Cylindrical Proximity Sensor
E2A
Safe Mounting with Greater Sensing Distance
DC 3-wire Models
Size |
M8 |
M12 |
|||
Type |
Shielded |
Non-shielded |
Shielded |
Non-shielded |
|
E2A-M08[]S02-M1-B1/B2/C1/C2 |
E2A-M08[]N04-M1-B1/B2/C1/C2 |
E2A-M12[]S04-[][]-B1/B2/C1/C2 |
E2A-M12[]N08-[][]-B1/B2/C1/C2 |
||
Sensing distance |
2 mm ± 10% |
4 mm ± 10% |
4 mm ± 10% |
8 mm ± 10% |
|
Setting distance |
0 to 1.6 mm |
0 to 3.2 mm |
0 to 3.2 mm |
0 to 6.4 mm |
|
Differential travel |
10% max. of sensing distance |
||||
Target |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
||||
Standard target |
8×8×1 mm |
12×12×1 mm |
12×12×1 mm |
24×24×1 mm |
|
Response frequency |
1,500 Hz |
1,000 Hz |
1,000 Hz |
800 Hz |
|
Power supply voltage |
12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) |
||||
Current consumption |
10 mA max. |
||||
Output type |
-B models: PNP open collector |
||||
Control |
Load |
200 mA max. (32 VDC max.) |
|||
Residual |
2 V max. (under load current of 200 mA with cable length of 2 m) |
||||
Indicator |
Operation indicator (Yellow LED) |
||||
Operation mode |
-B1/-C1 models: NO |
||||
Protection circuit |
Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
|||
Ambient air |
Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation) |
||||
Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C |
||||
Ambient humidity |
Operating: 35% to 95%, Storage: 35% to 95% |
||||
Voltage influence |
±1% max. of sensing distance in rated voltage range ±15% |
||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current carry parts and case |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case |
||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance |
500 m/s2, 10 times each in X, Y and Z directions |
1,000 m/s2, 10 times each in X, Y and Z directions |
|||
Standard and listings |
IEC60529: IP67, Degree of protection |
||||
Connection method |
-WP models: Pre-wired models (Standard length: 2 m) |
||||
Weight |
Pre-wired |
Approx. 65 g |
Approx. 85 g |
||
M12 |
M12 connector models: Approx. 20 g |
Approx. 35 g |
|||
Material |
Case |
Stainless steel or brass-nickel plated |
Brass-nickel plated |
||
Sensing |
PBT |
||||
Cable |
PVC |
||||
Clamping |
Brass-nickel plated |
1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.,
3. For USA and CANADA : use class 2 circuit only.
Size |
M18 |
M30 |
||||
Type |
Shielded |
Non-shielded |
Shielded |
Non-shielded |
Non-shielded |
|
E2A-M18[]S08-[][]-B1/B2/C1/C2 |
E2A-M18[]N16-[][]-B1/B2/C1/C2 |
E2A-M30[]S15-[][]-B1/B2/C1/C2 |
E2A-M30KN20-[][]-B1/B2/C1/C2 |
E2A-M30LN30-[][]-B1/B2/C1/C2 |
||
Sensing distance |
8 mm±10% |
16 mm±10% |
15 mm±10% |
20 mm±10% |
30 mm±10% |
|
Setting distance |
0 to 6.4 mm |
0 to 12.8 mm |
0 to 12 mm |
0 to 16 mm |
0 to 24 mm |
|
Differential travel |
10% max. of sensing distance |
|||||
Target |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
|||||
Standard target |
24×24×1 mm |
48×48×1 mm |
45×45×1 mm |
60×60×1 mm |
90×90×1 mm |
|
Response frequency |
500 Hz |
400 Hz |
250 Hz |
100 Hz |
100 Hz |
|
Power supply voltage |
12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) |
|||||
Current consumption |
10 mA max. |
|||||
Output type |
-B models: PNP open collector |
|||||
Control |
Load |
200 mA max. (32 VDC max.) |
||||
Residual |
2 V max. (under load current of 200 mA with cable length of 2 m) |
|||||
Indicator |
Operation indicator (Yellow LED) |
|||||
Operation mode |
-B1/-C1 models: NO |
|||||
Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
|||||
Ambient air |
Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation) |
|||||
Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C |
|||||
Ambient humidity |
Operating: 35% to 95%, Storage: 35% to 95% |
|||||
Voltage influence |
±1% max. of sensing distance in rated voltage range ±15% |
|||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current carry parts and case |
|||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case |
|||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
|||||
Shock resistance |
1,000 m/s2, 10 times each in X, Y and Z directions |
|||||
Standard and listings |
IEC60529: IP67, Degree of protection |
|||||
Connection method |
-WP models: Pre-wired models (Standard length: 2 m) |
|||||
Weight |
Pre-wired |
Approx. 160 g |
Approx. 280 g |
Approx. 280 g |
Approx. 370 g |
|
M12 |
Approx. 70 g |
Approx. 200 g |
Approx. 200 g |
Approx. 260 g |
||
Material |
Case |
Brass-nickel plated |
||||
Sensing |
PBT |
|||||
Cable |
PVC |
|||||
Clamping |
Brass-nickel plated |
1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.
3. For USA and CANADA : use class 2 circuit only.