Enclosed Switch
SHL
Subminiature Enclosed Switch (Measuring 48 x 17.5 x 45 mm) with High Sealing Property
Approved Standards
Agency |
Standard |
File No. |
Approved models |
UL |
UL508 |
E76675 |
General-purpose models listed on Data Sheet. |
CSA |
CSA C22.2 No. 14 |
LR45746 |
|
TÜV Rheinland |
EN60947-5-1 |
J50062486 |
All SHL models listed in this datasheet. |
CCC (CQC) |
GB/T14048.5 |
Contact your OMRON |
Ask your OMRON representative for information |
Ratings
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
|
|||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|
||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
||
125 VAC |
10 |
1.5 |
3 |
2.5 |
|
|||||
8 VDC |
10 |
2 |
5 |
2 |
|
|||||
Inrush current |
NC |
15 A max. |
||||||||
NO |
15 A max. |
|||||||||
|
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Micro load models
Rated voltage |
Non-inductive load (A) |
|
Resistive load |
||
NC |
NO |
|
125 VAC |
0.1 |
|
8 VDC |
0.1 |
Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T14048.5)
Model |
Category and rating |
I the |
SHL-[]55 |
AC-15 2 A/125 V |
5 A |
SHL-[]55-01 |
AC-14 0.1 A/125 V |
0.5 A |
SHL-[]55-L |
AC-15 2 A/125 V |
5 A |
SHL-[]55-01L |
AC-14 0.1 A/125 V |
0.5 A |
SHL-[]55-01L2 |
DC-12 0.1 A/12 V |
0.5 A |
SHL-[]55-L3 |
DC-12 2 A/24 V |
5 A |
SHL-[]55-01L3 |
DC-12 0.1 A/24 V |
0.5 A |
SHL-[]55-L4 |
DC-12 2 A/24 V |
5 A |
SHL-[]55-01L4 |
DC-12 0.1 A/24 V |
0.5 A |
SHL-[]55-L5 |
DC-12 2 A/48 V |
5 A |
SHL-[]55-01L5 |
DC-12 0.1 A/48 V |
0.5 A |
Note: "AC-15 2 A/125 V" indicates the following.
Application category: AC-16
Rated operating current (Ie): 2 A
Rated operating voltage (Ue): 125 V
UL/CSA
A300
Rated voltage |
Carry current |
Current (A) |
Volt-amperes (V) |
||
Make |
Break |
Make |
Break |
||
120 VAC |
10 A |
60 |
6 |
7,200 |
720 |
Characteristics (For SHL-W155)
Degree of protections *1 |
IP67 (EN60947-5-1) |
|
Durability *2 |
Mechanical |
10,000,000 operations min. |
Electrical |
500,000 operations min. |
|
Operating speed |
0.1 mm/s to 0.5 m/s (hinge lever models) |
|
Operating |
Mechanical |
120 operations/min |
Electrical |
30 operations/min |
|
Rated frequency |
50/60 Hz |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact resistance |
15 mΩ max. (initial value for the built-in switch when tested alone) |
|
Dielectric |
Between terminals of the same |
1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and |
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) |
|
Rated insulation voltage (Ui) |
150 V (EN60947-5-1) |
|
Pollution degree (operating environment) |
3 (EN60947-5-1) |
|
Short-circuit protective device (SCPD) |
10 A fuse type gI or gG (IEC60269) |
|
Conditional short-circuit current |
100 A (EN60947-5-1) |
|
Conventional enclosed thermal current (Ithe) |
5 A (EN60947-5-1) |
|
Protection against electric shock |
Class II (grounding not required with double insulation) |
|
OFF reverse voltage |
1,000 VAC max., 300 VDC max. (EN60947-5-1) |
|
Vibration |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude |
Shock |
Destruction |
1,000 m/s2 max. |
Malfunction |
300 m/s2 max. |
|
Ambient operating temperature |
-10°C to +80°C (with no icing) |
|
Ambient operating humidity |
35% to 95%RH |
|
Weight *3 |
Approx. 62 to 72 g |
Note: 1. The figures at the left are initial values.
2. The ratings at the left may vary depending on the model. Contact your OMRON representative for further details.
1. The head section of the plunger type SHL-D(Q)[][] is excluded.
2. Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
3. The values are for the plunger-type models.