Size

M8

Sensing distance

Single

Double

Type

Shielded

Unshielded

Shielded

Unshielded

Model

E2B-S08[]S01

E2B-S08[]N02

E2B-S08[]S02

E2B-S08[]N04

Sensing distance

1.5 mm ± 10%

2 mm ± 10%

2 mm ± 10%

4 mm ± 10%

Setting distance

0 to 1.2 mm

0 to 1.6 mm

0 to 1.6 mm

0 to 3.2 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object
 (mild steel ST37)

8 × 8 × 1 mm

8 × 8 × 1 mm

8 × 8 × 1 mm

12 × 12 × 1 mm

Response frequency *1

2,000 Hz

1,000 Hz

1,500 Hz

1,000 Hz

Power supply voltage

10 to 30 VDC. (including 10% ripple (p-p))

Current consumption

10 mA max.

Output type

-B models: PNP open collector
 -C models: NPN open collector

Control
 output

Load current *2

200 mA max. (30 VDC max.)

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation mode (with sensing
 object approaching)

-B1/-C1 models: NO
 -B2/-C2 models: NC

Protection circuit

Output reverse polarity protection, Power source circuit reverse polarity protection,
 Surge suppressor, Short-circuit protection

Ambient air temperature

Operation and storage: -25 to 70°C (with no icing or condensation)

Temperature influence *2

±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
 ±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C

Ambient humidity

Operation and Storage: 35 to 95%

Voltage influence

±1% max. of sensing distance in 24 VDC ±15%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

500 m/s2 , 10 times each in X, Y and Z directions

Standard and listings

(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)

Connecting method

Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
 Connector models (M8-3pin)

Weight
 (packaged)

Pre-wired model

Short body: Approx. 65 g, Long body: Approx. 65 g

Connector model

Short body: Approx. 20 g, Long body: Approx. 20 g

Material

Case

Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).)

Sensing surface

PBT

Cable

Standard cable is 4 mm dia. PVC.

Clamping nut

Brass-nickel plated

Toothed washer

Zinc-plated iron

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
 2. When using any model of M8 size at an ambient temperature between -25°C and 60°C, use a load current of 200 mA
        max., at an ambient temperature between 60°C and 70°C, use a load current of 100 mA max.

Size

M12

Sensing distance

Single

Double

Type

Shielded

Unshielded

Shielded

Unshielded

Model

E2B-M12[]S02

E2B-M12[]N05

E2B-M12[]S04

E2B-M12[]N08

Sensing distance

2 mm ± 10%

5 mm ± 10%

4 mm ± 10%

8 mm ± 10%

Setting distance

0 to 1.6 mm

0 to 4 mm

0 to 3.2 mm

0 to 6.4 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object
 (mild steel ST37)

12 × 12 × 1 mm

15 × 15 × 1 mm

12 × 12 × 1 mm

24 × 24 × 1 mm

Response frequency *1

1,500 Hz

800 Hz

1,000 Hz

800 Hz

Power supply voltage

10 to 30 VDC. (including 10% ripple (p-p))

Current consumption

10 mA max.

Output type

-B models: PNP open collector
 -C models: NPN open collector

Control
 output

Load current

200 mA max. (30 VDC max.)

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation mode (with sensing
 object approaching)

-B1/-C1 models: NO
 -B2/-C2 models: NC

Protection circuit

Output reverse polarity protection, Power source circuit reverse polarity protection,
 Surge suppressor, Short-circuit protection

Ambient air temperature

Operation and storage: -25 to 70°C (with no icing or condensation)

Temperature influence

±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
 ±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C

Ambient humidity

Operation and Storage: 35 to 95%

Voltage influence

±1% max. of sensing distance in 24 VDC ±15%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

1,000 m/s2 , 10 times each in X, Y and Z directions

Standard and listings

(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)

Connecting method

Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
 Connector models (M12-4pin)

Weight
 (packaged)

Pre-wired model

Short body: Approx. 75 g, Long body: Approx. 80 g *2

Connector model

Short body: Approx. 35 g, Long body: Approx. 40 g

Material

Case

Brass-nickel plated

Sensing surface

PBT

Cable

Standard cable is 4 mm dia. PVC.

