Product Category

Guard Lock Safety Key Selector Switch

A22LK

The guard lock prevents accidental mode changes.

Certified Standards
Certification body
Standards
File No.
UL
UL508, CSA C22.2 No.14
E76675
TÜV SÜD
EN60947-5-1 (certified direct opening)
Consult your OMRON representative for details.
CQC(CCC)
GB/T 14048.5
Consult your OMRON representative for details.
KOSHA
KS C IEC 60947-5-1
Consult your OMRON representative for details.
Note: Only models with NC contacts have a direct opening mechanism.
Certified Standard Ratings
TÜV (EN60947-5-1)
Utilization category
AC-15
DC-13
Rated operating current (Ie)
3 A
0.27 A
Rated operating voltage (Ue)
240 V
250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
          into the Switch.
Solenoid Coil Characteristics
Type
24 VDC
Rated operating voltage (100% ED)
24 VDC ±10%
Current consumption
Approx. 88mA
Insulation
Class A (130°C max.)
Characteristics
Model
A22LK
Allowable operating
frequency
Mechanical
30 operations/minute max.
Electrical
30 operations/minute max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
Between terminals of same polarity
2,500 VAC, 50/60Hz for 1min.
Between each terminal and ground
6,000 VAC, 50/60Hz for 1min.
Vibration resistance *1
10 to 55 Hz, 1.5mm double amplitude (within 1 ms)
Shock resistance
Destruction
1000m/s2
Malfunction *1
300m/s2
Durability
Mechanical
100,000 operations min.
Electrical
100,000 operations min.
Ambient operating temperature *2
-10 to +55°C
Ambient operating humidity
35% to 85%RH
Degree of protection *3
IP65 *3
Electric shock protection class
Class II
Degree of contamination
3 (EN60947-5-1)
Note: 1. Do not allow the load current to exceed the rated value.
             2. The contact ON/OFF timing is not synchronized. Confirm performance before application.

             3. Once the contacts have been used to switch a load, however, they cannot be use
d to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1.
Malfunction within 1 ms.
*2. With no icing or condensation.
*3.
The degree of protection from the front of the panel.