General-purpose Limit Switch

D4A-[]N

The Limit Switch with Better Seal, Shock Resistance, and Strength

Set model number

SPDT, Double-break Switches

Receptacle box

G 1/2 Conduit

Indicator

Without indicator

With neon lamp
 indicator (AC)

With LED
 indicator (DC)

Actuator

Model

Approved
 standards

Model

Approved
 standards

Model

Roller
 lever *1

Standard

 image

D4A-3101N

UL,
 CSA

D4A-3301N

UL,
 CSA

D4A-3E01N

High-
 sensitivity

image

D4A-3102N

UL,
 CSA

D4A-3302N

UL,
 CSA

D4A-3E02N

Low-torque

image

D4A-3103N

UL,
 CSA

---

---

---

High-
 sensitivity,
 Low-
 torque

image

D4A-3104N

UL,
 CSA

D4A-3304N

UL,
 CSA

---

Maintained *2

image

D4A-3105N

UL,
 CSA

D4A-3305N

UL,
 CSA

D4A-3E05N

Side
 plunger

Standard

image

D4A-3106N

UL,
 CSA

---

UL,
 CSA

---

Vertical
 roller

image

D4A-3107-VN

UL,
 CSA

D4A-3307-VN

UL,
 CSA

D4A-3E07-VN

Horizontal
 roller

image

D4A-3107-HN

UL,
 CSA

D4A-3307-HN

UL,
 CSA

---

Adjustable

image

D4A-3108N

UL,
 CSA

D4A-3308N

UL,
 CSA

D4A-3E08N

Top
 plunger

Standard

image

D4A-3109N

UL,
 CSA

D4A-3309N

UL,
 CSA

---

Roller

image

D4A-3110N

UL,
 CSA

D4A-3310N

UL,
 CSA

---

Adjustable

image

D4A-3111N

UL,
 CSA

D4A-3311N

UL,
 CSA

---

Flexible
 rod

Spring wire

image

D4A-3112N

UL,
 CSA

D4A-3312N

UL,
 CSA

D4A-3E12N

Plastic rod

image

D4A-3114N

UL,
 CSA

D4A-3314N

UL,
 CSA

D4A-3E14N

Cat whisker

image

D4A-3115N

UL,
 CSA

D4A-3315N

UL,
 CSA

D4A-3E15N

Coil spring

image

D4A-3116N

UL,
 CSA

D4A-3316N

UL,
 CSA

D4A-3E16N

Note: 1. Switches are also available with []1/2-14 NPT conduits. The model numbers correspond as follows:
               (Examples) G 1/2 Conduits 1/2-14 NPT Conduits
                                     D4A-3[][][]N D4A-1[][][]N
                                     D4A-4[][][]N D4A-2[][][]N
            2. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating  temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-3101N becomes D4A-3101N-F.) Ask your nearest OMRON representative for details. Not all combinations are possible. Ask your OMRON representative for details.
 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on Data Sheet).
 2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock.

DPDT, Double-break Switches

Receptacle box

G 1/2 Conduit

Indicator

Without indicator

With neon lamp
 indicator (AC)

With LED
 ndicator (DC)

