Product Category

Enabling Grip Switch

A4EG

Enabling grip switches are safety components used to prevent unexpected machine operation when workers perform maintenance or other non-routine tasks inside hazardous areas, such as areas inside protective shields.

Standards and EC Directives
Compliance with EC Directives and International Standards
• Low Voltage Directive
• GS-ET-22
Certified Standards
Certifying body
Standard
File No.
TÜV SÜD
EN 60947-5-1 (certified direct opening)
Consult your OMRON representative for details.
UL *
UL 508, CSA C22.2 No.14
E76675
CQC (CCC)
GB/T 14048.5
Consult your OMRON representative for details.
KOSHA
EN60947-5-1
Consult your OMRON representative for details.
* Certification for CSA C22.2 No. 14 by UL is indicated by the
.
Certified Standard Ratings (Enabling Switch Section)
TÜV (EN 60947-5-1)
Utilization category
AC-15
DC-13
Rated operating current (Ie)
0.75 A
0.55 A
Rated operating voltage (Ue)
240 V
125 V
Note: Use a 10-A fuse type gI or gG that conforms to IEC 60269 as the short-circuit protection device.
         The fuse is not built into the Switch.
UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB/T 14048.5)
• 24 VDC, 0.3 A (inductive load)
• 125 VAC, 1 A (resistive load)
Ratings
Section
Enabling switch
Emergency stop switch
(A4EG-BE2R041 only)
Pushbutton
(A4EG-BM2B041 only)
Rated insulation
voltage
250 V
Rated ON current
2.5 A
5 A
0.1 A
Rated load
24 VDC, 0.3 A (inductive load)
125 VAC, 1 A (resistive load)


EN certification rating:

AC-15 0.75 A/240 V

DC-13 0.55 A/125 V
General rating:
125 VAC, 5 A (resistive load)

250 VAC, 3 A (resistive load)

30 VDC, 3 A (resistive load)


UL and
cUL rating:
125 VAC, 5A (inductive load,

power factor: 0.75 to 0.8)

250 VAC, 3 A (inductive load,

power factor: 0.75 to 0.8)

30 VDC, 3 A (resistive load)


EN certification rating:

AC-12 3 A/250 V

DC-12 3 A/30 V
General rating:
125 VAC, 0.1 A (resistive load)

8 VDC, 0.1 A (resistive load)

14 VDC, 0.1 A (resistive load)

30 VDC, 0.1 A (resistive load)


UL and
cUL rating:
125 VAC, 0.1 A (resistive load)

30 VDC, 0.1 A (resistive load)


EN certification rating:

AC-12 0.1 A/125 V

DC-12 0.1 A/30 V
Minimum applicable
load
24 VDC, 4 mA
5 VDC, 1 mA
Characteristics
Section
Enabling switch
Emergency stop switch
(A4EG-BE2R041 only)
Pushbutton
(A4EG-BM2B041 only)
Degree of protection
IP66 (A4EG-C000041), IP65 (A4EG-BE2R041, A4EG-BM2B041)
Operating section strength
Operating direction:
200 N, 1 min
Operating direction: 367 N,
1 min

Rotating direction: 0.49
N·m,
1 min
Operating direction: 50 N,
1 min
Cable pull strength
30 N, 1 min
Allowable
operating

frequency
Electrical
20 operations/minute
max.
10 operations/minute max.
(set/reset for one operation)
60 operations/minute max.
Mechanical
20 operations/minute
max.
10 operations/minute max.
(set/reset for one operation)
120 operations/minute max.
Electrical durability
100,000 operations min.
(rated load)
100,000 operations min.
(set/reset for one operation)

(rated load)
100,000 operations min.
(rated load)
Mechanical durability
OFF-ON-OFF (direct
opening): 100,000

operations min.

OFF-ON: 1,000,000

operations min.
100,000 operations min.
(set/reset for one operation)
2,000,000 operations min.
Dielectric
strength
Between
terminals of the

same polarity
2,500 VAC, 50/60 Hz,
1 minute

(impulse voltage)
1,000 VAC, 50/60 Hz,
1 minute
1,000 VAC, 50/60 Hz,
1 minute
Between
terminals of the

different polarity
2,500 VAC, 50/60 Hz,
1 minute

(impulse voltage)
2,000 VAC, 50/60 Hz,
1 minute
2,000 VAC, 50/60 Hz,
1 minute
Between each
terminal and

non-current

carrying metallic

parts
2,500 VAC, 50/60 Hz,
1 minute

(impulse voltage)
2,000 VAC, 50/60 Hz,
1 minute
2,000 VAC, 50/60 Hz,
1 minute
Insulation resistance
100 MΩ min. (at 500 VDC)
Vibration
resistance
Malfunction
1.5 mm double amplitude, 10 to 55 Hz
Shock
resistance
Malfunction
150 m/s2 max.
Ambient operating
temperature
-10 to 55°C (with no icing or condensation)
Ambient operating humidity
35% to 85%
Ambient storage temperature
-25 to 65°C (with no icing or condensation)
Protection against electric
shock
Class II (double insulation)
Pollution degree
(operating environment)
3 (EN 60947-5-1)
Conditional short-circuit
current
100 A (EN 60947-5-1)
Note: The timing of contact outputs for two or more circuits is not synchronized. Confirm performance before application.