process temperature: Standard
    -40°C … +70°C
    (-40°F …158°F)
    With adapter for temperature reduction:
    -40°C to +450°C
    -40°F …+842°F)
  • Process pressure / max. overpressure limit: 0.5 … 6.8 bar abs standard, (7.2 … 98.6 psi abs)

When using the adapter for temperature reduction:, 0.8 to 5.1 bar abs, (11.6 …74 psi abs)

 

Nivotester FTR525 Process transmitter for FQR57/FDR57

Process transmitter with control unit for Soliwave FQR57/FDR57

Predecessor: Nivotester FTR325

Conductive Point level switch Nivotester FTW325

Point level switch with intrinsically safe signal circuit for connection to a conductive sensor

Predecessor: FTW420, FTW470Z, FTW570Z, FTW520Z

  • Min. density of medium: min. 10 uS

 

Tank gauging Analogue Transmitter AT1

For remote monitoring of a tank

Predecessor: AT500

Tank gauging instrument Float Gauge LT5

Mechanical tank gauge for accurate and reliable level measurement

Predecessor: Float Gauge LT11, Float Gauge LT12, LT14, LT16

  • Process temperature: -200 °C … 200 °C
    (-328 °F … 392 °F)
  • Process pressure / max. overpressure limit: 1bar abs…24.5 bar abs
    15 psi…355.25 psi
  • Accuracy: up to ±2mm (+/- 0.08″)

 

Tank gauging Magnet Level Switch MPC2

Displacement technology level switch

 

Float Sensor NAR300 - Oil leak detector Oil leak detector Float Sensor NAR300

Leak detection of petrochemicals, vegetable oils and others

Oil leak detector Transmitter NRR261

Oil leak detection system provides excellent leak detection of petrochemicals, vegetable oils, etc.

Oil leak detector Transmitter NRR262

Oil leak detection system provides excellent leak detection of petrochemicals, vegetable oils, etc.

Tank gauging Digital Transmitter TMD1

For remote calibration of a tank