Aluminum-detecting Proximity Sensor
E2EY
A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected.
Model |
E2EY-X4C1 |
E2EY-X8C1 |
|
Sensing distance |
4 mm ±10% |
8 mm ±10% |
|
Set distance |
0 to 2.8 mm |
0 to 5.6 mm |
|
Differential travel |
20% max. of sensing distance |
||
Detectable object |
Non-ferrous metal (Does not detect ferrous metal.) |
||
Standard sensing object |
Aluminum: 18 × 18 × 1 mm |
Aluminum: 30 × 30 × 1 mm |
|
Response frequency * |
70 Hz |
||
Power supply voltage |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
||
Current consumption |
20 mA max. |
||
Control |
Load |
NPN open-collector output, 100 mA max. (at 30 VDC) |
|
Residual |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
||
Indicators |
Detection indicator (red) |
||
Operation mode |
Load ON: NO (Refer to Datasheet.) |
||
Protection circuits |
Reverse polarity protection, Load short-circuit protection, Surge suppressor |
||
Ambient temperature range |
Operating/Storage: -10 to 55°C (with no icing or condensation) |
||
Ambient humidity range |
Operating/Storage: 35% to 95% (with no condensation) |
||
Temperature influence |
±20% max. of sensing distance at 23°C in the temperature range of -10 to 55°C |
||
Voltage influence |
±2.5% max. of sensing distance at rated voltage in rated voltage ±15% range |
||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
||
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||
Shock resistance |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
||
Degree of protection |
IEC 60529 IP67, in-house standards: oil-resistant |
||
Connection method |
Pre-wired Models (Standard cable length: 2 m) |
||
Weight (packed state) |
Approx. 140 g |
Approx. 190 g |
|
Materials |
Case |
Nickel-plated brass |
|
Sensing |
Heat-resistant ABS |
||
Clamping |
Nickel-plated brass |
||
Toothed |
Zinc-plated iron |
||
Accessories |
--- |
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object, and a set distance of half the sensing distance.