Enclosed Switch
ZC-[]55
Small, High-precision Enclosed Switch
Model Number Structure
Model Number Legend
Ordering Information
Actuator |
Model |
Approved Standards |
|||
UL |
CSA |
EN |
|||
Plunger |
|
ZC-D55 |
● |
● |
● |
Panel mount plunger |
|
ZC-Q55 |
● |
● |
● |
Panel mount roller plunger |
|
ZC-Q2255 |
● |
● |
● |
Panel mount crossroller plunger |
|
ZC-Q2155 |
● |
● |
● |
Sealed roller plunger |
|
ZC-N2255 |
● |
● |
● |
Sealed crossroller plunger |
|
ZC-N2155 |
● |
● |
● |
Short hinge lever |
|
ZC-W55 |
● |
● |
● |
Hinge lever |
|
ZC-W155 |
● |
● |
● |
Short hinge roller lever |
|
ZC-W255 |
● |
● |
● |
Hinge roller lever |
|
ZC-W2155 |
● |
● |
● |
One-way action short hinge roller lever |
|
ZC-W355 |
● |
● |
● |
One-way action hinge roller lever |
|
ZC-W3155 |
● |
● |
● |
Note: 1. Use molded terminal models when using the Switch under one of the following conditions: a) dusty, b) high amount of dripping oil, or c) high humidity. Refer to Molded Terminal Model for the details.
2. Models are available with lead outlets in three positions: right-hand, left-hand, and underside.
Molded Terminal Model
Use of the molded terminal model is recommended in locations subject to excessive dust, oil drips, or moisture. The molded terminal model will have the same dimensions and operating characteristics as the basic model in each. Not approved by UL, CSA or EN.
Actuator |
Location of |
Left-hand |
Right-hand |
Underside |
Length |
||||
Plunger |
1 M |
ZC-D55-ML VCT 1M |
ZC-D55-MR VCT 1M |
ZC-D55-MD VCT 1M |
3 M |
ZC-D55-ML VCT 3M |
ZC-D55-MR VCT 3M |
ZC-D55-MD VCT 3M |
|
Panel mount |
1 M |
ZC-Q55-ML VCT 1M |
ZC-Q55-MR VCT 1M |
ZC-Q55-MD VCT 1M |
3 M |
ZC-Q55-ML VCT 3M |
ZC-Q55-MR VCT 3M |
- |
|
Panel mount |
1 M |
ZC-Q2255-ML VCT 1M |
ZC-Q2255-MR VCT 1M |
ZC-Q2255-MD VCT 1M |
3 M |
ZC-Q2255-ML VCT 3M |
ZC-Q2255-MR VCT 3M |
ZC-Q2255-MD VCT 3M |
|
Panel mount |
1 M |
ZC-Q2155-ML VCT 1M |
ZC-Q2155-MR VCT 1M |
ZC-Q2155-MD VCT 1M |
3 M |
- |
ZC-Q2155-MR VCT 3M |
ZC-Q2155-MD VCT 3M |
|
Sealed roller |
1 M |
ZC-N2255-ML VCT 1M |
ZC-N2255-MR VCT 1M |
ZC-N2255-MD VCT 1M |
3 M |
ZC-N2255-ML VCT 3M |
ZC-N2255-MR VCT 3M |
ZC-N2255-MD VCT 3M |
|
Sealed |
1 M |
ZC-N2155-ML VCT 1M |
ZC-N2155-MR VCT 1M |
ZC-N2155-MD VCT 1M |
3 M |
ZC-N2155-ML VCT 3M |
ZC-N2155-MR VCT 3M |
- |
|
Short hinge |
1 M |
- |
ZC-W55-MR VCT 1M |
- |
Hinge lever |
1 M |
ZC-W155-ML VCT 1M |
ZC-W155-MR VCT 1M |
ZC-W155-MD VCT 1M |
Short hinge |
1 M |
ZC-W255-ML VCT 1M |
ZC-W255-MR VCT 1M |
ZC-W255-MD VCT 1M |
Hinge roller |
1 M |
ZC-W2155-ML VCT 1M |
ZC-W2155-MR VCT 1M |
ZC-W2155-MD VCT 1M |
One-way |
1 M |
- |
ZC-W355-MR VCT 1M |
- |
Location of lead output
Right-hand |
MR |
Left-hand |
ML |
Underside |
MD |
Lead Supplies
Leads |
Nominal |
External diameter |
Terminal connections |
V.C.T. |
1.25 |
3 conductor: |
Black: COM |
Operation Indicator-equipped Models
Some models can be equipped upon request with a operation indicator to facilitate maintenance and inspection. Because the indicator is incorporated in the Terminal Protective Cover, the dimensions of the Limit Switch are not affected. In this model, the lead wire is to be connected to the screw terminal. (A connecting washer is provided on the tip of the lead wire). The lead wire can be connected to either the NC or NO terminal.
Operating characteristics are the same as the basic model from in each. Not approved by UL, CSA and EN.
* 12/24 VDC products are not subject to EN standards because their voltage is below that subject to CE marking regulations.
Actuator |
AC |
DC (12VDC) * |
DC (24VDC) * |
Plunger |
ZC-D55-L |
- |
ZC-D55-L4 |
Panel mount plunger |
ZC-Q55-L |
- |
ZC-Q55-L4 |
Panel mount roller plunger |
ZC-Q2255-L |
ZC-Q2255-L2 |
ZC-Q2255-L4 |
Panel mount crossroller plunger |
ZC-Q2155-L |
- |
ZC-Q2155-L4 |
Sealed roller plunger |
ZC-N2255-L |
ZC-N2255-L2 |
ZC-N2255-L4 |
Sealed crossroller plunger |
ZC-N2155-L |
ZC-N2155-L2 |
ZC-N2155-L4 |
Hinge lever |
ZC-W155-L |
- |
ZC-W155-L4 |
Short hinge roller lever |
ZC-W255-L |
- |
ZC-W255-L4 |
Hinge roller lever |
ZC-W2155-L |
- |
ZC-W2155-L4 |
(For AC)
• The operating voltage range is from 90 to 250 VAC.
• The dimensions are the same as the standard type. The top of the Terminal Protective Cover is transparent to allow checking the operation easily.
(For DC)
• The DC-operated is provided with an LED indicator.
• There is no protective structure.
• Since a rectifier stack is incorporated into the unit to permit reversing the polarity, this type can also operate on AC power source.
• The LED projects from the housing for easy visibility.
Accessories
MODEL |
|
ZC Terminal Cover |
TERMINAL COVER FOR ZC55 |
ZC Seal Rubber |
SC-R40 |
ZC Rubber Packing |
ZC RUBBER PACKING |
Note: The Switch is equipped with these 3 items as a standard.