Product Category

All Metals and Long-distance Types

E2V-X[]

Aluminum and Iron Both Detectable from Long Distances

Ratings and Specifications

Size

M12

M18

M30

Model

E2V-X2[][]

E2V-X4[][]

E2V-X5[][]

E2V-X8[][]

E2V-X10[][]

E2V-X15[][]

Sensing distance

2 mm±10%

4 mm±10%

5 mm±10%

8 mm±10%

10 mm±10%

15 mm±10%

Set distance

0 to 1.6 mm

0 to 3.2 mm

0 to 4.0 mm

0 to 6.4 mm

0 to 8.0 mm

0 to 12.0 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metals and non-ferrous metals (The sensing distance depends on the material of
 the sensing object. Refer to Engineering Data (Reference value).)

Standard sensing object

Aluminum:
 12 × 12 ×
 3 mm

Aluminum:
 12 × 12 ×
 3 mm

Aluminum:
 18 × 18 ×
 3 mm

Aluminum:
 24 × 24 ×
 3 mm

Aluminum:
 30 × 30 ×
 3 mm

Aluminum:
 45 × 45 ×
 3 mm

Response frequency *

150 Hz

40 Hz

70 Hz

40 Hz

70 Hz

30 Hz

Power supply voltage
 (operating voltage range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Current consumption

450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)

Control
 output

Load current

Open-collector output, 100 mA max.

Residual
 voltage

2 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC
 Models: Operation indicator (yellow) (lit)

Operation mode

B1/C1 Models: NO
 B2/C2 Models: NC
 (Refer to the timing charts under I/O Circuit Diagrams for details.)

Protection circuits

Power supply reverse polarity protection, reversed output polarity protection, load short-
 circuit protection, surge suppressor

Ambient temperature

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

Based on the sensing distance at 23°C in the temperature range of -25 to 70°C

±10% max.

±15% max.

±10% max.

±15% max.

±10% max.

±15% max.

Voltage influence

±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the
 OMRON in-house standard.)

Connection method

Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector
 Models (Standard cable length: 300 mm)

Weight
 (packed
 state)

Cable

Approx. 120 g

Approx. 150 g

Approx. 200 g

Connector

Approx. 30 g

Approx. 45 g

Approx. 120 g

Pre-wired
 Connector
 Models

Approx. 50 g

Approx. 70 g

Approx. 140 g

Materials

Case

Nickel-plated brass

Sensing
 surface

Heat-resistant ABS

Clamping nuts

Nickel-plated brass

Toothed
 washer

Zinc-plated iron

Accessories

Instruction manual

* The response frequency is an average value. Measurement conditions are as follows: Standard sensing object, a distance between target objects of twice the size of the standard sensing object, and a set distance of half the sensing distance.