Level measurement
Endress+Hauser Level measurement is one of the world’s leading providers of measuring instruments and complete systems for Level measurementt.
Products List

Conductive Point level detection Liquipoint FTW32
Rope probe for multipoint detection for up to 5 switch points
Predecessor: One rode probe 11263, 21373, FTW131
- Process temperature: -40 °C … 70 °C
(-40 °F … 158 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Min. conductivity of medium: 10 µS/cm

Servo tank gauging instrument Proservo NMS80
High precision servo measurement for liquid level, interface and density
Predecessor: Proservo NMS5
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C
(-328°F…392°F) - Process pressure / max. overpressure limit: 0,2…6 bar abs
- Max. measurement distance: 36 m (118 ft)
- Main wetted parts: 316L, AlloyC276, PTFE

Servo tank gauging instrument Proservo NMS81
High precision servo measurement for liquid level, interface and density
Predecessor: Proservo NMS5
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C, (-328°F…392°F)
- Process pressure / max. overpressure limit: up to 25 bar (363 psi) abs
- Max. measurement distance: 47 m (154 ft)
- Main wetted parts: 316L, AlloyC276, PTFE

Radiometric measurement Gamma Modulator FHG65
Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50

Capacitance Level measurement Liquicap FMI21
For continuous level measurement in conductive liquids
Predecessor: T6667, Double rod probe 11304Z
- Accuracy: < 1%
- Process temperature: -40 °C … 100 °C
(-40 °F … 212 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Max. measurement distance: 2.5 m (8 ft)
- Main wetted parts: Probe rods:, 316L/1.4404 / PP, Option: carbon fibre PP coated

Capacitance Level measurement Liquicap FMI52
For continuous level and interface measurement in liquids – for large measuring ranges
Predecessor: Silometer FMC420, Float Gauge LTC2230, T6667, Multicap DC21, DC26, Double rod probe 11304Z, Multicap T DC21TEN, DC26TEN, Multicap DC21AN, Multicap DC21EN, DC26AN, DC26EN, Multicap DC21AS, Multicap DC21ES, DC26AS, DC26ES, Multicap T DC21TAS, DC26TAS, Multicap T DC21TAN, DC26TAN, Multicap T DC21TES, DC26TES
- Accuracy: repeatablity 0,1%
- Process temperature: -80°C…200°C
-112°F…392°F - Process pressure / max. overpressure limit: Vacuum … 100 bar
(Vaccum … 1450 psi) - Max. measurement distance: 0.42 m … 10.0 m
(1.38 ft … 33 ft) - Main wetted parts: Insulation material: FEP,PFA, 316L

Electromechanical Level measurement Silopilot FMM20
Basic model for continuous level measurement in light bulk solids
- Accuracy: +/- 2.5 cm (0.98″)
- Process temperature: -20°C … +150°C
(-4°F…302°F) - Process pressure / max. overpressure limit: 0.8 … 1.1 bar abs.
(11.6psi …15.95psi abs.) - Max. measurement distance: 32m (105ft)
- Main wetted parts: Aluminium, Steel, Stainless steel

Electromechanical Level measurement Silopilot FMM50
For continuous level measurement even in high bulk solids silos or bins
Predecessor: Silopilot FMM760, FMM760Z
- Accuracy: +/- 5 cm
- Process temperature: -20°C … +230°C
(-4°F … 446°F) - Process pressure / max. overpressure limit: 0.8 … 3 bar abs.
(11.6psi …43.5psi abs.) - Max. measurement distance: 70m (230ft)
- Main wetted parts: Aluminium, Steel, Stainless steel

Radar measurement Time-of-Flight Micropilot FMR50
Basic model for level liquid applications
Predecessor: Micropilot M FMR244
- Accuracy: +/- 2 mm (0.08 in)
- Process temperature: -40…+130 °C
(-40…+266 °F) - Process pressure / max. overpressure limit: Vacuum…3 bar
(Vacuum…43.5 psi) - Max. measurement distance: Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft) - Main wetted parts: PVDF, Viton, PP, PBT

