Product Category

E2E

DC 2-Wire (PUR Cable/Self-diagnosis Output), AC 2-Wire and AC/DC 2-Wire

E2E

Models with DC 2-Wire (Self-diagnosis Output) and AC 2-Wire added to the lineup

DC 2-Wire (E2E-X[]D[])

Size

M8

M12

Shielded

Shielded

Shielded

Unshielded

Model

E2E-X2D[]

E2E-X3D[]

E2E-X8MD[]

Sensing distance

2 mm ±10%

3 mm ±10%

8 mm ±10%

Set distance *1

0 to 1.6 mm

0 to 2.4 mm

0 to 6.4 mm

Differential travel

15% max. of sensing distance

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Data Sheet.)

Standard sensing object

Iron,
 8 × 8 × 1 mm

Iron,
 12 × 12 × 1 mm

Iron,
 30 × 30 × 1 mm

Response frequency *2

1.5 kHz


0.8 kHz

Power supply voltage
 (operating voltage range)

12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)

Leakage current

0.8 mA max.

Control
 output

Load current

3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models

Residual
 voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red) and setting indicator (green)
 D2 Models: Operation indicator (red)

Operation mode
 (with sensing object
 approaching)

D1 Models: NO
 D2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Diagnostic output delay

0.3 to 1 s

Protection circuits

Surge suppressor, Load short-circuit protection (for control and diagnostic output)

Ambient temperature
 range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating/storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C
 in the temperature range of -25 to 70°C

±10% max. of sensing distance at 23°C in
 the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1000 VAC, 50/60 Hz for 1 minute between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 500 m/s2 10 times each in X,
 Y, and Z directions

Destruction: 1,000 m/s2 10 times each in X,
 Y, and Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
 Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
 Connector Models (Standard cable length: 0.3 m)

Weight
 (packed
 state)

Pre-wired
 Models

Approx. 60 g

Approx. 70 g

Pre-wired
 Connector
 Models

---

Approx. 40 g
 (Shielded Models only)

Connector
 Models

Approx. 15 g

Approx. 25 g

Materi-
 als

Case

Stainless steel (SUS303)

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

Size

M18

M30

Shielded

Shielded

Unshielded

Shielded

Unshielded

Model

E2E-X7D[]

E2E-X14MD[]

E2E-X10D[]

E2E-X20MD[]

Sensing distance

7 mm ±10%

14 mm ±10%

10 mm ±10%

20 mm ±10%

Set distance *1

0 to 5.6 mm

0 to 11.2 mm

0 to 8 mm

0 to 16 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Data Sheet.)

Standard sensing object

Iron,
 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Iron,
 54 × 54 × 1 mm

Response frequency *2

0.5 kHz

0.4 kHz

0.1 kHz

Power supply voltage
 (operating voltage range)

12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)

Leakage current

0.8 mA max.

Control
 output

Load current

3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models

Residual
 voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red) and setting indicator (green)
 D2 Models: Operation indicator (red)

Operation mode
 (with sensing object
 approaching)

D1 Models: NO
 D2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Diagnostic output delay

0.3 to 1 s

Protection circuits

Surge suppressor, Load short-circuit protection (for control and diagnostic output)

Ambient temperature
 range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating/storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1000 VAC, 50/60 Hz for 1 minute between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
 Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
 Connector Models (Standard cable length: 0.3 m)

Weight
 (packed
 state)

Pre-wired
 Models

Approx. 130 g

Approx. 175 g

Pre-wired
 Connector
 Models

---

---

Connector
 Models

Approx. 40 g

Approx. 90 g

Materi-
 als

Case

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual








1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
 2. The response frequency is an average value.
        Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,
        and a set distance of half the sensing distance. 

AC 2-Wire (E2E-X[]Y[])

Size

M8

M12

Shielded

Shielded

Unshielded

Shielded

Unshielded

Model

E2E-X1R5Y[]

E2E-X2MY[]

E2E-X2Y[]

E2E-X5MY[]

Sensing distance

1.5 mm ±10%

2 mm ±10%

5 mm ±10%

Set distance

0 to 1.2 mm

0 to 1.6 mm

0 to 4 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Data Sheet.)

