IoT Status Monitoring Amplifier
E9NC-AA / VA
IoT Status Monitoring Amplifiers for General-purpose Analog Outputs Are Connectable to Various Sensors
Ratings and specifications
Item |
Types |
Current input |
Voltage input |
||
Model for Sensor Communications Unit *1 |
|||||
NPN output |
E9NC-AA10 |
E9NC-AA0 |
E9NC-VA10 |
E9NC-VA0 |
|
PNP output |
E9NC-AA40 |
E9NC-VA40 |
|||
connection |
Connector for |
Connector for |
Connector for |
Connector for |
|
Output |
1 output *2 |
2 outputs *3 |
1 output *2 |
2 outputs *3 |
|
Power supply voltage |
24 VDC (20.4 to 26.4 V) class2 power is supplied from the connector via the communication |
||||
Power consumption |
24 V power supply voltage in normal mode: 1,080 mW or less (consumption current 45 mA |
||||
Sensor |
Voltage |
4 to 20 mA DC |
1 to 5 VDC |
||
Input |
204 kΩ±1% (Input: no-insulated) |
||||
Repeatability F.S./ |
±0.2% F.S. |
||||
Display accuracy F.S. |
±0.5% F.S. ±2digit |
||||
Temperature |
±1% F.S. |
||||
Control output |
Load power supply |
Refer to the |
Load power supply |
Refer to the |
|
Response Time |
1/10/100/500ms/1/10/30/60s (Initial value 500 ms) |
||||
Indicator |
Seven Segment Display (both sub and main digital display: white) |
||||
Protection circuit |
Power supply reverse |
Power supply |
Power supply reverse |
Power supply |
|
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, or percentage tuning (-99% to 99%)) or manual |
||||
Maximum connectable |
16 Units |
Model E3NW-ECT |
16 Units |
Model E3NW-ECT |
|
No. of Units for mutual |
None |
||||
Functions |
Operation |
NO (Normal Open)/NC (Normal Close) |
|||
Zero Reset |
Yes |
||||
Timer |
Select from timer disabled, OFF delay, ON delay, or One-shot timer |
||||
Scaling |
Set the upper/lower limits (-1999.9999 to 9999.9999, min. unit: 0.001) |
||||
Resetting |
Select from initial reset (factory defaults) or user reset (saved settings). |
||||
Eco mode |
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display |
||||
Bank |
Select from banks 1 to 4. |
||||
Output 1 |
Select from Normal detection mode or Wind comparator (area) detection mode. |
||||
Output 2 |
--- |
Select from Normal |
--- |
Select from Normal |
|
Hysteresis |
Select from standard setting or user setting. For a user setting, the hysteresis width can be |
||||
Display |
Select from normal display, peak/bottom display, or CH number display (setting value display |
||||
Key Lock |
Yes |
||||
Ambient temperature |
Operating: |
||||
Ambient humidity range |
Operating and storage: 35% to 85% RH (with no condensation) |
||||
Height |
2,000 m max. |
||||
Installation |
Pollution level 3 (according to IEC60947-1) |
||||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||||
Dielectric strength |
1,000 VAC 50/60Hz 1min |
||||
Vibration resistance |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions |
||||
Shock resistance |
150 m/s2 for 3 times each in X, Y and Z directions |
||||
Degree of protection |
IEC60529 IP50 |
||||
Weight (packed state/ |
Approx. 95 g/ |
Approx. 65 g/ |
Approx. 95 g/ |
Approx. 65 g/ |
|
Materials |
Case |
Polycarbonate (PC) |
|||
Cover |
Polycarbonate (PC) |
||||
Code |
Polyvinyl chloride (PVC) |
||||
Accessories |
Manual, 6-pin plug connector for connecting ECON cable (model XN2A-1670) x 1 |
1. The communication unit is compatible with EtherCAT type E3NW-ECT and E3NW-CCL of CC-Link. This unit is not usable with E3NW-CRT.
2. Channel 1 of each amplifier unit is output as the output drawn by the cord.
3. Output signals from two sensors are assigned to the PLC via the network. Various settings can be changed and detected values can be read by operating the PLC via the network.
4. This is the case of connecting with OMRON NJ series. For details, refer to the communication unit manual.
5. The bank is not reset by the user reset function or saved by the user save function.
6. Only E9NC-VA0/AA0 is able to connect to between 17 and 30 units.