DC 2-Wire (E2FM-X[]D[])

Size

M8

M12

M18

M30

M12

M18

M30

Shielded

Shielded

Model

E2FM-
 X1R5D1-[]

E2FM-
 X2D1-[]

E2FM-
 X5D1-[]

E2FM-
 X10D1[]

E2FM-
 X2D1-
 M1T1GJ-T

E2FM-
 X5D1-
 M1T1GJ-T

E2FM-
 X10D1-
 M1T1GJ-T

Sensing distance

1.5 mm±10%

2 mm
 ±10%

5 mm
 ±10%

10 mm
 ±10%

2 mm±10%

5 mm±10%

10 mm±10%

Set distance

0 to 1.05 mm

0 to
 1.4 mm

0 to
 3.5 mm

0 to
 7 mm

0 to 1.4 mm

0 to 3.5 mm

0 to 7 mm

Differential travel

15% max. of sensing distance

Sensing object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering
 Data on Catalog.)

Standard sensing object

Iron, 8 ×
 8 × 1 mm

Iron, 12
 × 12 ×
 1 mm

Iron, 30
 × 30 ×
 1 mm

Iron, 54
 × 54 ×
 1 mm

Iron, 12 ×
 12 × 1 mm

Iron, 30 ×
 30 × 1 mm

Iron, 54 ×
 54 × 1 mm

Response frequency
 *1

200 Hz

100 Hz

100 Hz

50 Hz

100 Hz

100 Hz

50 Hz

Power supply voltage
 (operating voltage range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Leakage current

0.8 mA max.

Output configuration

With polarity

No polarity

Control
 output

Switching
 capacity

3 to 100 mA

Residual
 voltage

3 V max.
 (Load current: 100 mA max., Cable length: 2 m)

5 V max.
 (Load current: 100 mA max.,
 Cable length: 2 m)

Indicators

Operation indicator (red LED), Setting/Operation indicator (green LED)

Operation mode (with
 sensing object
 approaching)

NO *2

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature
 range

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity
 range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C.

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction:
500 m/s2
 10 times each
 in X, Y, and Z
 directions

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67

Connection method

Unmarked: Pre-wired Models (Standard cable length: 2 m)
 Models ending with -M1GJ-[]: Pre-wired Connector Models (Standard cable length: 300 mm)

Weight
 (packed
 state)

Pre-wired
 Models (2 m)

Approx. 105 g

Approx.
 190 g

Approx.
 215 g

Approx.
 295 g

---

---

---

Pre-wired
 Connector
 Models

Approx. 65 g

Approx.
 85 g

Approx.
 110 g

Approx.
 190 g

Approx. 85 g

Approx. 110 g

Approx. 190 g

Mate-
 rials

Case

Stainless steel (SUS303)

Sensing
 surface
 (thickness)

Stainless steel (SUS303)

(0.4 mm)

(0.8 mm)

(0.8 mm)

Clamping
 nuts

Stainless steel (SUS303)

Cable

PVC (flame retardant)

Toothed
 washer

Zinc-plated iron

Accessories

Instruction manual

1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 2. NC (normally closed) models are also available. Contact your OMRON representative.

DC 3-Wire (E2FM-X[]C[], E2FM-X[]B[])

Size

M8

M12

M18

M30

Shielded

Shielded

Model

E2FM-X1R5[]

E2FM-X2[]

E2FM-X5[]

E2FM-X10[]

Sensing distance

1.5 mm±10%

2 mm±10%

5 mm±10%

10 mm±10%

Set distance

0 to 1.05 mm

0 to 1.4 mm

0 to 3.5 mm

0 to 7 mm

Differential travel

15% max. of sensing distance

Sensing object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Catalog.)

Standard sensing
 object

Iron, 8 × 8 × 1 mm

Iron, 12 × 12 × 1 mm

Iron, 30 × 30 × 1 mm

Iron, 54 × 54 × 1 mm

Response frequency *1

200 Hz

100 Hz

100 Hz

50 Hz

Power supply voltage
 (operating voltage range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Current consumption

10 mA max.

Output configuration

PNP open collector output

Control
 output

Switching
 capacity

200 mA max.

Residual
 voltage

2 V max. (Load current: 200 mA, Cable length: 2 m)

Indicators

Operation indicator (yellow LED)

Operation mode
 (with sensing object
 approaching)

C1 Models: NPN open collector, NO (normally open) *2
 B1 Models: PNP open collector, NO (normally open) *2

Protection circuits

Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed
 output polarity protection (except the E2FM-X1R5B1-M1)

Ambient
 temperature range

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C.

Voltage influence

±1% max. of sensing distance in the rated voltage ±15% range (using the sensing distance at the rated
 voltage as standard)

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s2 10 times each
 in X, Y, and Z directions

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67

Connection method

Unmarked: Pre-wired Models (Standard cable length: 2 m)
 Models ending with -M1: Connector Models

Weight
 (packed
 state)

Pre-wired
 Models (2 m)

---

Approx. 170 g

Approx. 190 g

Approx. 275 g

Pre-wired
 Connector
 Models

Approx. 45 g

Approx. 55 g

Approx. 75 g

Approx. 160 g

Materials

Case

Stainless steel (SUS303)

Sensing
 surface

Stainless steel (SUS303)

(thickness)

(0.4 mm)

(0.8 mm)

Clamping
 nuts

Stainless steel (SUS303)

Toothed
 washer

Zinc-plated iron

Accessories

Instruction manual

1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.