Radar measurement Time-of-Flight Micropilot FMR56
Economically efficient basis model for level measurement in solids
Predecessor: Micropilot M FMR244, Prosonic S FDU96
- Accuracy: +/- 3 mm (0.12 in)
- Process temperature: -40 °C…+80 °C
(-40 °F…+176 °F) - Process pressure / max. overpressure limit: Vacuum…3 bar
(Vacuum…43.5 psi) - Max. measurement distance: 30 m (98 ft)
- Main wetted parts: PP, UP

Radar measurement Micropilot FMR60
The standard sensor for highest demands in liquid level measurement with 80GHz technology
- Accuracy: +/- 1 mm (0.04 in)
- Process temperature: -40…+130 °C
(-40…+266 °F) - Process pressure / max. overpressure limit: Vacuum …16 bar
(Vacuum … 232 psi) - Max. measurement distance: 50 m (164 ft)
- Main wetted parts
- PTFE antenna: PP or 316L process connections

Radar measurement Micropilot FMR62
For 80GHz level measurement in aggressive liquids or applications with hygiene requirements
- Accuracy: +/- 1 mm (0.04 in)
- Process temperature: -40…+200 °C
(-40…+392 °F) - Process pressure / max. overpressure limit: Vacuum…+25 bar
(Vacuum…+362.6 psi) - Max. measurement distance: 80 m (262 ft)
- Main wetted parts: PTFE or PEEK antenna, 316L threads, PTFE cladded flanges

Radar measurement Micropilot FMR67
The standard sensor for highest demands in bulk solids level measurement with 80GHz technology
- Accuracy: +/- 3 mm (0.12 in)
- Process temperature: -40…+200 °C
(-40…+392 °F) - Max. measurement distance: 125 m (410 ft)
- Main wetted parts: PTFE, 316L, Alignment device: Alu

Hydrostatic Level measurement Waterpilot FMX11
Simple and reliable level probe for freshwater applications
- Accuracy: pn ≥ 400mbar: 0.35 %
pn < 400mbar: 0.50 % - Process temperature: -10°C…+70°C
(+14°F…+158°F) - Pressure measuring range: 200 mbar…2 bar
(3 psi…29 psi) - Process pressure / max. overpressure limit: 10 bar (145 psi)
- Main wetted parts: 316L
- Max. measurement distance: 20 m H2O
(66 ft H2O) - Material process membrane: Metal
- Measuring cell: 200 mbar…2 bar, (3 psi…29 psi)

Hydrostatic Level measurement Waterpilot FMX21
Reliable and robust level probe with ceramic measuring cell and HART
Predecessor: Waterpilot FMX167
- Accuracy: 0.2%
0.1% (optional) - Process temperature: -10°C…70°C
(14°F…158°F)
Diameter 29 mm (1.14″): 0°C…50°C
(32°F…122°F) - Pressure measuring range: 100 mbar…20 bar
(1.5 psi…300 psi) - Main wetted parts: Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
Extension cable: PE, PUR, FEP - Max. measurement distance: 200 m H2O
(656 ft H2O) - Measuring cell: 100mbar…20bar, (1.5psi…300psi)

Radiometric Level and density Source Container FQG66
Radiation source container with sliding source support rod for manual or pneumatic on/off switching
Predecessor: Source container QG2000
- Process temperature: Any
- Process pressure / max. overpressure limi: Any
- Main wetted parts: Non-contact

Microwave barrier transmitter Soliwave FQR56
Transmitterfor non-contact point level detection in bulk solids
- Process temperature: Non-contact installation: any
Within installation:
-40 °C…+70 °C (-40 °F…+158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) - Process pressure / max. overpressure limit: Non-contact installation: any, Within installation: 0.5 bar…6.8 bar (7.2 psi…99 psi) abs. With HD-Adapter: up to +21 bar (+305 psi) abs., Min. density of medium, Solid weight: > 10 g/l

Capacitance Point level detection Minicap FTC260
Designed for light bulk solids
Predecessor: FTC731, FTC730
- Process temperature: -40 °C … 120°C
(-40 °F … 248 °F)
Process pressure / max. overpressure limit: -1 … 25 bar, (-14.5 … 360 psi)

Capacitance Point level detection Minicap FTC262
Designed for light bulk solids
Predecessor: FTC831, FTC830
- Process temperature: -40 °C … 80 °C
- (-40 °F … 176 °F)
Process pressure / max. overpressure limit: -1 … 6 bar(-14.5 … 90 psi)

Point level switch Soliswitch FTE30 rotary paddle switch
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Predecessor: FTE130, FTE330
Successor: Soliswitch FTE20
- Process temperature: -20 °C … 80 °C (-4 °F … 170 °F)
Process pressure / max. overpressure limit: 0.5 bar to 1.5 bar (7 psi to 22 psi) - Min. density of medium: >= 100 g/l

Point level switch Soliswitch FTE31 Rotary paddle switch
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Successor: Soliswitch FTE20
- Process temperature: -20 °C … 80 °C (-4 °F … 170 °F)
- Process pressure / max. overpressure limit: 0.5 bar to 1.5 bar (7 psi to 22 psi)
- Min. density of medium: >= 100 g/l

Capacitance Point level detection Nivector FTI26
For all types of powdered and fine-grained solids especially in the food industry
- Process temperature: -40°C…80°C, (-40°F…176°F)

Vibronic Point level detection Liquiphant FTL50H
Compact vibration point level switch for liquids especially in the food and life sciences industry
Predecessor: CS1103, CS1113, CS1203, CS1213, CS1603, CS1613, Liquiphant FTL330H, Liquiphant FTL330L
- Process temperature: -50 °C…+150 °C
(-58 °F…+302 °F) - Process pressure / max. overpressure limit: Vacuum…64 bar
(Vacuum…928 psi) - Min. density of medium: 0.5g/cm³(0.4g/cm³ optional)

Vibronic Point level detection Liquiphant FTL51H
Point level switch with extension tube for liquids especially in the food and life sciences industry
Predecessor: CS1103, CS1113, CS1203, CS1213, CS1603, CS1613, Liquiphant FTL330H, Liquiphant FTL330L, FTL360, FTL361, FDL30, FDL31, FTL365, FTL366, FDL35, FDL36
- Process temperature: -50 °C…+150 °C
(-58 °F…+302 °F) - Process pressure / max. overpressure limit: Vacuum…64 bar
(Vacuum…928 psi) - Min. density of medium: 0.5g/cm³ (0.4g/cm³ optional)

Vibronic Point level detection Nivotester FailSafe FTL825
Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85

Servo tank gauging instrument Proservo NMS83
High precision servo measurement for liquid level, interface and density for hygienic applications
Predecessor: Proservo NMS7
- Accuracy: up to 0.4 mm
- Process temperature: -200°C…200°C
(-328°F…392°F) - Process pressure / max. overpressure limit: 6 bar abs
- Max. measurement distance: 22 m (72 ft)
- Main wetted parts: 316L, AlloyC276, PTFE

Float switch Liquifloat FTS20
For point level detection in liquids

Conductive Point level detection Double rod probe 11362Z
High resistant probes for corrosive liquids in plastic vessels
Predecessor: 11362
- Process temperature: -40 °C … 150 °C
(-40 °F … 302 °F) - Process pressure / max. overpressure limit: Vacuum … 30 bar
(Vacuum … 435 psi) - Min. conductivity of medium: 20 µS/cm

Conductive Point level detection Triple rod probe 11363Z
High resistant probes for corrosive liquids in plastic vessels
Predecessor: 11363
- Process temperature: -40 °C … 150 °C
(-40 °F … 302 °F) - Process pressure / max. overpressure limit: Vacuum … 30 bar
(Vacuum … 435 psi) - Min. conductivity of medium: 20 µS/cm

Conductive Point level detection One rod probe 11371
Point level detection of conductive liquids in the food industry
Predecessor: ST11370, 11370
- Process temperature: -10 °C … 100 °C
(+10 °F … +210 °F) - Process pressure / max. overpressure limit: Vacuum … 10 bar
(Vacuum … 145 psi) - Min. conductivity of medium: 20 µS/cm