Model: G3NA-210B-UTU DC5-24
Brand: OMRON
Solid State Relay, Phototriac, Applied output load: 10 A at 24 to 240 VAC, With zero cross function, Screw terminal, Certified by UL, CSA, and EN (TUV), Rated voltage 5 to 24 VDC
Product classification | For single-phase heater |
---|---|
Zero cross function | Equipped |
Operating indicator | Equipped |
Rated voltage | 5 to 24 VDC |
Rated load voltage | 24 to 240 VAC |
Load current | With heat sink (at 40 ℃): 0.1 to 10 A Without heat sink (at 40 ℃): 0.1 to 4 A |
Terminal structure | Screw terminal |
Product classification | For single-phase heater | |
---|---|---|
Number of phases | Single-phase | |
Isolation method | Phototriac | |
Zero cross function | Equipped | |
Operating indicator | Equipped | |
Terminal structure | Screw terminal | |
Mounting | Screw mounting | |
Input | Rated voltage | 5 to 24 VDC |
Operating voltage range | 4 to 32 VDC | |
Input current | 7 mA max.{V} (Constant current input circuit system) | |
Operate voltage | 4 V max.DC | |
Release voltage | 1 V min.DC | |
Output | Rated load voltage | 24 to 240 VAC |
Load voltage range | 19 to 264 VAC | |
Load current | With heat sink (at 40 ℃): 0.1 to 10 A Without heat sink (at 40 ℃): 0.1 to 4 A |
|
Inrush current resistivity | 150 A (60 Hz, 1 cycle) |
Operate time | 1/2 cycle of load power source + 1 ms max. |
---|---|
Release time | 1/2 cycle of load power source + 1 ms max. |
Output ON voltage drop | 1.6 V max. (RMS) |
Leakage current | 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 2,500 VAC, 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Shock resistance | 1000 m/s2 |
Ambient temperature (Operating) | -30 to 80 ℃ (with no freezing or condensation) |
Ambient temperature (Storage) | -30 to 100 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 45 to 85 % |
Weight | Approx. 60 g |