Enabling Switch
A4E
3-position Enabling Switch for Safer Robot Operation
Certified Standards
Certification body | Standard | File No. |
UL * | UL508 CSA C22.2 No.14 | E76675 |
TÜV SÜD | EN60947 5-1 (certified direct opening) EN60947-5-8 | Consult your OMRON representative for details. |
CQC (CCC) | GB/T 14048.5 | 2003010305070634 |
* Certification for CSA C22.2 No. 14 by UL has been obtained.
Certified Standard Ratings TÜV (EN60947-5-1)
Utilization category | AC-15 | DC-13 |
Rated operating current (Ie) | 0.75 A | 0.55 A |
Rated operating voltage (Ue) | 240 V | 125 V |
UL/CSA (UL508, CSA C22.2 No.14),
CCC (GB/T 14048.5)
CCC (GB/T 14048.5)
300 mA at 24 VDC (Inductive load)
1 A at 125 VAC (Resistive load)
1 A at 125 VAC (Resistive load)
Ratings
Rated insulation voltage | 250 V |
Rated ON current | 2.5 A |
Rated load | 24 VDC, 300 mA (inductive load) 125 VAC, 1 A (resistive load) |
Minimum applicable load | 24 VDC, 4 mA |
Impulse withstand voltage | 4.0 kV between terminals of different polarity, 2.5 kV between terminals of same polarity |
Ambient operating temperature | -10 to 55°C (with no icing) |
Ambient operating humidity | 35% to 85% (with no condensation) |
Ambient storage temperature | -25 to 65°C |
Characteristics
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Contact resistance | 100 mΩ max. (initial value) |
Vibration resistance | 10 to 55 Hz, 0.75-mm single amplitude min. |
Shock resistance | 150 m/s2 |
Mechanical durability | OFF-ON: 1,000,000 operations min. OFF-ON-OFF (direct opening): 100,000 operations min. |
Electrical durability | 100,000 operations min. |
Degree of protection | IP65 (rubber seal type only) |