Product Category

Slim I/O Relay

G2RV-ST

Slim I/O relay realizes space saving thanks to high-density mounting and ultra-slim body

Model Number Structure
Model Number Legend
Ordering Information
Terminal
(Wire connection)
Classification
Latching lever
(Test switch)
Rated input
voltage (V)
Model
Push-In Plus Terminal
Standard
No
DC
12
G2RV-ST500 12 VDC
24
G2RV-ST500 24 VDC
AC/DC
24
G2RV-ST500 24 VAC/VDC
48
G2RV-ST500 48 VAC/VDC
AC
100
G2RV-ST500 100 VAC
110
G2RV-ST500 110 VAC
200
G2RV-ST500 200 VAC
230
G2RV-ST500 230 VAC
Yes
DC
24
G2RV-ST501 24 VDC
AC/DC
24
G2RV-ST501 24 VAC/VDC
Microloads
No
DC
12
G2RV-ST500-AP 12 VDC
24
G2RV-ST500-AP 24 VDC
AC/DC
24
G2RV-ST500-AP 24 VAC/VDC
48
G2RV-ST500-AP 48 VAC/VDC
AC
100
G2RV-ST500-AP 100 VAC
110
G2RV-ST500-AP 110 VAC
200
G2RV-ST500-AP 200 VAC
230
G2RV-ST500-AP 230 VAC
Screw terminal
Standard
No
DC
12
G2RV-ST700 12 VDC
24
G2RV-ST700 24 VDC
AC/DC
24
G2RV-ST700 24 VAC/VDC
48
G2RV-ST700 48 VAC/VDC
AC
100
G2RV-ST700 100 VAC
110
G2RV-ST700 110 VAC
200
G2RV-ST700 200 VAC
230
G2RV-ST700 230 VAC
Yes
DC
24
G2RV-ST701 24 VDC
AC/DC
24
G2RV-ST701 24 VAC/VDC
Microloads
No
DC
12
G2RV-ST700-AP 12 VDC
24
G2RV-ST700-AP 24 VDC
AC/DC
24
G2RV-ST700-AP 24 VAC/VDC
48
G2RV-ST700-AP 48 VAC/VDC
AC
100
G2RV-ST700-AP 100 VAC
110
G2RV-ST700-AP 110 VAC
200
G2RV-ST700-AP 200 VAC
230
G2RV-ST700-AP 230 VAC
Note: Sockets are not sold individually.
Relay for Maintenance
Model Number Legend
List of Models
Type
Latching Lever
(Test switch)
Rated coil
voltage (V)
Model
Applicable model
Standard
No
DC
11
G2RV-1-S-G DC11
G2RV-ST700/500 12 VDC
21
G2RV-1-S-G DC21
G2RV-ST700/500 24 VDC
G2RV-ST700/500 24 VAC/VDC
48
G2RV-1-S-G DC48
G2RV-ST700/500 48 VAC/VDC
G2RV-ST700/500 100 VAC
G2RV-ST700/500 110 VAC
G2RV-ST700/500 200 VAC
G2RV-ST700/500 230 VAC
Yes
DC
21
G2RV-1-SI-G DC21
G2RV-ST701/501 24 VDC
G2RV-ST701/501 24 VAC/VDC
Microload
No
DC
11
G2RV-1-S-AP-G DC11
G2RV-ST700/500-AP 12 VDC
21
G2RV-1-S-AP-G DC21
G2RV-ST700/500-AP 24 VDC
G2RV-ST700/500-AP 24 VAC/VDC
48
G2RV-1-S-AP-G DC48
G2RV-ST700/500-AP 48 VAC/VDC
G2RV-ST700/500-AP 100 VAC
G2RV-ST700/500-AP 110 VAC
G2RV-ST700/500-AP 200 VAC
G2RV-ST700/500-AP 230 VAC
Note: Voltage is reduced within the socket for the slim I/O relay, so the rated input voltage and rated coil voltage of replacement relays are different.
Accessories (order separately)
Short Bars
Appearance
Pitch
No. of
poles
Colors
Model *1
Minimum order
(Quantity)
Maximum energizing
current
6.2 mm
20
Red (R),
Blue (S),

Yellow (Y)
PYDN-6.2ST-200[]
10 *2
32 A
Note: Use for wiring to the adjacent socket.
*1. Replace the box ([]) in the model number with the code for the covering color. [] color selection: R = red, S = blue, Y = yellow

*2. Short bars come in bags of 10.
Label
Appearance
Model
Minimum order (Sheet)
(Pieces per sheet)
XW5Z-P2.5LB1
5
(1 sheet/72 pieces)
Separate Plate
Appearance
Model
XW5Z-EP12
Isolation plate
Appearance
Model
P2RV-P3.1ST
PLC interface unit
Appearance
I/O classification
Connection
method
Common
process
Applicable
Models *
Model
For input
Push-In
PNP
G2RV-ST500-AP
P2RVC-8ST-I-5-1
NPN
P2RVC-8ST-I-5
Screw
PNP
G2RV-ST700-AP
P2RVC-8ST-I-7-1
For output
Push-In
PNP
G2RV-ST500
G2RV-ST501

G3RV-ST500
P2RVC-8ST-O-5-1
NPN
P2RVC-8ST-O-5
Screw
PNP
G2RV-ST700
G2RV-ST701

G3RV-ST700
P2RVC-8ST-O-7-1
* Please make sure applicable models, P2RVC can not be used other combination than the above table.
Parts for DIN Track Mounting
Appearance
Type
Model
Minimum order
(Quantity)
DIN Tracks
1 m
PFP-100N
1
0.5 m
PFP-50N
End Plate *
PFP-M
10
Spacer
PFP-S
* When mounting DIN Track, please use End Plate (PFP-M).
Refer to your OMRON website for details on PFP-[].
Applicable Cables
Name
Appearance
Cable
length