Standard sensing object

Iron,
 8 × 8 × 1 mm

Iron, 12 × 12 × 1 mm

Iron,
 15 × 15 × 1 mm

Response frequency

25 Hz

Power supply voltage
 (operating voltage range) *1

24 to 240 VAC (20 to 264 VAC), 50/60 Hz

Leakage current

1.7 mA max.

Control
 output

Load current *2

5 to 100 mA

5 to 200 mA

Residual voltage

Refer to Engineering Data on Data Sheet.

Indicators

Operation indicator (red)

Operation mode
 (with sensing object
 approaching)

Y1 Models: NO
 Y2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Protection circuits

Surge suppressor

Ambient temperature range
 *1 *2

Operating/Storage: -25 to 70°C
 (with no icing or condensation)

Operating/Storage: -40 to 85°C
 (with no icing or condensation)

Ambient humidity range

Operating/storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C
 in the temperature range of -25 to 70°C

±15% max. of sensing distance at 23°C
 in the temperature range of -40 to 85°C,
 ±10% max. of sensing distance at 23°C
 in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
 parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 500 m/s2 10 times each in
 X, Y, and Z directions

Destruction: 1,000 m/s2 10 times each
 in X, Y, and Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
 Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) and Connector Models

Weight
 (packed
 state)

Pre-wired Models
 Model

Approx. 60 g

Approx. 70 g

Connector Models

Approx. 15 g

Approx. 25 g

Materials

Case

Stainless steel (SUS303)

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

Size

M18

M30

Shielded

Shielded

Unshielded

Shielded

Unshielded

Model

E2E-X5Y[]

E2E-X10MY[]

E2E-X10Y[]

E2E-X18MY[]

Sensing distance

5 mm ±10%

10 mm ±10%

18 mm ±10%

Set distance

0 to 4 mm

0 to 8 mm

0 to 14 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Data Sheet.)

Standard sensing object

Iron,
 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Iron,
 54 × 54 × 1 mm

Response frequency

25 Hz

Power supply voltage
 (operating voltage range) *1

24 to 240 VAC (20 to 264 VAC), 50/60 Hz

Leakage current

1.7 mA max.

Control
 output

Load current *2

5 to 300 mA

Residual voltage

Refer to Engineering Data on Data Sheet.

Indicators

Operation indicator (red)

Operation mode
 (with sensing object
 approaching)

Y1 Models: NO
 Y2 Models: NC
 Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Protection circuits

Surge suppressor

Ambient temperature range
 *1 *2

Operating/Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating/storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C,
 ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
 parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
 Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m) and Connector Models

Weight
 (packed
 state)

Pre-wired Models
 Model

Approx. 130 g

Approx. 175 g

Connector Models

Approx. 40 g

Approx. 90 g

Materials

Case

Stainless steel (SUS303)

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at
        least −25°C.
 2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the
        Sensor has a control output (load current) of 5 to 200 mA max. 

AC/DC 2-Wire (E2E-X[]T1)

Size

M12

M18

M30

Shielded

Shielded

Model

E2E-X3T1

E2E-X7T1

E2E-X10T1

Sensing distance

3 mm ±10%

7 mm ±10%

10 mm ±10%

Set distance

0 to 2.4 mm

0 to 5.6 mm

0 to 8 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
 Engineering Data on Data Sheet.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron, 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Response
 frequency
 *1

DC

1 kHz

0.5 kHz

0.4 kHz

AC

25 Hz

Power supply voltage
 (operating voltage range) *2

24 to 240 VDC (20 to 264 VDC)
 48 to 240 VAC (40 to 264 VAC)

Leakage current

DC: 1 mA max.
 AC: 2 mA max.

Control
 output

Load current

5 to 100 mA

Residual
 voltage

DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
 AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)

Indicators

Operation indicator (red), Setting indicator (green)

Operation mode
 (with sensing object
 approaching)

NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.)

Protection circuits

Load short-circuit protection (20 to 40 VDC only), Surge suppressor

Ambient temperature range

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant

Connection method

Pre-wired Models (Standard cable length: 2 m)

Weight (packed state)

Approx. 80 g

Approx. 140 g

Approx. 190 g

Materials

Case

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Accessories

Instruction manual

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
        distance of twice the standard sensing object, and a set distance of half the sensing distance.
 2. Power Supply Voltage Waveform:
        Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.