Guard Lock Safety Key Selector Switch

A22LK

The guard lock prevents accidental mode changes.

Certified Standards
Certification body
Standards
File No.
UL
UL508, CSA C22.2 No.14
E76675
TÜV SÜD
EN60947-5-1 (certified direct opening)
Consult your OMRON representative for details.
CQC(CCC)
GB/T 14048.5
Consult your OMRON representative for details.
KOSHA
KS C IEC 60947-5-1
Consult your OMRON representative for details.
Note: Only models with NC contacts have a direct opening mechanism.
Certified Standard Ratings
TÜV (EN60947-5-1)
Utilization category
AC-15
DC-13
Rated operating current (Ie)
3 A
0.27 A
Rated operating voltage (Ue)
240 V
250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
          into the Switch.
Solenoid Coil Characteristics
Type
24 VDC
Rated operating voltage (100% ED)
24 VDC ±10%
Current consumption
Approx. 88mA
Insulation
Class A (130°C max.)
Characteristics
Model
A22LK
Allowable operating
frequency
Mechanical
30 operations/minute max.
Electrical
30 operations/minute max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
Between terminals of same polarity
2,500 VAC, 50/60Hz for 1min.
Between each terminal and ground
6,000 VAC, 50/60Hz for 1min.
Vibration resistance *1
10 to 55 Hz, 1.5mm double amplitude (within 1 ms)
Shock resistance
Destruction
1000m/s2
Malfunction *1
300m/s2
Durability
Mechanical
100,000 operations min.
Electrical
100,000 operations min.
Ambient operating temperature *2
-10 to +55°C
Ambient operating humidity
35% to 85%RH
Degree of protection *3
IP65 *3
Electric shock protection class
Class II
Degree of contamination
3 (EN60947-5-1)
Note: 1. Do not allow the load current to exceed the rated value.
             2. The contact ON/OFF timing is not synchronized. Confirm performance before application.

             3. Once the contacts have been used to switch a load, however, they cannot be use
d to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1.
Malfunction within 1 ms.
*2. With no icing or condensation.
*3.
The degree of protection from the front of the panel.