Product Category

Safety-door Switch

D4BS

The Special Operation Key Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

Standards and EC Directives

Conforms to the following EC Directives:

・Machinery Directive
 ・EN50041
 ・EN ISO 14119
 ・EN 60204-1 

Certified Standards

Certification body

Standard

File No.

TÜV Rheinland

EN60947-5-1
 (certified direct opening)
 GS-ET-15

Consult your OMRON
 representative for details.

UL

UL508

E76675

CSA

CSA C22.2 No. 14

LR45746

CQC (CCC)

GB/T 14048.5

Consult your OMRON
 representative for details.

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T 14048.5)

Utilization category

AC-15

Rated operating current (Ie)

0.75 A

Rated operating voltage (Ue)

240 V

Note: Use a 10 A fuse type a gI or gG that conforms to IEC60269 as a short-circuit protection device. 

UL/CSA (UL508, CSA C22.2 No. 14) (A600)

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC
 240 VAC
 480 VAC
 600 VAC

10 A

60
 30
 15
 12

6
 3
 1.5
 1.2

7,200

720

Characteristics

Interlock type

Type 2 (EN ISO 14119)

Coding level

Low level coded (EN ISO 14119)

Degree of protection *1

IP67 (EN60947-5-1)

Durability *2

Mechanical

1,000,000 operations min.

Electrical

500,000 operations min. (10 A resistive load at 250 VAC)

Operating speed

0.1 m/s to 0.5 m/s

Operating frequency

30 operations/minute max.

Direct opening force *3

19.61 N min. (EN60947-5-1)

Direct opening travel *3

20 mm min. (EN60947-5-1)

Contact resistance

25 mΩ max.

Rated insulation voltage (Ui)

600 V (EN60947-5-1)

Rated frequency

50/60 Hz

Protection against electric shock

Class I (with ground terminal)

Pollution degree (operating environment)

3 (EN60947-5-1)

Impulse withstand
 voltage (Uimp)
 (EN60947-5-1)

Between terminals of same polarity

4 kV

Between terminals of different
 polarity

Between each terminal and ground

Insulation resistance

100 MΩ min. (at 500 VDC) between terminals of same or different
 polarity, between each terminal and ground, and between each
 terminal and non-current-carrying metal part

Contact gap

2 × 2 mm min.

Vibration resistance

Malfunction

10 to 55 Hz, 0.65 mm single amplitude

Shock resistance

Destruction

1,000 m/s2 min. (IEC68-2-27)

Malfunction

300 m/s2 min. (IEC68-2-27)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (Ithe)

20 A (EN60947-5-1)

Ambient operating temperature

-40 to 80°C (with no icing)

Ambient operating humidity

95% max.

Weight

Approx. 285 g (D4BS-15FS)

Note: The above values are initial values.
 *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
 *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.
 *3. These figures are minimum requirements for safe operation.