Safety I/O Unit
Safety Input Units
Unit
type
Ap-
pear-

ance
Specification
Unit
version
Model
Number
of

safety

input

points
Number
of

test

output

points
Internal
I/O

common
Rated
input

voltage
OMRON
special

safety

input

devices

*1
Number
of

safety

slave

con-

nections
I/O re-
freshing
method
Safety
Input

Units
4 points
2 points
Sinking
inputs

(PNP)
24 VDC
Can be
connected.
1
Free-Run
refreshing
Ver. 1.1
NX-SIH400
8 points
2 points
Sinking
inputs

(PNP)
24 VDC
Cannot be
connected.
1
Free-Run
refreshing
Ver. 1.0
NX-SID800
*1 OMRON special safety input devices refer to devices listed below. These devices can be connected directly to the
     NX-SIH400 without any dedicated controller. Refer to the NX-series Safety Control Unit User's Manual (Cat. No. Z930) for
    details.
Type
Model and corresponding PL and safety category
OMRON Single-beam Safety Sensors
E3ZS
OMRON Non-contact Door Switches *2
D40Z
D40A
OMRON Safety Mats
UM *3, UMA
OMRON Safety Edges
SGE (4-wire connection)
*2 The D41D High-Coded Non-Contact Safety Door Switch, which requires no dedicated controller, can be connected directly to both the NXSIH400 and NX-SID800.
*3 UM series is no longer available for order after June 2019.
Safety Output Units
Unit
type
Ap-
pear-

ance
Specification
Unit
version
Model
Number
of

safety

output

points
Internal
I/O

common
Maximum load
current
Rated
voltage
Number
of safety

slave

con-

nections
I/O re-
freshing
method
Safety
Output

Units
2 points
Sourcing
outputs

(PNP)
2.0 A/point,
4.0 A/Unit at 40°C,

and 2.5 A/

Unit at 55°C

The maximum load

current depends on

the installation

orientation and

ambient temperature.
24 VDC
1
Free-Run
refreshing
Ver. 1.0
NX-SOH200
4 points
Sourcing
outputs

(PNP)
0.5 A/point and
2.0 A/Unit
24 VDC
1
Free-Run
refreshing
Ver. 1.0
NX-SOD400
Accessories
Not included.
Option
Unit/Terminal Block Coding Pins
Product Name
Specification
Model
Unit/Terminal Block Coding Pins
For 10 Units (Terminal Block: 30 pins, Unit: 30 pins)
NX-AUX02
Terminal Block
Product name
Specification
Model
No. of
terminals
Terminal number
indications
Ground terminal
mark
Terminal current
capacity
Terminal Block
8
A/B
None
10A
NX-TBA082
16
A/B
None
10A
NX-TBA162