Clamping nut

Brass-nickel plated

Toothed washer

Zinc-plated iron

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
 2. In case of ‘WP’ cable type. 

Size

M18

Sensing distance

Single

Double

Type

Shielded

Unshielded

Shielded

Unshielded

Model

E2B-M18[]S05

E2B-M18[]N10

E2B-M18[]S08

E2B-M18[]N16

Sensing distance

5 mm ± 10%

10 mm ± 10%

8 mm ± 10%

16 mm ± 10%

Setting distance

0 to 4 mm

0 to 8 mm

0 to 6.4 mm

0 to 12.8 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object
 (mild steel ST37)

18 × 18 × 1 mm

30 × 30 × 1 mm

24 × 24 × 1 mm

48 × 48 × 1 mm

Response frequency *1

600 Hz

400 Hz

500 Hz

400 Hz

Power supply voltage

10 to 30 VDC. (including 10% ripple (p-p))

Current consumption

10 mA max.

Output type

-B models: PNP open collector
 -C models: NPN open collector

Control
 output

Load current

200 mA max. (30 VDC max.)

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation mode (with sensing
 object approaching)

-B1/-C1 models: NO
 -B2/-C2 models: NC

Protection circuit

Output reverse polarity protection, Power source circuit reverse polarity protection,
 Surge suppressor, Short-circuit protection

Ambient air temperature

Operation and storage: -25 to 70°C (with no icing or condensation)

Temperature influence

±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
 ±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C

Ambient humidity

Operation and Storage: 35 to 95%

Voltage influence

±1% max. of sensing distance in 24 VDC ±15%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

1,000 m/s2 , 10 times each in X, Y and Z directions

Standard and listings

(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)

Connecting method

Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
 Connector models (M12-4pin)

Weight
 (packaged)

Pre-wired model

Short body: Approx. 95 g, Long body: Approx. 110 g *2

Connector model

Short body: Approx. 60 g, Long body: Approx. 80 g

Material

Case

Brass-nickel plated

Sensing surface

PBT

Cable

Standard cable is 4 mm dia. PVC.

Clamping nut

Brass-nickel plated

Toothed washer

Zinc-plated iron

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
 2. In case of ‘WP’ cable type. 

Size

M30

Sensing distance

Single

Double

Type

Shielded

Unshielded

Shielded

Unshielded

Model

E2B-M30[]S10

E2B-M30[]N20

E2B-M30[]S15

E2B-M30[]N30

Sensing distance

10 mm ± 10%

20 mm ± 10%

15 mm ± 10%

30 mm ± 10%

Setting distance

0 to 8 mm

0 to 16 mm

0 to 11.25 mm

0 to 22.5 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object
 (mild steel ST37)

30 × 30 × 1 mm

60 × 60 × 1 mm

45 × 45 × 1 mm

90 × 90 × 1 mm

Response frequency *1

400 Hz

100 Hz

250 Hz

100 Hz

Power supply voltage

10 to 30 VDC. (including 10% ripple (p-p))

Current consumption

10 mA max.

Output type

-B models: PNP open collector
 -C models: NPN open collector

Control
 output

Load current

200 mA max. (30 VDC max.)

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation mode (with sensing
 object approaching)

-B1/-C1 models: NO
 -B2/-C2 models: NC

Protection circuit

Output reverse polarity protection, Power source circuit reverse polarity protection,
 Surge suppressor, Short-circuit protection

Ambient air temperature

Operation and storage: -25 to 70°C (with no icing or condensation)

Temperature influence

±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
 ±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C

Ambient humidity

Operation and Storage: 35 to 95%

Voltage influence

±1% max. of sensing distance in 24 VDC ±15%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions

Shock resistance

1,000 m/s2 , 10 times each in X, Y and Z directions

Standard and listings

(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)

Connecting method

Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
 Connector models (M12-4pin)

Weight
 (packaged)

Pre-wired model

Short body: Approx. 160 g, Long body: Approx. 210 g *2

Connector model

Short body: Approx. 140 g, Long body: Approx. 160 g

Material

Case

Brass-nickel plated

Sensing surface

PBT

Cable

Standard cable is 4 mm dia. PVC.

Clamping nut

Brass-nickel plated

Toothed washer

Zinc-plated iron

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
 2. In case of ‘WP’ cable type.