Product Category

Safety Door Switches

D4NS, D4NS-SK

Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
 • Low Voltage Directive
 • EN50047
 • EN60947-5-1
 • EN ISO 14119
 • GS-ET-15 

Certified Standards

Certification body

Standard

File No.

TÜV SÜD

EN60947-5-1
 (certified direct opening)

Consult your OMRON representative for details.

UL *1

UL508, CSA C22.2 No.14

E76675

CQC (CCC)

GB/T 14048.5

Consult your OMRON representative for details.

KOSHA *2

EN60947-5-1

Consult your OMRON representative for details.

*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
 *2. Only certain models have been certified. 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T 14048.5)

Utilization category

AC-15

DC-13

Rated operating current (Ie)

3 A

0.27 A

Rated operating voltage (Ue)

240 V

250 V

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
            into the Switch.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC

10 A

60

6

7,200

720

240 VAC

30

3

Q300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

125 VDC

2.5 A

0.55

0.55

69

69

250 VDC

0.27

0.27

Characteristics                                                     

Interlock type

Type 2 (EN ISO 14119)

Coding level

Low level coded (EN ISO 14119)

Degree of protection *1

IP67 (EN60947-5-1)

Durability *2

Mechanical

Standard type: 1,000,000 operations min.
 High pull-force type: 100,000 operations min.

Electrical

Standard type:
 500,000 operations min. (3 A resistive load at 250 VAC) *3
 300,000 operations min. (10 A resistive load at 250 VAC)
 High pull-force type:
 100,000 operations min. (10 A resistive load at 250 VAC)

Operating speed

0.05 to 0.5 m/s

Direct opening force *4

Standard type: 60 N min.
 High pull-force type: 80 N min.

Direct opening travel *4

10 mm min.

Contact resistance

25 mΩ max.

Minimum applicable load *5

1 mA resistive load at 5 VDC (N-level reference value)

Rated insulation voltage (Ui)

300 V

Rated frequency

50/60 Hz

Protection against electric shock

Class II (double insulation)  image

Pollution degree (operating environment)

3 (EN60947-5-1)

Impulse withstand
 voltage (Uimp)
 (EN60947-5-1)

Between terminals of same
 polarity

2.5 kV

Between terminals of different
 polarity

4 kV

Between each terminal and
 non-current carrying metallic
 parts

6 kV

Insulation resistance

100 MΩ min.

Contact gap

2 × 2 mm min.

Vibration resistance

Malfunction

10 to 55 Hz, 0.75 mm single amplitude

Shock resistance

Destruction

1,000 m/s2 min.

Malfunction

300 m/s2 min.

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional free air thermal current (Ith)

10 A (EN60947-5-1)

Ambient operating temperature

-30 to 70°C (with no icing)

Ambient operating humidity

95% max.

Weight

Approx. 96 g (D4NS-1CF)

Note: 1. The above values are initial values.
            2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
 *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
 *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.
 *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
 *4. These figures are minimum requirements for safe operation.
 *5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.