Actuator

Model

Approved
 standards

Model

Model

Roller
 lever *1

Standard

image

D4A-4501N

UL,
 CSA

D4A-4L01N

D4A-4P01N

High-
 sensitivity

image

D4A-4502N

UL,
 CSA

---

---

Low-
 torque

image

D4A-4503N

UL,
 CSA

---

---

High-
 sensitivity,
 Low-torque

image

D4A-4504N

UL,
 CSA

---

---

Maintained * 2

image

D4A-4505N

UL,
 CSA

---

---

Sequential
 operation

image

D4A-4717N

UL,
 CSA

---

---

Center neutral
 operation

image

D4A-4918N

UL,
 CSA

---

---

Side
 plunger

Standard

image

D4A-4506N

UL,
 CSA

---

---

Vertical roller

image

D4A-4507-VN

UL,
 CSA

---

---

Horizontal roller

image

D4A-4507-HN

UL,
 CSA

---

---

Adjustable

image

D4A-4508N

UL,
 CSA

---

---

Top
 plunger

Standard

image

D4A-4509N

UL,
 CSA

---

---

Roller

image

D4A-4510N

UL,
 CSA

D4A-4L10N

D4A-4P10N

Adjustable

image

D4A-4511N

UL,
 CSA

---

---

Flexible
 rod

Spring wire

image

D4A-4512N

UL,
 CSA

---

---

Plastic rod

image

D4A-4514N

UL,
 CSA

---

---

Cat whisker

image

D4A-4515N

UL,
 CSA

---

---

Coil spring

image

D4A-4516N

UL,
 CSA

---

---

Note: 1. Switches are also available with []1/2-14 NPT conduits. The model numbers correspond as follows:
               (Examples) G 1/2 Conduits 1/2-14 NPT Conduits
                                     D4A-3[][][]N D4A-1[][][]N
                                     D4A-4[][][]N D4A-2[][][]N
           2. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest OMRON representative about delivery times and prices.
 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on Data Sheet).
 2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock.

Individual Parts

Receptacle box

Type

G1/2 conduit * 1

1/2-14NPT conduit * 2

Appearance

Model

Approved standards

Model

Approved standards

SPDT double-break

image

D4A-3000N

UL, CSA

D4A-1000N

UL, CSA

DPDT double-break

image

D4A-4000N

UL, CSA

D4A-2000N

UL, CSA

1. M6-screw mounting (standard mounting)
 2. 10-32UNF-screw mounting (standard mounting) 

Switch Box

Indicator

Without
 indicator

With neon lamp
 indicator (AC)

With LED
 indicator (DC)

Appearance

Model

Approved
 standards

Model

Approved
 standards

Model

SPDT
 double-break

image
 (Without indicator lamp)

D4A-0100N

UL,
 CSA

D4A-0300N

UL,
 CSA

D4A-0E00N

DPDT
 double-break

image
 (Without indicator lamp)

Simultaneous
 operation

D4A-0500N

UL,
 CSA

D4A-0L00N

---

D4A-0P00N

Sequential
 operation

D4A-0700N

UL,
 CSA

---

---

---

Center neutral
 operation

D4A-0900N

UL,
 CSA

---

---

---

Heads

Appearance

Model

Approved standards

Roller lever * 1

image

Standard

D4A-0001N

UL, CSA

High-sensitivity

D4A-0002N

UL, CSA

Low-torque * 2

D4A-0003N

UL, CSA

Sequential operation: * 3

D4A-0017N

UL, CSA

Center neutral operation: * 3

D4A-0018N

UL, CSA

image

Maintained

D4A-0005N

UL, CSA

Side plunger

image

Standard

D4A-0006N

UL, CSA

image

Vertical roller

D4A-0007-VN

UL, CSA

image

Horizontal roller

D4A-0007-HN

UL, CSA

image

Side adjustable

D4A-0008N

UL, CSA

1. Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on Data Sheet).
 2. The D4A-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result.
 3. These heads cannot be used for double break operations.

Appearance

Type

Model

Approved standards

Top plunger

image

Standard

D4A-0009N

UL, CSA

image

Roller

D4A-0010N

UL, CSA

image

Adjustable

D4A-0011N

UL, CSA

Flexible rod

image

Spring wire

D4A-0012N

UL, CSA

image

Plastic rod

D4A-0014N

UL, CSA

image

Cat whisker

D4A-0015N

UL, CSA

image

Coil spring

D4A-0016N

UL, CSA

Levers

Actuator

Model

Roller Lever

D4A-A00

D4A-A10

D4A-A20

D4A-A30

D4A-B06

Adjustable Roller Lever

D4A-C00

D4A-D00

Resin Loop Lever

D4A-F00

Fork Lever Lock

D4A-E30

D4A-E20

D4A-E10

D4A-E00

Note: Refer to Dimensions for Lever shapes and applicable models.