Slim I/O Relay

G2RV-ST

Slim I/O relay realizes space saving thanks to high-density mounting and ultra-slim body

Ratings
Coil ratings
Rated input
voltage
Rated current
Must
operate

voltage
Must
release

voltage
Power consumption
Maximum
allowable

voltage
AC
DC
Percentage of the
rated voltage
AC (VA)
DC (mW)
Percentage
of the rated

voltage
50 Hz
60 Hz
12 VDC
-
-
27.9 mA
80% max.*
10% min.
-
Approx. 300 mW
110%
24 VDC
-
-
13.5 mA
-
Approx. 300 mW
24 VAC/VDC
13.7 mA
14.9 mA
12.6 mA
Approx. 0.4 VA
Approx. 300 mW
48 VAC/VDC
5.9 mA
6.4 mA
5.4 mA
Approx. 0.3 VA
Approx. 250 mW
100 VAC
6.8 mA
7.1 mA
-
Approx. 0.7 VA
-
110 VAC
6.1 mA
6.4 mA
-
Approx. 0.7 VA
-
200 VAC
6.1 mA
7.3 mA
-
Approx. 1.5 VA
-
230 VAC
6.8 mA
8.2 mA
-
Approx. 1.9 VA
-
Note: The operating characteristics are measured at ambient temperature of 23°C.
* Operating voltage will be, for mounting in the upside down direction, 85% max.

(Upside down: Direction in which the mechanical indicator faces down)
Contact ratings
Item
Standard
(G2RV-ST700, 500, 701, 501)
For microloads
(G2RV-ST700-AP, 500-AP) *2
Contact configuration
SPDT
Load
Resistive load
(cosφ=1)
Inductive load
(cosφ=0.4, L/R=7ms)
Resistive load
(cosφ=1)
Rated load
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current *3
6 A
50 mA
Maximum switching voltage
440 VAC, 125 VDC
30 VAC, 36 VDC
Maximum switching current
6 A
50 mA
Maximum switching power
1,500 VA
180 W
500 VA
60 W
-
Failure rate P value
(reference value) *1
10 mA at 5 VDC
1 mA at 100 mVDC
*1. P level: λ60=0.1×10-6/times
  This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.

*3. Please energize under 32A total when use short bar connection.
Characteristics
Item
Standard
(G2RV-ST700, 500, 701, 501)
For microloads
(G2RV-ST700-AP, 500-AP)
Contact resistance *
100 mΩ max.
Operate time *
20 ms max.
Release time *
AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: Energized 200m/s
2, Non-energized 100m/s2
Endurance *
Mechanical
5,000,000 operations min.
Electrical
NO contact: 70,000 operations min.
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating
temperature
Operating: -40 to +55°C (with no icing or condensation)
Ambient operating
humidity
Operating: 5 to 85% RH
Weight
Approx. 30 g
Type of interruption
Micro-disconnection
Type of insulation
Basic isolation: Coil-Contact, Live parts-Ground
Pollution degree
2
Impulse withstand
voltage
4.0 kV
Test procedure
A (Group mounting)
Categories of
environmental protection
RT 1
Degree of protection by
enclosure according to

IEC 60529
IP20
Contact material
Ag alloy
Ag alloy + Au plating
Note: Above values are initial values.
* Value is at ambient temperature of 23°C.
Approved standards
UL (File No.E41515)
Model
Contact form
Operation coil ratings
Contact ratings
Operations
G2RV-ST series
SPDT
12 to 48 VDC
24 to 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)

2 A at 400 VAC (Resistive load)*
6,000
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12) or 4psc of isolation plate (P2RV-P3.1T).
TÜV (File No.R50559210, EN61810-1)
Model
Contact form
Operation coil ratings
Contact ratings
Operations
G2RV-ST series
SPDT
12, 24 VDC
24, 48 VAC/VDC

100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)

2 A at 400 VAC (Resistive load)*
50,000
50,000

6,000
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12) or 4psc of isolation plate (P2RV-P3.1T).
Lloyd’s (File No.LR23158192TA)
Model
No. of poles
Operation coil ratings
Contact ratings
G2RV-ST500
G2RV-ST700
1c
12, 24 VDC
24, 48 VAC/VDC

100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)

6 A at 30 VDC (Resistive load)

2 A at 30 VDC (L/R=7 ms)
G2RV-ST501
G2RV-ST701
1c
12, 24 VDC
24 VAC/VDC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)

6 A at 30 VDC (Resistive load)

2 A at 30 VDC (L/R=7 ms)
G2RV-ST500-AP
G2RV-ST700-AP
1c
12, 24 VDC
24, 48 VAC/VDC

100, 110, 200, 230 VAC
0.05 A at 30 VAC (Resistive load)
0.05 A at 36 VDC (Resistive load)
PLC interface unit
Ratings / characteristices
Rated voltage
30 VAC/DC
Rated current
0.5 A/poles, 2 A/unit
Ambient operating temperature
-40 to 55°C
Vibration resistance
Destruction
10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction
10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance
Destruction
300 m/s2
Malfunction
100 m/s2