Product Category

Enclosed Switch

ZC-[]55

Small, High-precision Enclosed Switch

Approved Standards

Agency

Standard

File No.

UL*

UL508

E76675

TÜV Rheinland

EN60947-1, EN60947-5-1

J50041904

CCC(CQC)

GB/T14048.5

Contact your OMRON representative for details.

Note: Ask your OMRON representative for information on approved models.
 * UL certified for CSA C22.2 No. 14. 

Ratings

Rated voltage

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
 250 VAC

10
 10

3
 2.5

1.5
 1.25

10
 10

5
 3

2.5
 1.5

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

10
 10
 6
 0.5
 0.25

3
 3
 3
 0.4
 0.2

1.5
 1.5
 1.5
 0.4
 0.2

6
 6
 5
 0.05
 0.03

5
 5
 5
 0.05
 0.03

2.5
 2.5
 2.5
 0.05
 0.03

Inrush current

NC

30 A max.

NO

15 A max.











Note: 1. The above figures are for steady-state currents.
          2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
          3. Lamp load has an inrush current of 10 times the steady-state current.
          4. Motor load has an inrush current of 6 times the steady-state current.
          5. The above ratings were tested under the following conditions according.
               (1) Ambient temperature:+20±2°C
               (2) Ambient humidity: 65±5%RH
               (3) Operating frequency:20 operations/min.

Approved Standard Ratings

UL/CSA

A300

Voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC
 240 VAC

10A

60
 30

6
 3

7,200

720

TÜV Rheinland (EN60947-1, EN60947-5-1), CCC (GB/T14048.5)

Applicable category and ratings

AC-12 10 A/250 VAC

Characteristics

Degree of protections

IP67

Durability

Mechanical

10,000,000 operations min.

Electrical

500,000 operations min.

Operating speed

0.05 mm/s to 0.5 m/s *1

Operating
 frequency

Mechanical

120 operations/min

Electrical

20 operations/min

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

15 mΩ max. (initial value for the builtin switch when tested alone)

Dielectric
 strength

Between non-continuous terminals

1,000 VAC, 50/60 Hz for 1 min

Between each terminal and non-
 current-carrying metal parts

2,000 VAC, 50/60 Hz for 1 min

Rated insulation voltage (Ui)

1,000 VAC

Pollution degree (operating environment)

3 (IEC947-5-1)

Short-circuit protective device

10 A-fuse type gG (IEC 60269)

Protection against electric shock

Class II

Proof tracking index (PTI)

175

Switch category

D (IEC335)

Rated operating current (Ie)

10 A

Rated operating voltage (Ue)

250 VAC

Vibration
 resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *2

Shock
 resistance

Destruction

1,000 m/s2 max.

Malfunction

300 m/s2 max. (in case of plunger model) *1 *2

Ambient operating temperature

-10°C to +80°C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight

Approx. 92 g (in case of ZC-Q22(21)55)

1. Only for models with plungers. (Contact your OMRON representative for information on other models.)
 2. Less than 1 ms under a free state at the operating limits.