Magnetic Proximity Sensor
GLS
Easy-to-use, Simple Magnetic Proximity Sensor
| 
                     Model  | 
                
                     GLS-1  | 
                
                     GLS-1L  | 
            |
| 
                     Sensing distance  | 
                
                     15 mm *1  | 
            ||
| 
                     Contact circuit  | 
                
                     SPST-NO  | 
            ||
| 
                     Switching capacity *2  | 
                
                     Maximum operating voltage: 100 VDC   | 
            ||
| 
                     Contact dielectric strength  | 
                
                     250 VDC for 1 min with a leakage current of 1 mA max.  | 
            ||
| 
                     Response frequency  | 
                
                     20 Hz max.  | 
            ||
| 
                     Ambient temperature range  | 
                
                     Operating/Storage: -20 to 60°C (with no icing or condensation)  | 
            ||
| 
                     Ambient humidity range  | 
                
                     Operating/storage: 35% to 85% (with no condensation)  | 
            ||
| 
                     Contact resistance  | 
                
                     150 mΩ max.  | 
                
                     250 mW max. (including conductor resistance of lead wire)  | 
            |
| 
                     Dielectric strength  | 
                
                     1,000 VAC for 1 min between terminals and case  | 
            ||
| 
                     Life expectancy  | 
                
                     50,000,000 times min. with 0.1-A resistive load at 24 VDC  | 
            ||
| 
                     Vibration resistance  | 
                
                     Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  | 
            ||
| 
                     Shock resistance  | 
                
                     Destruction: 300 m/s2 3 times each in X, Y, and Z directions  | 
            ||
| 
                     Degree of protection  | 
                
                     IP40 (IEC)  | 
                
                     IP62 (IEC)  | 
            |
| 
                     Connection method  | 
                
                     Terminal block  | 
                
                     Pre-wired (standard cable length: 1 m)  | 
            |
| 
                     Materials  | 
                
                     Sensor  | 
                
                     ABS  | 
            |
| 
                     Magnet  | 
            |||