L (mm)
Connecting Cables
Applicable Connectors
Cables with
Loose Wires

P2RV-A[]C
8 I/O
points
1,000
P2RV-A100C
Various devices
2,000
P2RV-A200C
3,000
P2RV-A300C
5,000
P2RV-A500C
OMRON PLC
Connecting

Cables with

Connectors (1:4)

P2RV-4-[]C
32 output
points
1,000
P2RV-4-100C
PLC I/O Units with MIL
connectors (1:4)

CJ1W-OD232/OD262, etc.
2,000
P2RV-4-200C
3,000
P2RV-4-300C
5,000
P2RV-4-500C
OMRON PLC
Connecting

Cables with
Connectors (1:4)

P2RV-4-[]IMC
32 input
points
1,000
P2RV-4-100IMC
PLC I/O Units with MIL
connectors (1:4)

CJ1W-ID232/ID262, etc. *1
2,000
P2RV-4-200IMC
3,000
P2RV-4-300IMC
5,000
P2RV-4-500IMC
OMRON PLC
Connecting

Cables with

Connectors (1:4)

P2RV-4-[]IFC
32 input
points
1,000
P2RV-4-100IFC
PLC I/O Units with Fujitsu/
Otax connectors (1:4)

CJ1W-ID231/ID261, etc. *2
2,000
P2RV-4-200IFC
3,000
P2RV-4-300IFC
5,000
P2RV-4-500IFC
OMRON PLC
Connecting

Cables with

Connectors (1:1)

P2RV-A[]C-OMR

NX
8 output
points
500
P2RV-A050C-OMR NX
PLC I/O Units with
screw-less clamp

terminal block (1:1)

For inputs: NX-ID4442

For outputs: NX-OD4256
1,000
P2RV-A100C-OMR NX
8 input
points
500
P2RV-A050IC-OMR NX
1,000
P2RV-A100IC-OMR NX
Schneider Electric
PLC Connecting

Cables

P2RV-[]C-SCH-[]
32 input
points
500
P2RV-050C-SCH-A
Schneider Electric PLCs with
32-point connectors (1:4)

For inputs: 140 DDI 353 00

For outputs: 140 DDO 353 00
1,000
P2RV-100C-SCH-A
2,000
P2RV-200C-SCH-A
3,000
P2RV-300C-SCH-A
5,000
P2RV-500C-SCH-A
32 output
points
500
P2RV-050C-SCH-B
1,000
P2RV-100C-SCH-B
2,000
P2RV-200C-SCH-B
3,000
P2RV-300C-SCH-B
5,000
P2RV-500C-SCH-B
16 input
points
500
P2RV-050C-SCH-C
Schneider Electric PLCs with
16-point connectors (1:2)

For inputs: BMX DDI 1602

For outputs: BMX DDO 1602
1,000
P2RV-100C-SCH-C
2,000
P2RV-200C-SCH-C
3,000
P2RV-300C-SCH-C
5,000
P2RV-500C-SCH-C
16 output
points
500
P2RV-050C-SCH-D
1,000
P2RV-100C-SCH-D
2,000
P2RV-200C-SCH-D
3,000
P2RV-300C-SCH-D
5,000
P2RV-500C-SCH-D
Siemens PLC
Connecting Cables

P2RV-[]C-SIM-[]
32 input
points
500
P2RV-050C-SIM-A
Siemens PLCs with
32-point connectors (1:4)

For inputs:

6ES7 321-1BL00-0AA0

For outputs:

6ES7 322-1BL00-0AA0
1,000
P2RV-100C-SIM-A
2,000
P2RV-200C-SIM-A
3,000
P2RV-300C-SIM-A
5,000
P2RV-500C-SIM-A
32 output
points
500
P2RV-050C-SIM-B
1,000
P2RV-100C-SIM-B
2,000
P2RV-200C-SIM-B
3,000
P2RV-300C-SIM-B
5,000
P2RV-500C-SIM-B
16 input
points
500
P2RV-050C-SIM-C
Siemens PLCs with
16-point connectors (1:2)

For inputs:

6ES7 321-1BH02-0AA0
1,000
P2RV-100C-SIM-C
2,000
P2RV-200C-SIM-C
3,000
P2RV-300C-SIM-C
5,000
P2RV-500C-SIM-C
32 input
points
500
P2RV-050C-SIM-D
Siemens PLCs with
32-point connectors (1:4)

For inputs:

6ES7 421-1BL-0AA0

For outputs:

6ES7 422-1BL-0AA0
1,000
P2RV-100C-SIM-D
2,000
P2RV-200C-SIM-D
3,000
P2RV-300C-SIM-D
5,000
P2RV-500C-SIM-D
32 output
points
500
P2RV-050C-SIM-E
1,000
P2RV-100C-SIM-E
2,000
P2RV-200C-SIM-E
3,000
P2RV-300C-SIM-E
5,000
P2RV-500C-SIM-E
*1. Use the P2RVC-8ST-I-[]-1(PNP) as the PLC interface unit when connecting to the CJ1W-ID232/ID262 (or a unit with an equivalent terminal arrangement).
*2. Use the P2RVC-8ST-I-[]-1(PNP) as the PLC interface unit when connecting to the CJ1W-ID231/ID261 (or a unit with an equivalent terminal arrangement).