General-purpose Relay
G7T
Slim-styled I/O Relay Saves Space in Panel
When your order, specify the rated voltage.
Classification | Model | Rated voltage | |
Input (bifurcated contact) | SPST-NO | G7T-1122S (see note 2) | 12 VDC |
24 VDC | |||
100/110 VAC | |||
200/220 VAC | |||
Output (single contact) | SPST-NO | G7T-1112S (see note 2) | 12 VDC |
24 VDC | |||
SPST-NC | G7T-1012S | 12 VDC | |
24 VDC | |||
SPDT | G7T-112S | 12 VDC | |
24 VDC |
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in
Specifications.
Specifications.
2. The G7T-1122S and G7T-1112S are approved by UL and CSA. Contact your OMRON representative for the coil ratings of other models. The G7T-112S cannot be used in place of the G7TC. The G7T-112S can only be used with the P7TF-05 Socket.
3. "Input" and "output" indicate the I/O relationship to a PLC. Input Relays are mainly suitable for input signals to a PLC or other device. Output Relays are mainly suitable to switching loads that receive output signals from a
PLC or other device. The Input and Output Relays have different switching performances. Select a suitable Relay for the application.
3. "Input" and "output" indicate the I/O relationship to a PLC. Input Relays are mainly suitable for input signals to a PLC or other device. Output Relays are mainly suitable to switching loads that receive output signals from a
PLC or other device. The Input and Output Relays have different switching performances. Select a suitable Relay for the application.
Accessories
Socket
Applicable Relay | Model |
All G7T I/O Relay and the G3TA models. | P7TF-05 |
P70 Indicator Module
Remove the transparent style strip of the Socket and mount this module. It will function as an operation indicator with surge suppression.
Model | Applicable Relay coil voltage | Remarks | |
For AC Relay | P70A | 100/110 VAC | Surge suppressing system with varistor |
200/220 VAC | |||
For DC Relay | P70D | 12/24 VDC | Surge suppressing system with diode |
Note: 1. Order the Indicator Module that is suited to the Relay coil voltage.
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. Input current (reference values):
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. Input current (reference values):
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA