Cylindrical Proximity Sensor
E2B
Perfect fit for standard environments
Size |
M8 |
||||
Sensing distance |
Single |
Double |
|||
Type |
Shielded |
Unshielded |
Shielded |
Unshielded |
|
Model |
E2B-S08[]S01 |
E2B-S08[]N02 |
E2B-S08[]S02 |
E2B-S08[]N04 |
|
Sensing distance |
1.5 mm ± 10% |
2 mm ± 10% |
2 mm ± 10% |
4 mm ± 10% |
|
Setting distance |
0 to 1.2 mm |
0 to 1.6 mm |
0 to 1.6 mm |
0 to 3.2 mm |
|
Differential travel |
10% max. of sensing distance |
||||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
||||
Standard sensing object |
8 × 8 × 1 mm |
8 × 8 × 1 mm |
8 × 8 × 1 mm |
12 × 12 × 1 mm |
|
Response frequency *1 |
2,000 Hz |
1,000 Hz |
1,500 Hz |
1,000 Hz |
|
Power supply voltage |
10 to 30 VDC. (including 10% ripple (p-p)) |
||||
Current consumption |
10 mA max. |
||||
Output type |
-B models: PNP open collector |
||||
Control |
Load current *2 |
200 mA max. (30 VDC max.) |
|||
Residual voltage |
2 V max. (under load current of 200 mA with cable length of 2 m) |
||||
Indicator |
Operation indicator (Yellow LED) |
||||
Operation mode (with sensing |
-B1/-C1 models: NO |
||||
Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, |
||||
Ambient air temperature |
Operation and storage: -25 to 70°C (with no icing or condensation) |
||||
Temperature influence *2 |
±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C |
||||
Ambient humidity |
Operation and Storage: 35 to 95% |
||||
Voltage influence |
±1% max. of sensing distance in 24 VDC ±15% |
||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance |
500 m/s2 , 10 times each in X, Y and Z directions |
||||
Standard and listings |
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2) |
||||
Connecting method |
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). |
||||
Weight |
Pre-wired model |
Short body: Approx. 65 g, Long body: Approx. 65 g |
|||
Connector model |
Short body: Approx. 20 g, Long body: Approx. 20 g |
||||
Material |
Case |
Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).) |
|||
Sensing surface |
PBT |
||||
Cable |
Standard cable is 4 mm dia. PVC. |
||||
Clamping nut |
Brass-nickel plated |
||||
Toothed washer |
Zinc-plated iron |
1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
2. When using any model of M8 size at an ambient temperature between -25°C and 60°C, use a load current of 200 mA
max., at an ambient temperature between 60°C and 70°C, use a load current of 100 mA max.
Size |
M12 |
||||
Sensing distance |
Single |
Double |
|||
Type |
Shielded |
Unshielded |
Shielded |
Unshielded |
|
Model |
E2B-M12[]S02 |
E2B-M12[]N05 |
E2B-M12[]S04 |
E2B-M12[]N08 |
|
Sensing distance |
2 mm ± 10% |
5 mm ± 10% |
4 mm ± 10% |
8 mm ± 10% |
|
Setting distance |
0 to 1.6 mm |
0 to 4 mm |
0 to 3.2 mm |
0 to 6.4 mm |
|
Differential travel |
10% max. of sensing distance |
||||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
||||
Standard sensing object |
12 × 12 × 1 mm |
15 × 15 × 1 mm |
12 × 12 × 1 mm |
24 × 24 × 1 mm |
|
Response frequency *1 |
1,500 Hz |
800 Hz |
1,000 Hz |
800 Hz |
|
Power supply voltage |
10 to 30 VDC. (including 10% ripple (p-p)) |
||||
Current consumption |
10 mA max. |
||||
Output type |
-B models: PNP open collector |
||||
Control |
Load current |
200 mA max. (30 VDC max.) |
|||
Residual voltage |
2 V max. (under load current of 200 mA with cable length of 2 m) |
||||
Indicator |
Operation indicator (Yellow LED) |
||||
Operation mode (with sensing |
-B1/-C1 models: NO |
||||
Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, |
||||
Ambient air temperature |
Operation and storage: -25 to 70°C (with no icing or condensation) |
||||
Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C |
||||
Ambient humidity |
Operation and Storage: 35 to 95% |
||||
Voltage influence |
±1% max. of sensing distance in 24 VDC ±15% |
||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance |
1,000 m/s2 , 10 times each in X, Y and Z directions |
||||
Standard and listings |
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2) |
||||
Connecting method |
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). |
||||
Weight |
Pre-wired model |
Short body: Approx. 75 g, Long body: Approx. 80 g *2 |
|||
Connector model |
Short body: Approx. 35 g, Long body: Approx. 40 g |
||||
Material |
Case |
Brass-nickel plated |
|||
Sensing surface |
PBT |
||||
Cable |
Standard cable is 4 mm dia. PVC. |
||||
Clamping nut |
Brass-nickel plated |
||||
Toothed washer |
Zinc-plated iron |
1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
2. In case of ‘WP’ cable type.
Size |
M18 |
||||
Sensing distance |
Single |
Double |
|||
Type |
Shielded |
Unshielded |
Shielded |
Unshielded |
|
Model |
E2B-M18[]S05 |
E2B-M18[]N10 |
E2B-M18[]S08 |
E2B-M18[]N16 |
|
Sensing distance |
5 mm ± 10% |
10 mm ± 10% |
8 mm ± 10% |
16 mm ± 10% |
|
Setting distance |
0 to 4 mm |
0 to 8 mm |
0 to 6.4 mm |
0 to 12.8 mm |
|
Differential travel |
10% max. of sensing distance |
||||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
||||
Standard sensing object |
18 × 18 × 1 mm |
30 × 30 × 1 mm |
24 × 24 × 1 mm |
48 × 48 × 1 mm |
|
Response frequency *1 |
600 Hz |
400 Hz |
500 Hz |
400 Hz |
|
Power supply voltage |
10 to 30 VDC. (including 10% ripple (p-p)) |
||||
Current consumption |
10 mA max. |
||||
Output type |
-B models: PNP open collector |
||||
Control |
Load current |
200 mA max. (30 VDC max.) |
|||
Residual voltage |
2 V max. (under load current of 200 mA with cable length of 2 m) |
||||
Indicator |
Operation indicator (Yellow LED) |
||||
Operation mode (with sensing |
-B1/-C1 models: NO |
||||
Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, |
||||
Ambient air temperature |
Operation and storage: -25 to 70°C (with no icing or condensation) |
||||
Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C |
||||
Ambient humidity |
Operation and Storage: 35 to 95% |
||||
Voltage influence |
±1% max. of sensing distance in 24 VDC ±15% |
||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance |
1,000 m/s2 , 10 times each in X, Y and Z directions |
||||
Standard and listings |
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2) |
||||
Connecting method |
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). |
||||
Weight |
Pre-wired model |
Short body: Approx. 95 g, Long body: Approx. 110 g *2 |
|||
Connector model |
Short body: Approx. 60 g, Long body: Approx. 80 g |
||||
Material |
Case |
Brass-nickel plated |
|||
Sensing surface |
PBT |
||||
Cable |
Standard cable is 4 mm dia. PVC. |
||||
Clamping nut |
Brass-nickel plated |
||||
Toothed washer |
Zinc-plated iron |
1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
2. In case of ‘WP’ cable type.
Size |
M30 |
||||
Sensing distance |
Single |
Double |
|||
Type |
Shielded |
Unshielded |
Shielded |
Unshielded |
|
Model |
E2B-M30[]S10 |
E2B-M30[]N20 |
E2B-M30[]S15 |
E2B-M30[]N30 |
|
Sensing distance |
10 mm ± 10% |
20 mm ± 10% |
15 mm ± 10% |
30 mm ± 10% |
|
Setting distance |
0 to 8 mm |
0 to 16 mm |
0 to 11.25 mm |
0 to 22.5 mm |
|
Differential travel |
10% max. of sensing distance |
||||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
||||
Standard sensing object |
30 × 30 × 1 mm |
60 × 60 × 1 mm |
45 × 45 × 1 mm |
90 × 90 × 1 mm |
|
Response frequency *1 |
400 Hz |
100 Hz |
250 Hz |
100 Hz |
|
Power supply voltage |
10 to 30 VDC. (including 10% ripple (p-p)) |
||||
Current consumption |
10 mA max. |
||||
Output type |
-B models: PNP open collector |
||||
Control |
Load current |
200 mA max. (30 VDC max.) |
|||
Residual voltage |
2 V max. (under load current of 200 mA with cable length of 2 m) |
||||
Indicator |
Operation indicator (Yellow LED) |
||||
Operation mode (with sensing |
-B1/-C1 models: NO |
||||
Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, |
||||
Ambient air temperature |
Operation and storage: -25 to 70°C (with no icing or condensation) |
||||
Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C |
||||
Ambient humidity |
Operation and Storage: 35 to 95% |
||||
Voltage influence |
±1% max. of sensing distance in 24 VDC ±15% |
||||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance |
1,000 m/s2 , 10 times each in X, Y and Z directions |
||||
Standard and listings |
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2) |
||||
Connecting method |
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). |
||||
Weight |
Pre-wired model |
Short body: Approx. 160 g, Long body: Approx. 210 g *2 |
|||
Connector model |
Short body: Approx. 140 g, Long body: Approx. 160 g |
||||
Material |
Case |
Brass-nickel plated |
|||
Sensing surface |
PBT |
||||
Cable |
Standard cable is 4 mm dia. PVC. |
||||
Clamping nut |
Brass-nickel plated |
||||
Toothed washer |
Zinc-plated iron |
1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance.
2. In case of ‘WP’ cable type.